Description
Product Overview
What is this product? The UL Listed Compound Pressure Gauge (available in genuine Winters Instruments and WIKA models) is a specialized dual-range Bourdon tube pressure and vacuum gauge engineered specifically for fire pump suction lines.
How does it work? Unlike standard pressure gauges that only read positive pressure above atmospheric levels, a compound gauge measures both positive static head pressure (in PSI / bar) and negative suction pressure or vacuum (in inches of mercury – inHg) on a single easy-to-read dial. When a fire pump draws water from an underground reservoir or suction tank, the internal phosphor bronze / copper alloy Bourdon tube flexes accurately in either direction to display real-time suction conditions.
Who needs this product? Fire protection contractors, MEP engineers, factory maintenance managers, and fire safety consultants installing or upgrading electric and diesel centrifugal fire pump systems.
Why is it useful in Bangladesh? Under NFPA 20 and Bangladesh National Building Code (BNBC) fire safety standards, every centrifugal fire pump must be fitted with a UL Listed compound pressure/vacuum gauge on the suction pipe. In industrial hubs across Dhaka, Gazipur, Chattogram, and Narayanganj—where pumps frequently draw from underground water tanks—monitoring suction vacuum is essential to prevent pump cavitation and pass RSC/Accord-aligned factory fire audits.
Key Features
-
UL Listed & FM Approved: Certified under UL-393 specifically for fire protection and sprinkler pump service.
-
Genuine Winters / WIKA Quality: Manufactured by world-renowned instrumentation leaders known for long-term calibration stability.
-
Dual Pressure & Vacuum Scale: Clearly displays positive pressure (PSI / bar) and vacuum (-30 inHg to 0) on a high-contrast white aluminum dial.
-
Standard 1/4″ NPT Lower Mount: Fits standard fire pump suction gauge cocks and snubber assemblies effortlessly.
-
Corrosion-Resistant Wetted Parts: Equipped with a brass/copper alloy socket and Bourdon tube engineered for continuous water service.
-
Over-Travel Stop Pin & Shatter-Resistant Lens: Protects internal gear movement against sudden suction surges and mechanical impact in busy pump rooms.
Technical Advantages
-
Early Cavitation & Blockage Detection: Instantly alerts operators if suction strainers, foot valves, or intake lines become obstructed.
-
Vibration & Surge Resilience: Precision brass movement and rugged housing withstand continuous pump room vibration and pressure spikes.
-
High-Visibility Dial Readout: Large 3.5″ (90 mm) or 4″ (100 mm) dial with bold black and red markings allows quick visual checks during weekly fire pump testing.
-
ASME B40.100 Compliant Accuracy: Delivers dependable Grade B (±3-2-3% of span) measurement accuracy across the operating range.
Applications
-
Fire Pump Suction Piping: Mandatory suction-side monitoring for horizontal split-case and end-suction centrifugal fire pumps.
-
RMG & Textile Factory Pump Rooms: Compliance instrumentation for garment factories, spinning mills, and dyeing plants.
-
Commercial & High-Rise Buildings: Fire hydrant and automatic sprinkler pump skids in shopping malls, hotels, and corporate towers.
-
Underground Reservoir Pumping Systems: Monitoring negative suction lift and positive flooded-suction head pressure.
Why Choose This Product?
-
Audit-Ready Certification: Genuine UL Listed markings eliminate compliance rejections during factory and commercial building fire inspections.
-
Trusted Global Brands: Supplied in authentic Winters Instruments or WIKA models depending on project specification and stock availability.
-
Prevents Costly Pump Damage: Helps maintenance teams catch suction starvation before cavitation destroys pump impellers and mechanical seals.
-
Reliable Local Supply: Sourced and supported in Bangladesh by Loop Engineering & Loop Shop with fast nationwide delivery.
4. Technical Specification Table
| Specification | Details |
| Product Name | UL Listed Compound Pressure & Vacuum Gauge |
| Available Brands | Winters Instruments / WIKA |
| Certification | UL Listed (UL-393) & FM Approved |
| Standard Compliance | ASME B40.100 (Grade B) / EN 837-1 |
| Dial Size | 3.5″ (90 mm) / 4″ (100 mm) |
| Measurement Type | Compound (Vacuum & Positive Pressure) |
| Pressure & Vacuum Range | -30 inHg to 0 to 150 / 300 PSI (Dual Scale PSI / bar / kPa) |
| Process Connection | 1/4″ NPT Lower Mount (Bottom Connection) |
| Wetted Parts (Tube & Socket) | Brass / Copper Alloy (Phosphor Bronze Bourdon Tube) |
| Case & Window Material | Corrosion-Resistant Steel / Polycarbonate Case with Clear Lens |
| Accuracy Class | ±3-2-3% of Span (ASME Grade B) |
| Operating Temperature | -40°C to +60°C (-40°F to +140°F) |
| Application | Centrifugal Fire Pump Suction Line |
5. Features List
-
✓ UL Listed (UL-393) & FM Approved for fire protection systems
-
✓ Authentic Winters Instruments or WIKA industrial build quality
-
✓ Measures both vacuum (-30 inHg) and positive pressure on one dial
-
✓ 1/4″ NPT standard bottom connection for quick installation
-
✓ Corrosion-resistant brass/copper alloy Bourdon tube and socket
-
✓ High-contrast 3.5″ / 4″ white dial with shatter-resistant polycarbonate window
-
✓ Built-in pointer stop pin to protect against pressure spikes
6. Benefits For Customers
-
Protects Fire Pumps from Cavitation: Provides immediate visual warning of vacuum spikes caused by blocked suction strainers or low reservoir water levels.
-
Passes Fire Safety Inspections: Meets NFPA 20, BNBC, and industrial safety audit mandates requiring UL Listed suction compound gauges.
-
Clear & Easy Monitoring: Dual-scale markings make routine weekly pump churn tests fast and error-free for facility technicians.
-
Built for Bangladesh Pump Rooms: Resistant to high ambient humidity, dust, and continuous mechanical vibration in industrial facilities.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install the compound gauge on the suction pipe near the fire pump suction flange using a 1/4″ NPT gauge cock (shutoff valve) and pressure snubber per NFPA 20 guidelines.
-
Always use a wrench on the square brass wrench flats above the threads—never twist the gauge case by hand during tightening.
-
Apply PTFE thread sealant tape carefully to the male 1/4″ NPT threads without blocking the pressure orifice.
Maintenance Tips:
-
Keep the gauge cock closed during normal standby operation and open it only when taking readings during weekly fire pump inspections to extend gauge life.
-
Check the pointer zero-return periodically; if the pointer sticks or fails to return to zero when vented, replace the gauge.
-
Keep the clear lens clean and unobstructed for rapid emergency reading.
Safety Instructions:
-
Close the gauge cock and relieve trapped line pressure before removing or replacing the gauge.
-
Do not exceed 75% of the full-scale positive pressure rating under steady operating conditions.
8. FAQ Section
Q: What is the price of UL Listed Compound Gauge (Winters / WIKA) in Bangladesh? A: The price of a genuine UL Listed Compound Pressure Gauge from Winters or WIKA in Bangladesh depends on the brand, dial size, and order quantity. Contact loopshop.com.bd directly for an exact BDT quotation.
Q: Where can I buy UL Listed Compound Gauge (Winters / WIKA) in Bangladesh? A: You can order authentic UL Listed Winters and WIKA fire pump gauges online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.
Q: What warranty does this product have? A: Genuine Winters and WIKA UL Listed gauges include a standard manufacturer defect warranty supported by Loop Shop. Contact our team for detailed project warranty terms.
Q: Is this suitable for the Bangladesh climate? A: Yes. Built with corrosion-resistant cases and brass/copper alloy internals, these gauges operate reliably in high-humidity, high-temperature fire pump rooms across Bangladesh.
Q: How to install this product? A: Thread the 1/4″ NPT bottom connection onto a dedicated gauge cock on the fire pump suction line using a wrench on the brass hex flats, ensuring the dial faces forward for clear visibility.
Q: Why is a compound gauge needed instead of a regular pressure gauge on a fire pump? A: A fire pump suction line can experience both positive pressure (from an overhead or pressurized supply) and negative vacuum (when drawing water up from an underground tank). A compound gauge measures both accurately.
Q: What is the difference between the Winters and WIKA models? A: Both Winters Instruments and WIKA are globally recognized Tier-1 instrumentation manufacturers offering UL-393 Listed, FM Approved, ASME Grade B compliant compound gauges with identical mounting and performance standards.
Q: Does this gauge comply with NFPA 20 requirements? A: Yes. NFPA 20 requires a UL Listed compound pressure/vacuum gauge connected near the suction flange of every centrifugal fire pump.
Q: Should the gauge valve stay open all the time? A: Per standard fire protection practice, the gauge cock should remain closed during standby to protect the Bourdon tube from constant vibration and be opened during weekly testing.
Q: Do you also supply the discharge pressure gauge for fire pumps? A: Yes, loopshop.com.bd supplies both UL Listed suction compound gauges and UL Listed discharge pressure gauges (0–300 PSI / 0–600 PSI) for complete fire pump installations.

Reviews
There are no reviews yet.