System Sensor WFD60 6″ (150 mm) UL/FM Water Flow Switch for Sprinklers

                                                              • Primary Purpose: Detects sustained water movement in wet-pipe fire sprinkler systems and triggers an immediate electrical signal to the fire alarm control panel.

                                                              • Key Specifications: Model WFD60 for 6-inch (150 mm) Schedule 10–40 steel pipes, UL Listed and FM Approved, dual SPDT snap-action switches, and an adjustable mechanical retard (0–90 seconds).

                                                              • Customer Benefits: Eliminates false alarms caused by water pressure surges while ensuring rapid, code-compliant sprinkler activation monitoring.

                                                              • Bangladesh Market Relevance: Essential for RMG textile factories, commercial high-rises, pharmaceutical plants, and industrial warehouses across Bangladesh requiring NFPA 13, BNBC, and international fire audit compliance.

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-2-1-1 Category Tags: , , , ,

Description

Product Overview

What is this product? The System Sensor WFD60 is a vane-type electromechanical water flow detector designed specifically for 6-inch (150 mm) wet-pipe fire sprinkler risers and branch lines.

How does it work? A flexible polyethylene paddle (vane) extends into the sprinkler pipe through a drilled hole and is secured via a U-bolt saddle assembly. When one or more sprinkler heads open during a fire, water flows through the pipe and deflects the vane. This movement activates a pneumatic retard mechanism that delays switching for an adjustable period (up to 90 seconds) to ignore brief pressure spikes, before tripping two synchronized SPDT micro-switches to alert the Fire Alarm Control Panel (FACP) and local alarm bells.

Who needs this product? Fire protection contractors, MEP engineers, factory compliance teams, and facility managers designing, installing, or upgrading wet sprinkler systems in commercial and industrial buildings.

Why is it useful in Bangladesh? Export-oriented garment factories, industrial complexes, and commercial buildings in Dhaka, Gazipur, Chattogram, and Narayanganj face strict fire safety inspections under BNBC, NFPA 13, and global buyer audit protocols. The System Sensor WFD60 delivers UL/FM-certified flow detection with rugged NEMA 4 environmental protection, preventing nuisance false alarms caused by municipal water pressure fluctuations or pump cycling.

Key Features

  • UL Listed & FM Approved: Certified to rigorous international fire protection standards for wet-pipe sprinkler systems.

  • 6-Inch (150 mm) Pipe Compatibility: Engineered for Schedule 10 through Schedule 40 steel fire sprinkler pipes.

  • Adjustable Pneumatic Retard (0–90 Seconds): Prevents false alarms triggered by transient water surges or pressure fluctuations.

  • Dual SPDT Snap-Action Switches: Two synchronized Form-C contacts allow simultaneous signaling to both the main fire alarm panel and local notification appliances.

  • NEMA 4 Weatherproof Enclosure: Sealed housing protects internal components against dust, moisture, and splash exposure in pump rooms and risers.

  • Tamper-Resistant Cover: Equipped with specialized security screws to prevent unauthorized access or accidental tampering.

  • Visual Switch Activation Indicator: Clear mechanical indication simplifies testing, commissioning, and routine maintenance inspections.

Technical Advantages

  • False-Alarm Immunity: Precision mechanical pneumatic retard isolates true fire flow from brief hydraulic hammer or booster pump start-up surges.

  • Corrosion-Resistant Wetted Parts: Non-corrosive flexible paddle and durable stem construction resist scaling and mineral buildup inside stagnant sprinkler mains.

  • Simple Wiring & Commissioning: Generous conduit knockouts, clear terminal blocks, and an intuitive retard dial speed up field installation.

  • Long Service Reliability: Rugged die-cast metal base and sealed housing withstand demanding industrial operating conditions with minimal upkeep.

Applications

  • Industrial & RMG Factories: Main sprinkler risers and zone control assemblies in textile mills, garments, and logistics warehouses.

  • Commercial Buildings: High-rise office towers, shopping malls, hotels, and convention centers.

  • Institutional & Healthcare: Hospitals, universities, and government complexes with zoned wet-pipe sprinkler networks.

  • Project Installations: New NFPA 13 sprinkler installations, fire alarm integration projects, and factory compliance retrofits.

Why Choose This Product?

  • Global Industry Benchmark: System Sensor (by Honeywell) is the most widely specified and trusted brand for sprinkler supervisory and flow devices worldwide.

  • Audit-Ready Certification: Genuine UL/FM approvals ensure smooth sign-off from fire safety consultants, insurers, and regulatory authorities in Bangladesh.

  • Reduced Operational Disruptions: Built-in surge delay eliminates costly false evacuations and nuisance fire alarm troubles.

  • Local Engineering Support: Supplied in Bangladesh by loopshop.com.bd with technical verification, compatibility guidance, and nationwide delivery.

4. Technical Specification Table

Specification Details
Model WFD60
Brand System Sensor
Product Type Vane-Type Water Flow Detector
Pipe Size 6 Inch (150 mm) Schedule 10–40 Steel Pipe
Certifications UL Listed, FM Approved
Switch Contact Rating Dual SPDT (Form C), 10 A @ 125/250 VAC; 2.5 A @ 24 VDC
Retard Adjustment 0 to 90 Seconds (Pneumatic Mechanical)
Enclosure Rating NEMA 4 (Indoor/Outdoor Dust & Splash Resistant)
Conduit Entrances Two 1/2″ Conduit Openings
Operating Temperature 32°F to 120°F (0°C to 49°C)
Service Pressure Up to 450 PSI (31 bar)
Flow Sensitivity 4 to 10 GPM (15 to 38 LPM)

5. Features List

  • ✓ UL Listed and FM Approved for wet-pipe sprinkler systems

  • ✓ Sized specifically for 6-inch (150 mm) Schedule 10–40 steel pipes

  • ✓ Adjustable 0–90 second mechanical retard prevents false alarms

  • ✓ Dual SPDT (Form C) switches for fire alarm panel and local bell signaling

  • ✓ Weather-resistant NEMA 4 enclosure with tamper-resistant cover screws

  • ✓ Rated up to 450 PSI static working pressure

  • ✓ Easy-to-wire terminal block with dual 1/2″ conduit knockouts

6. Benefits For Customers

  • Eliminates Nuisance False Alarms: Adjustable retard timer filters out momentary pressure surges from jockey pumps or city main fluctuations.

  • Ensures Rapid Fire Response: Accurately pinpoints the active sprinkler zone on the Fire Alarm Control Panel within seconds of sprinkler discharge.

  • Passes Strict Fire Audits: Meets NFPA 13, BNBC, and international buyer compliance requirements in Bangladesh.

  • Durable in Humid Environments: NEMA 4 sealed housing and corrosion-resistant paddle ensure reliable performance in damp pump rooms and industrial risers.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount on a straight horizontal or vertical section of 6″ (150 mm) Schedule 10–40 steel pipe at least 6 inches (150 mm) away from any fitting that changes water direction, and at least 24 inches (600 mm) away from any valve or drain.

  • Drill a clean, burr-free mounting hole matching the manufacturer template, insert the flexible vane carefully without bending it, and tighten the U-bolt nuts evenly.

  • Ensure the directional flow arrow on the casting matches the actual direction of water flow.

Maintenance Tips:

  • Test water flow activation quarterly by opening the inspector’s test valve at the end of the sprinkler branch line and verifying alarm timing at the FACP.

  • Inspect the enclosure gasket and tamper screws during semi-annual fire alarm maintenance to maintain NEMA 4 sealing.

  • Check that the retard dial remains set to the engineered delay time (typically 30–60 seconds).

Safety Instructions:

  • Drain and depressurize the sprinkler zone completely before drilling the pipe or installing/removing the water flow switch.

  • Disconnect alarm circuits before wiring or servicing internal terminals to avoid electrical shock or unintended fire department dispatch.

8. FAQ Section

Q: What is the price of System Sensor WFD60 Water Flow Switch in Bangladesh? A: The price of the System Sensor WFD60 6″ (150 mm) Water Flow Switch in Bangladesh depends on current import costs and order volume. Visit loopshop.com.bd or contact our sales team for an instant BDT quote and project pricing.

Q: Where can I buy System Sensor WFD60 Water Flow Switch in Bangladesh? A: You can order genuine System Sensor WFD60 water flow detectors directly from loopshop.com.bd with fast delivery to Dhaka, Gazipur, Chattogram, Narayanganj, Savar, and across Bangladesh.

Q: What warranty does this product have? A: The System Sensor WFD60 includes a manufacturer defect warranty backed by Loop Shop Bangladesh. Contact our support team with your invoice or project reference for full warranty coverage details.

Q: Is this suitable for the Bangladesh climate? A: Yes. With a NEMA 4 sealed enclosure and an operating temperature range of 0°C to 49°C (32°F to 120°F), it is well suited for humid pump rooms and industrial buildings in Bangladesh.

Q: How to install this product? A: Isolate and drain the 6″ sprinkler pipe, drill the specified hole away from valves and elbows, insert the paddle aligned with the flow arrow, secure the U-bolt, and wire the SPDT contacts to your fire alarm monitor module.

Q: Can the System Sensor WFD60 be used on dry-pipe sprinkler systems? A: No. The WFD60 is designed exclusively for wet-pipe fire sprinkler systems where pipes remain filled with pressurized water.

Q: What pipe schedules does the WFD60 fit? A: It fits standard 6-inch (150 mm) Schedule 10 through Schedule 40 steel fire sprinkler pipes.

Q: Why does the WFD60 have two SPDT switches? A: Having two independent Form-C (SPDT) switches allows one circuit to report to the addressable Fire Alarm Control Panel (FACP) while the second circuit activates a local bell, strobe, or pump room annunciator.

Q: How does the retard mechanism work? A: It uses a sealed pneumatic timing mechanism adjustable from 0 to 90 seconds so brief water surges do not trigger false alarms, while continuous sprinkler flow trips the switches reliably.

Q: Is this model UL Listed and FM Approved? A: Yes, the System Sensor WFD60 carries both UL Listing and FM Approval, satisfying international and local Bangladesh fire safety audit standards.

Reviews

There are no reviews yet.

Be the first to review “System Sensor WFD60 6″ (150 mm) UL/FM Water Flow Switch for Sprinklers”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581