Description
Product Overview
What is this product? The Shield 65 mm (2-1/2″) UL/FM Sprinkler Zone Control Valve Set (incorporating the Shield SD-TDV50T Test & Drain Valve) is a complete, floor-level fire protection control assembly designed for wet-pipe automatic fire sprinkler networks.
How does it work? Installed at the riser take-off for each floor or fire zone, the assembly combines a supervised isolation butterfly valve, a vane-type water flow detector, a system pressure gauge, and the Shield SD-TDV50T Test & Drain Valve with an integrated sight glass and calibrated test orifice. When a sprinkler activates, water movement triggers the flow switch to alert the fire alarm control panel (FACP). During routine inspections, the SD-TDV50T simulates single-sprinkler flow to test alarm response or drains the zone piping safely.
Who needs this product? Fire protection contractors, MEP engineering firms, RMG factory compliance managers, and commercial building developers implementing multi-zone automatic sprinkler systems.
Why is it useful in Bangladesh? Multi-story textile and garment factories, pharmaceutical plants, and commercial towers in Dhaka, Gazipur, Narayanganj, and Chattogram must meet strict NFPA 13 and Bangladesh National Building Code (BNBC) zoning rules. A factory-matched Shield UK UL/FM zone control valve assembly ensures zero-leakage isolation, reliable tamper/flow supervision, and smooth sign-off during third-party fire safety inspections.
Key Features
-
UL Listed & FM Approved Assembly: Every critical valve and detection component carries UL Listing and/or FM Approval for fire protection service.
-
Complete Integrated Zone Station: Combines isolation control, tamper supervision, flow alarm detection, pressure monitoring, and test/drain functions in one compact riser assembly.
-
Shield SD-TDV50T Test & Drain Valve Included: Features a 3-position single-handle forged brass ball valve (
OFF/TEST/DRAIN) with a tamper-resistant K-factor test orifice and dual-sided sight glass for clear visual flow verification. -
Supervised Butterfly Isolation Valve: Equipped with an integrated tamper switch that signals the fire alarm panel immediately if the valve is partially or fully closed.
-
High-Sensitivity Water Flow Switch: Vane-type detector with an adjustable pneumatic retard mechanism to prevent false alarms caused by water pressure surges.
-
300 PSI / 175 PSI Rated Pressure Performance: Built for high-rise and industrial sprinkler riser pressures with heavy-duty ductile iron and forged brass construction.
Technical Advantages
-
Localized Zone Isolation: Allows technicians to drain and service a single floor or production zone without disabling fire suppression across the entire facility.
-
Fast, Mess-Free NFPA 13 Testing: The integrated SD-TDV50T test orifice accurately replicates the discharge of a single sprinkler head, verifying flow switch operation in seconds without climbing ladders or flooding floors.
-
Corrosion & Scale Resistance: Epoxy-coated ductile iron main valve body paired with a forged brass test & drain assembly resists internal mineral buildup in local water networks.
-
Seamless FACP Integration: Dry-contact supervisory and water-flow switch outputs interface directly with conventional or addressable fire alarm monitor modules.
Applications
-
RMG & Textile Factories: Multi-floor sewing, cutting, finishing, and warehouse sprinkler zoning in Gazipur, Savar, Ashulia, and Narayanganj.
-
Commercial High-Rises & Malls: Floor-by-floor sprinkler riser control in office towers, hotels, and shopping complexes in Dhaka and Chattogram.
-
Hospitals & Pharmaceuticals: Cleanroom and patient-wing sprinkler zoning requiring isolated maintenance capability.
-
Industrial Warehouses & Logistics Hubs: High-piled storage sprinkler zone control and compliance upgrades.
Why Choose This Product?
-
Trusted UK Engineering Brand: Shield (United Kingdom) is widely approved by fire safety consultants and industrial auditors across Bangladesh.
-
Audit-Ready Certification: Genuine UL/FM markings eliminate compliance rejections during RSC, Nirapon, and Fire Service & Civil Defence (FSCD) inspections.
-
Matched Component Compatibility: Eliminates thread mismatches, pressure-rating discrepancies, and site fabrication delays by sourcing a unified Shield valve set.
-
Backed by Loop Shop Bangladesh: Supported by local engineering consultation, BOQ verification, and nationwide delivery through Loop Engineering & Loop Shop.
4. Technical Specification Table
| Specification | Details |
| Product Name | Sprinkler Zone Control Valve Set |
| Brand / Origin | Shield (United Kingdom) |
| Nominal Main Size | 65 mm (2-1/2 Inch) |
| Test & Drain Valve Model | Shield SD-TDV50T (3-Position: Off / Test / Drain) |
| Certifications | UL Listed / FM Approved |
| Main Isolation Valve | Grooved Butterfly Valve with Built-In Tamper Switch |
| Flow Detection | Vane-Type Water Flow Switch with Retard Timer |
| Pressure Monitoring | UL/FM Listed Fire Sprinkler Pressure Gauge (0–300 PSI) |
| Body Materials | Epoxy-Coated Ductile Iron (Main Valve) & Forged Brass (SD-TDV50T) |
| Working Pressure Rating | 175 PSI / 300 PSI (Component Rated per UL/FM) |
| Design Standard Compliance | NFPA 13 / BNBC Wet Sprinkler Systems |
5. Features List
-
✓ Complete 65 mm (2-1/2″) fire sprinkler zone control assembly
-
✓ Genuine Shield (UK) brand with UL Listed & FM Approved certification
-
✓ Includes Shield SD-TDV50T Test & Drain Valve with sight glass & test orifice
-
✓ Supervised butterfly isolation valve with integral tamper switch
-
✓ Vane-type water flow detector with adjustable surge-delay retard
-
✓ UL/FM pressure gauge for instant visual riser pressure verification
-
✓ Heavy-duty corrosion-resistant ductile iron and forged brass build
-
✓ Fully compliant with NFPA 13 and Bangladesh factory fire audit rules
6. Benefits For Customers
-
Zero Whole-Building Shutdowns: Isolate and drain a single floor or production line for sprinkler head replacement without leaving other zones unprotected.
-
Pass Fire Audits with Confidence: Factory-certified UL/FM components from Shield UK satisfy strict international buyer and local FSCD inspection protocols.
-
Instant Leak & Fire Detection: Immediate alarm signaling on water flow or unauthorized valve closure minimizes water damage and accelerates emergency response.
-
Lower Installation & Maintenance Time: Pre-matched components with an integrated sight-glass test & drain valve streamline commissioning and routine quarterly/annual testing.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install the 65 mm (2-1/2″) zone control valve assembly horizontally or vertically on the floor branch riser in accordance with the flow direction arrow on the water flow switch and butterfly valve.
-
Ensure the flow switch is mounted at least 600 mm (24 inches) downstream of any elbow, tee, or isolation valve to prevent turbulence-induced false alarms.
-
Connect the SD-TDV50T drain outlet to an adequately sized indirect drain pipe routed safely to a floor drain or exterior discharge point.
-
Wire the butterfly valve tamper switch and water flow switch supervisory circuits to the Fire Alarm Control Panel (FACP) monitor modules.
Maintenance Tips:
-
Quarterly Flow Test: Turn the SD-TDV50T handle to the
TESTposition, verify steady water flow through the sight glass, and confirm the FACP receives the flow alarm within 90 seconds. -
Supervisory Tamper Check: Slightly close the butterfly valve handwheel during routine inspections to confirm a supervisory trouble signal registers at the FACP, then return it to the full-open position.
-
Gauge & Sight Glass Inspection: Check the pressure gauge reading weekly and clean the SD-TDV50T sight glass externally so discharge flow remains clearly visible.
Safety Instructions:
-
Never leave the butterfly isolation valve closed after maintenance; verify the visual position flag and FACP status show normal open condition.
-
Ensure the drain line is unobstructed and capable of handling full-bore discharge before turning the SD-TDV50T to the
DRAINposition.
8. FAQ Section
Q: What is the price of Shield 65 mm (2-1/2″) Sprinkler Zone Control Valve Set in Bangladesh? A: The price depends on project quantity, connection configuration, and current import duties. Visit loopshop.com.bd or request a formal BDT quotation from Loop Engineering for competitive project pricing.
Q: Where can I buy Shield Sprinkler Zone Control Valve Set (SD-TDV50T) in Bangladesh? A: You can order genuine Shield UK fire sprinkler valves online through loopshop.com.bd with fast delivery to Dhaka, Gazipur, Narayanganj, Chattogram, and across Bangladesh.
Q: What warranty does this product have? A: All Shield fire protection valves supplied by Loop Shop include a manufacturer defect warranty backed by local engineering support. Contact our sales team for project warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. The epoxy-coated ductile iron and forged brass components are engineered to withstand high humidity, warm mechanical shafts, and varying water conditions in Bangladesh.
Q: How to install this product? A: Mount the 65 mm assembly at the floor sprinkler take-off using UL/FM grooved couplings, pipe the SD-TDV50T drain outlet to a dedicated drain riser, and terminate the flow and tamper switch wiring to your fire alarm panel.
Q: What components are included in a complete Sprinkler Zone Control Valve Set?A: A standard 65 mm (2-1/2″) zone control station includes a supervised grooved butterfly valve, a vane-type water flow switch, a UL/FM pressure gauge, and the Shield SD-TDV50T test & drain valve.
Q: What does the Shield SD-TDV50T valve do?A: The SD-TDV50T is a 3-position (OFF, TEST, DRAIN) test and drain valve equipped with a calibrated orifice and sight glass that simulates single-sprinkler water flow for NFPA 13 alarm testing and allows fast zone draining.
Q: Are Shield valves UL Listed and FM Approved?A: Yes, Shield UK fire sprinkler valves and zone control assemblies carry UL Listing and FM Approval, making them suitable for NFPA 13 compliant industrial and commercial installations.
Q: Why is a zone control valve set required on every floor? A: NFPA 13 and BNBC require floor-level zone control assemblies in multi-story buildings to pinpoint the exact floor where a sprinkler has activated and to allow isolated maintenance without shutting down the whole building’s sprinkler system.
Q: Can this 65 mm (2-1/2″) set be connected to a Fire Alarm Control Panel (FACP)? A: Yes. Both the butterfly valve tamper switch and the water flow detector provide volt-free dry contacts that connect directly to addressable monitor modules or conventional FACP zones