Shield Pressure Gauge 0–600 psi SD-P3 — UL

                                • Primary Purpose: Provides accurate, real-time visual monitoring of water or air pressure across fire pump discharge manifolds, sprinkler risers, and alarm check valves.

                                • Key Specifications: 0–600 PSI pressure range, 3-1/2″ (90 mm) dial face, Bourdon-tube sensing mechanism, and UL 393 Listed for fire protection service.

                                • Customer Benefits: Enables instant pressure verification during routine inspections, prevents undetected system pressure drops, and ensures strict code compliance.

                                • Bangladesh Market Relevance: Trusted across RMG textile factories, pharmaceutical plants, and high-rise commercial towers in Bangladesh requiring UL/NFPA-compliant fire safety audits.

Best Price Guaranteed

Description

Product Overview

What is this product? The Shield SD-P3 is a heavy-duty, Bourdon-tube indicating pressure gauge engineered specifically for fire sprinkler, standpipe, and fire pump systems, featuring a clear 0–600 PSI graduated dial.

How does it work? Inside the gauge, system water or air pressure enters a C-shaped bronze Bourdon tube. As internal pressure increases, the curved tube tends to straighten, transferring precise mechanical motion through a brass movement assembly to rotate the pointer across the 3-1/2″ dial face.

Who needs this product? Fire protection contractors, MEP engineers, factory maintenance teams, and building facility managers installing or servicing fire pump rooms, wet/dry alarm valves, and zone control assemblies.

Why is it useful in Bangladesh? Industrial plants, garment factories, and commercial complexes in Dhaka, Gazipur, Chattogram, and Narayanganj must maintain visible, calibrated pressure gauges at critical system points to pass BNBC, NFPA 13, NFPA 20, and RSC/Accord fire safety inspections. The Shield SD-P3 (UK origin) delivers the high-range 0–600 PSI readability needed for high-pressure fire pump discharge lines and hydrostatic testing.

Key Features

  • UL Listed Certification: Certified to UL 393 standards specifically for indicating pressure gauges used in fire protection service.

  • High-Pressure 0–600 PSI Range: Ideal for high-head fire pump discharge lines, pressure-reducing valve (PRV) inlets, and high-rise standpipe risers.

  • 3-1/2″ Easy-Read Dial: Large white dial face with crisp black graduations ensures clear visibility even in dimly lit pump rooms.

  • Corrosion-Resistant Construction: Features a durable stainless steel case and bezel paired with a bronze Bourdon tube and brass wetted parts for long-term water/air service.

  • Standard Bottom Stem Connection: Designed for straightforward vertical mounting on gauge cocks, test manifolds, and alarm valve trim.

Technical Advantages

  • Reliable Mechanical Accuracy: Calibrated Bourdon-tube movement provides dependable readings without requiring batteries or external electrical power.

  • Vibration & Surge Tolerance: Built to withstand the pressure pulsations common during fire pump startup and weekly churn testing.

  • Long Service Life in Humid Environments: Stainless steel exterior housing resists rust and moisture buildup inside enclosed pump houses.

  • Zero-Maintenance Operation: Hermetically protected dial window keeps dust and condensation off the scale markings for years of clear reading.

Applications

  • Fire Pump Rooms: Installed on the discharge side of electric and diesel-driven centrifugal fire pumps.

  • Sprinkler & Standpipe Risers: Mounted above and below alarm check valves, deluge valves, and zone control assemblies.

  • RMG & Industrial Facilities: Garment factories, spinning mills, chemical warehouses, and power plants across Bangladesh.

  • Commercial High-Rises: Office towers, hospitals, shopping malls, and hotels utilizing high-pressure fire suppression networks.

Why Choose This Product?

  • Recognized UK Fire Brand: Shield fire protection instruments are widely specified by consultants and approved for major industrial projects across Bangladesh.

  • Audit-Ready UL Listing: Eliminates compliance delays during third-party fire safety inspections and factory audits.

  • Extended 600 PSI Scale: Prevents needle over-ranging on high-pressure pump systems where standard 300 PSI gauges fall short.

  • Local Supply & Support: Sourced and supported in Bangladesh through Loop Engineering & Loop Shop with fast nationwide delivery.

4. Technical Specification Table

Specification Details
Model SD-P3
Brand Shield
Country of Origin United Kingdom (UK)
Pressure Range 0–600 PSI
Dial Size 3-1/2 Inch (90 mm)
Certification UL Listed (UL 393 — Fire Protection Service)
Sensing Element C-Shaped Bronze Bourdon Tube
Case & Bezel Material Corrosion-Resistant Stainless Steel
Connection Type 1/4″ NPT / BSP Male Bottom Connection
Service Media Water and Air (Fire Sprinkler & Pump Systems)
Dial Face White Background with High-Contrast Black Scale

5. Features List

  • ✓ UL Listed (UL 393) for fire sprinkler and pump systems

  • ✓ Wide 0–600 PSI measurement range for high-pressure lines

  • ✓ Large 3-1/2″ (90 mm) dial for quick, clear reading

  • ✓ Corrosion-resistant stainless steel casing

  • ✓ Precision bronze Bourdon tube and brass wetted parts

  • ✓ Suitable for both water and air pressure monitoring

  • ✓ Standard threaded bottom mount for easy manifold installation

6. Benefits For Customers

  • Instant System Diagnostics: Lets maintenance engineers verify static and residual fire line pressure at a glance.

  • Protects Against Over-Pressurization: Helps operators detect abnormal pump discharge spikes or PRV malfunctions before pipe joints or sprinklers fail.

  • Passes Fire Safety Inspections: Carries official UL Listing required by NFPA 13, NFPA 20, and Bangladesh industrial compliance auditors.

  • Built for Local Pump Rooms: Resists humidity, condensation, and corrosion in industrial facilities across Dhaka, Gazipur, and Chattogram.

7. Installation & Maintenance Guide

Installation Requirements:

  • Always install the gauge with a UL-listed 3-way gauge cock (isolation/test valve) so the gauge can be isolated, vented, or replaced without draining the fire riser.

  • Apply PTFE thread tape or approved pipe sealant to the male threads and tighten using a wrench on the square brass shank—never twist the gauge case by hand.

  • Mount upright for optimal readability and accurate Bourdon-tube calibration.

Maintenance Tips:

  • Record gauge readings during weekly fire pump and sprinkler riser inspections to spot gradual pressure loss or needle sticking.

  • Verify that the pointer returns cleanly to zero when pressure is bled through the 3-way gauge cock.

  • Replace any gauge immediately if the lens is cracked, fogged internally, or showing more than 3% variance against a calibrated master test gauge.

Safety Instructions:

  • Close the gauge isolation valve and bleed trapped pressure before removing or servicing the gauge.

  • Do not exceed the maximum 600 PSI scale limit during hydrostatic pipe testing; isolate lower-rated gauges before high-pressure line tests.

8. FAQ Section

Q: What is the price of Shield Pressure Gauge 0–600 psi SD-P3 in Bangladesh? A: The price of the Shield SD-P3 0–600 PSI UL Listed Pressure Gauge in Bangladesh depends on order quantity and current stock. Contact loopshop.com.bd directly for the latest BDT unit price or bulk project quotation.

Q: Where can I buy Shield Pressure Gauge 0–600 psi SD-P3 in Bangladesh? A: You can order genuine Shield UL Listed pressure gauges online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial zones in Bangladesh.

Q: What warranty does this product have? A: This gauge includes a standard manufacturer defect warranty backed by Loop Shop. Contact our team with your project specifications for full warranty details.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its stainless steel casing and bronze Bourdon-tube internals are engineered to withstand high humidity, warm pump rooms, and continuous water service in Bangladesh.

Q: How to install this product? A: Thread the bottom stem into a 1/4″ gauge cock on your fire pump manifold or sprinkler riser using thread sealant, tightening only with a wrench on the hex shank—never by turning the outer dial housing.

Q: Why should I choose a 0–600 PSI gauge instead of a 0–300 PSI gauge? A: Per NFPA 13 and NFPA 20 guidelines, a pressure gauge’s maximum scale should be at least twice the normal system working pressure. The 0–600 PSI range is ideal for high-pressure fire pumps operating between 150 PSI and 300 PSI.

Q: Is the Shield SD-P3 UL Listed for factory fire audits? A: Yes, the Shield SD-P3 carries UL 393 Listing specifically for fire protection systems, making it fully compliant for RMG factory and commercial building inspections.

Q: Can this gauge be used on air lines for dry-pipe sprinkler systems? A: Yes, the Shield SD-P3 is rated for both water and air pressure monitoring in wet, dry, pre-action, and deluge sprinkler systems.

Q: Does it come with an isolation valve or gauge cock? A: The Shield SD-P3 is supplied as the pressure gauge unit; 1/4″ UL-listed brass gauge cocks and snubbers are available separately at Loop Shop.

Q: What is the country of origin for Shield SD-P3?A: Shield fire protection products are engineered and sourced under Shield UK specifications.

Reviews

There are no reviews yet.

Be the first to review “Shield Pressure Gauge 0–600 psi SD-P3 — UL”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581