  • Core Purpose: Compact interface module with an integrated S7-300 central processing unit (CPU) designed for decentralized control and standalone processing within SIMATIC ET 200S distributed I/O systems.
  • Key Specifications: Integrated PROFINET interface (3x RJ45 ports with 2-port switch), optional PROFIBUS DP interface (via master module), 192 KB work memory, and 24V DC power supply.
  • Customer Benefits: Combines PLC control and distributed I/O in a single footprint, reduces main panel wiring costs, speeds up fieldbus response times, and supports seamless PROFINET industrial networking.
  • Bangladesh Market Relevance: Essential for upgrading, repairing, and automating production lines in Bangladesh’s textile spinning, garment processing, pharmaceutical, and packaging plants using ET 200S architecture.
Best Price Guaranteed

Description

The Siemens SIMATIC DP IM151-8 PN/DP CPU for ET 200S (Part Number: 6ES7151-8AB01-0AB0) is a high-performance interface module with integrated CPU functionality based on the S7-300 CPU 314 processing engine. Designed specifically for the modular SIMATIC ET 200S system, it functions both as an intelligent head station for local distributed I/O and as a standalone field controller capable of executing complex automation programs.

Equipped with 192 KB work memory and a built-in PROFINET interface with three RJ45 sockets (including a 2-port switch for line topologies), this module processes fast logic, arithmetic, and motion control functions. For automation engineers, machine builders, and maintenance teams in Bangladesh, the 6ES7151-8AB01-0AB0 provides an efficient, space-saving control head to decentralize processing and reduce central PLC workloads.

Key Features

  • Integrated S7-300 Processing Core: High-speed execution of control programs with 192 KB integrated work memory (requires SIMATIC Micro Memory Card).
  • Onboard PROFINET Communication: Features 3x RJ45 PROFINET ports with an integrated 2-port switch for flexible line and ring network topologies.
  • ET 200S Modular Expansion: Directly drives and manages up to 63 local ET 200S I/O modules on the same station backplane.
  • Flexible Fieldbus Support: Supports PROFINET IO controller, IO device, and open IE communication; expandable to PROFIBUS DP Master using optional PROFIBUS master module.
  • Real-Time Clock & Diagnostics: Onboard real-time clock, hardware diagnostics, and comprehensive LED status monitoring for system and network health.

Technical Advantages

  • High Efficiency: Offloads processing tasks from central controllers by performing real-time control at the field level.
  • Durable Construction: Rugged IP20 housing engineered to withstand harsh industrial panel environments, vibration, and electrical noise.
  • Safety & Data Security: Supports password-protected program access and integrated firmware protection against unauthorized changes.
  • Energy Saving: Optimized internal electronics reduce module power loss and heat generation inside closed electrical cabinets.
  • Easy Maintenance: Web server capabilities and diagnostic LEDs enable quick maintenance and remote fault localization without specialized tools.

Applications

  • Industrial: Automated conveyor networks, material handling systems, pump control stations, and packaging machines.
  • Factory: Textile spinning and dyeing control units, pharmaceutical processing, garment washing machines, and food production lines.
  • Commercial: Centralized HVAC control panels, automated building management systems, and water treatment skids.
  • Project Installation: Control panel modernization, distributed machine automation, and industrial Ethernet network integration across Bangladesh.

Why Choose This Product?

  • 2-in-1 Integration: Combines interface head and PLC controller into one module, drastically cutting DIN rail footprint and cabinet hardware costs.
  • High Communication Versatility: Triple-port PROFINET interface allows easy daisy-chaining without requiring external industrial Ethernet switches.
  • Proven Performance in BD: Widely deployed across Bangladesh’s industrial zones for its rock-solid reliability in high-duty production environments.
  • Dedicated Local Supply: Sourced directly through loopshop.com.bd with verified technical support and fast nationwide delivery.

Technical Specification Table

Specification Details
Model IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0)
Brand Siemens
Rated Power Power loss typ. 5.5 W
Voltage 24 V DC (Permissible range: 20.4 V to 28.8 V DC)
Current Current consumption typ. 320 mA; max. 420 mA
Frequency Not Applicable (DC Module)
Efficiency Not Available
Protection IP20
Dimension 120 mm x 119.5 mm x 75 mm (W x H x D)
Weight Approx. 320 g
Operating Temperature 0 °C to +60 °C (Horizontal installation)
Warranty Standard Manufacturer Warranty

 

 


Features List

✓ Integrated S7-300 CPU engine with 192 KB work memory

✓ Built-in PROFINET interface with 3x RJ45 ports (integrated 2-port switch)

✓ Directly manages up to 63 ET 200S I/O modules on local station

✓ Supports PROFINET IO Controller and IO Device modes

✓ Expansion option for PROFIBUS DP Master functionality

✓ Integrated web server and hardware diagnostics support

Benefits For Customers

  • Reduces System Costs: Eliminates the need for a separate central CPU by executing logic directly on the ET 200S station.
  • Improves Operational Reliability: Local processing ensures field loops continue operating with low latency regardless of main network traffic.
  • Saves Cabling & Switch Costs: Built-in 2-port PROFINET switch allows direct daisy-chain wiring between panels without extra switches.
  • Suitable for Bangladesh Environment: Performs reliably in panel ambient temperatures up to +60 °C across factories in Bangladesh.

Installation & Maintenance Guide

Installation Requirements:

  1. Mount the ET 200S standard DIN rail horizontally inside an IP54-rated or clean control panel enclosure.
  2. Snap the IM151-8 PN/DP CPU onto the rail on the left side of the ET 200S station rack.
  3. Insert a valid SIMATIC Micro Memory Card (MMC) into the CPU slot (required for operation and memory retention).
  4. Connect the 24V DC power supply cables to the front terminal connections, observing correct polarity.
  5. Plug industrial Ethernet cables into the RJ45 PROFINET ports.

Maintenance Tips:

  1. Routinely check the front LED displays (SF, BF, MT, ON, RUN, STOP) to verify CPU and communication status.
  2. Ensure panel ventilation fans and air filters are cleaned regularly to prevent dust buildup on heatsinks and ports.
  3. Back up program files and hardware configuration data in STEP 7 or TIA Portal before executing field maintenance.

Safety Instructions:

  1. Installation and wiring must be performed by qualified automation technicians or electrical engineers.
  2. Ensure power to the station is switched off before inserting or removing the SIMATIC Micro Memory Card.
  3. Observe recommended wire gauges and fuse protection on the 24V DC main feed line.

Frequently Asked Questions (FAQ)

Q: What is the price of Siemens IM151-8 PN/DP CPU 6ES7151-8AB01-0AB0 in Bangladesh?

A: Prices depend on import rates, duty, and stock availability. Contact loopshop.com.bd or visit our online store for an accurate price quote in BDT.

Q: Where can I buy Siemens IM151-8 PN/DP CPU 6ES7151-8AB01-0AB0 in Bangladesh?

A: You can purchase directly online from loopshop.com.bd with express shipping across Dhaka, Chattogram, Gazipur, Narayanganj, and island-wide industrial districts.

Q: What warranty does this product have?

A: loopshop.com.bd offers standard vendor/seller warranty against manufacturing defects upon purchase.

Q: Is this suitable for Bangladesh climate?

A: Yes, it is engineered for industrial environments and operates in ambient temperatures from 0 °C to +60 °C inside ventilated control cabinets.

Q: How to install this product?

A: Mount on an ET 200S DIN rail, insert a SIMATIC MMC card, wire 24V DC power, connect PROFINET cables, and download your program using STEP 7 or TIA Portal.

Q: Does this module require a memory card to operate?

A: Yes, a SIMATIC Micro Memory Card (MMC) is mandatory for program storage and operation of the IM151-8 CPU.

Q: How many RJ45 PROFINET ports are integrated into 6ES7151-8AB01-0AB0?

A: It features 3x RJ45 PROFINET ports, including an integrated 2-port switch for line topology wiring.

Q: Can this CPU communicate over PROFIBUS DP?

A: Yes, it can support PROFIBUS DP Master functionality by adding an optional PROFIBUS master interface module.

Q: Which software is used to program 6ES7151-8AB01-0AB0?

A: It can be programmed using Siemens STEP 7 V5.5 or higher, or TIA Portal (SIMATIC STEP 7 Professional).

Q: Does loopshop.com.bd supply original Siemens PLCs in Bangladesh?

A: Yes, loopshop.com.bd supplies 100% original Siemens industrial automation components sourced from authorized distribution channels.

Reviews

There are no reviews yet.

Be the first to review “Siemens IM151-8 PN/DP CPU ET200S Controller 6ES7151-8AB01-0AB0 PLC”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581