      • Automatic Air Bleeding: Continuously vents trapped air pockets from pressurized fire sprinkler risers, wet-pipe networks, and hydrant mains without manual intervention.

      • Verified Engineering Specs: 25 mm (1″ DN25) threaded connection (NPT/BSPT/BSPP), 200 PSI (13.8 Bar / 1380 kPa) maximum working pressure, and compact 125 mm × 137 mm footprint.

      • Heavy-Duty Materials: Constructed with an ASTM A536 65-45-12 ductile iron body and cover, AISI 304 stainless steel float and trim, and a commercial Viton orifice button.

      • Compliance & Reliability: FM Approved (Class 1344) to eliminate air-lock surge, false waterflow alarms, and internal pipe corrosion in Bangladesh’s industrial RMG factories, commercial high-rises, and NFPA-compliant fire pump rooms

Best Price Guaranteed

Description

Product Overview

  • What is this product? The GALA Fig. 9712 is a 25 mm (1-inch / DN25) FM Approved Automatic Air Release Valve engineered specifically for pressurized fire protection water piping systems.

  • How does it work? Installed at system high points, the valve utilizes an internal AISI 304 stainless steel float connected to a lever mechanism and Viton orifice seal. When air accumulates in the valve chamber, the water level drops, causing the float to descend and open the 1.6 mm orifice to exhaust trapped air. Once air is purged and water rises back into the body, buoyancy lifts the float to seal the orifice drip-tight against line pressure up to 200 PSI.

  • Who needs this product? MEP contractors, fire safety engineers, industrial plant managers, and building owners designing or maintaining wet-pipe sprinkler networks, standpipes, and fire hydrant systems.

  • Why is it useful in Bangladesh? Ready-Made Garment (RMG) factories, textile mills, pharmaceutical plants, and commercial towers in Bangladesh require strict adherence to NFPA 13, BNBC, and international buyer safety audits (such as RSC/Accord standards). Entrapped air in wet sprinkler grids triggers false alarm-valve trips, accelerates oxygen-induced pipe corrosion, and causes destructive hydraulic surges during fire pump startups.

Key Features

  • FM Approved Performance: Certified under FM Approvals Class 1344 (Approval IDs: PR452028 / 0003059096) for fire protection air release applications.

  • Corrosion-Resistant Internal Trim: Float, float arm, lever, and seat ring are fabricated from AISI 304 stainless steel for continuous immersion durability.

  • High-Strength Ductile Iron Housing: Body and bolted cover manufactured from ASTM A536 Grade 65-45-12 ductile iron with protective red fusion-bonded epoxy coating.

  • Positive Bubble-Tight Sealing: Precision 1.6 mm discharge orifice paired with a resilient commercial Viton orifice button prevents water weeping under static system pressure.

  • Universal Threaded Interface: Available with standard 1″ (25 mm) NPT, BSPT, or BSPP female threaded connections for seamless integration into local piping headers.

Technical Advantages

  • Surge & Water Hammer Prevention: Eliminates compressible air pockets at elevated piping loops, preventing pressure spikes and mechanical shock when main electric or diesel fire pumps engage.

  • Accelerated Corrosion Control: Purging dissolved and pocketed oxygen from wet sprinkler mains significantly reduces microbiologically influenced corrosion (MIC) and internal rust buildup.

  • Accurate Alarm Integrity: Prevents air compression fluctuations from falsely tripping wet alarm check valves or vane-type waterflow detectors.

  • Service-Friendly Top-Entry Design: Bolted ductile iron cover permits direct inspection or cleaning of the stainless steel float assembly and Viton button without unthreading the valve body from the riser.

Applications

  • Industrial & Factory: Wet-pipe sprinkler systems and ring mains in RMG factories, spinning mills, and economic zones (BEPZA / BEZA).

  • Commercial & Office: High-rise office towers, shopping malls, hotels, and corporate headquarters requiring BNBC and NFPA-compliant fire networks.

  • Project Installation: Fire pump room discharge headers, standpipe riser tops, and high-elevation piping crossovers in hospitals, warehouses, and institutional complexes.

Why Choose This Product?

  • Audit-Ready Certification: Carrying recognized FM Approval ensures smooth inspection sign-offs by Bangladesh Fire Service and Civil Defence (FSCD) and international compliance auditors.

  • Rugged Industrial Longevity: Unlike lightweight brass domestic air vents, the ductile iron body and full SS304 internal mechanism withstand high-pressure fire main transients for decades.

  • Cost-Effective Asset Protection: Protects expensive alarm check valves, pressure gauges, and steel sprinkler piping from premature failure and false-alarm downtime.

4. Technical Specification Table

Specification Details
Model Fig. 9712
Brand GALA (Gala RS Inc.)
Nominal Size 25 mm (1″ / DN25)
Maximum Working Pressure 200 PSI (13.8 Bar / 1380 kPa)
Connection Standard Threaded — NPT / BSPT / BSPP (1″ Inlet)
Orifice Diameter 1.6 mm
Body & Cover Material Ductile Iron (ASTM A536 Grade 65-45-12), Red Fusion Bonded
Internal Trim Material Float, Lever, Float Arm & Seat Ring: Stainless Steel AISI 304
Orifice Button Material Viton (Commercial Grade)
Approval & Listing FM Approved (Class 1344)
Dimension Diameter (D): 125 mm × Height (H): 137 mm
Medium Clean Water / Fire Protection Sprinkler Water

(Note: Applicable mechanical, dimensional, and material specifications for this non-electrical hydraulic valve are listed above per official GALA Fig. 9712 technical documentation.)

5. Features List

  • ✓ FM Approved (Class 1344) for fire protection systems

  • ✓ Heavy-duty ASTM A536 65-45-12 ductile iron body and cover

  • ✓ Full AISI 304 stainless steel float, lever, and seat ring

  • ✓ Viton orifice button for drip-tight sealing up to 200 PSI

  • ✓ Compact 125 mm × 137 mm footprint for tight ceiling voids

  • ✓ Top-access bolted cover for simplified maintenance

6. Benefits For Customers

  • Prevents False Sprinkler Alarms: Removes trapped air pockets that cause pressure surges and nuisance waterflow switch activations.

  • Extends Piping Service Life: Expels oxygen-rich air from wet-pipe networks, minimizing internal rust and pinhole leaks in Bangladesh’s humid climate.

  • Protects Fire Pumps & Gauges: Cushions hydraulic shock and prevents erratic pressure gauge oscillations during jockey and main pump cycling.

  • Ensures Regulatory Compliance: Meets strict FM Approved component mandates for industrial fire safety audits in Bangladesh.

7. Installation & Maintenance Guide

  • Installation Requirements:

    • Mount strictly in a vertical upright position at the highest elevation points of the fire sprinkler grid, riser top, or pump discharge header where air naturally collects.

    • Install a 1″ (25 mm) UL/FM listed isolation ball valve immediately upstream of the air release valve to allow servicing without draining the entire fire main.

    • Apply approved PTFE thread sealant tape or pipe dope to the 1″ male thread before threading into the valve inlet; do not over-torque.

    • Pipe the top exhaust outlet (1/2″ / 15 mm) to a visible floor drain or safe discharge point to prevent water damage during purging.

  • Maintenance Tips:

    • Inspect the exhaust port quarterly during routine fire system walkthroughs to confirm there is no continuous water weeping.

    • Flush the valve chamber annually by closing the upstream isolation valve, unbolting the top cover, and rinsing any pipe scale or sediment off the SS304 float and Viton orifice button.

  • Safety Instructions:

    • Never unbolt the cover or remove the valve while the fire protection main is pressurized.

    • Close the upstream isolation valve and verify zero residual pressure before performing any inspection or cleaning.

8. FAQ Section

Q: What is the price of GALA 25 mm (1″) Automatic Air Release Valve in Bangladesh? A: The price of the GALA Fig. 9712 25 mm (1″) FM Approved Automatic Air Release Valve in Bangladesh varies depending on order volume (single unit vs. project BOQ bulk quantity) and current import duties. Contact Loop Shop BD directly for the latest BDT quotation.

Q: Where can I buy GALA Automatic Air Release Valve in Bangladesh? A: You can order the genuine GALA Fig. 9712 25 mm (1″) Air Release Valve online directly from loopshop.com.bd with nationwide delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial zones in Bangladesh.

Q: Is this GALA Air Release Valve UL Listed or FM Approved? A: The GALA Fig. 9712 Automatic Air Release Valve (sizes 1/2″, 3/4″, and 1″) is officially FM Approved under FM Approvals Class 1344 for fire protection systems. (Note: In fire protection piping specifications, GALA Fig. 9712 carries FM Approval specifically).

Q: What warranty does this product have? A: It is covered by the standard manufacturer’s warranty against manufacturing and material defects. Contact our technical sales team at loopshop.com.bd for project-specific warranty terms and certificate documentation.

Q: Is this valve suitable for Bangladesh’s climate and industrial environment? A: Yes. Its fusion-bonded epoxy-coated ductile iron housing and AISI 304 stainless steel internal components resist high ambient humidity, heat, and industrial plant environments across Bangladesh.

Q: How do I install this 25 mm automatic air release valve? A: Install the valve vertically upright at the highest point of the water pipeline using a 1″ threaded connection, paired with an upstream isolation ball valve for future maintenance and a drain line from the top vent port.

Q: What is the maximum working pressure of the GALA Fig. 9712 valve? A: The GALA Fig. 9712 is rated for a maximum working pressure of 200 PSI (13.8 Bar / 1380 kPa).

Q: Can this valve be used on wet-pipe fire sprinkler systems? A: Yes, it is specifically designed for wet-pipe fire sprinkler systems, standpipes, and hydrant networks to automatically vent trapped air as required by NFPA 13 guidelines.

Q: What thread standards are supported for the 25 mm inlet? A: The 1″ (25 mm) inlet connection is available in standard NPT, BSPT, or BSPP female threads to match standard steel fire piping fittings in Bangladesh.

Q: Why is an isolation ball valve recommended below the air vent? A: Installing a 1″ isolation ball valve directly beneath the air release valve allows technicians to isolate, clean, or replace the air vent without shutting down or draining the entire building’s fire sprinkler zone.

Reviews

There are no reviews yet.

Be the first to review “GALA 9712 Automatic Air Release Valve 25mm 1″ FM Approved Fire System”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581