Description
Product Overview
What is this product? The Shield 100 mm (4″) UL/FM Sprinkler Zone Control Valve Set is a complete, floor-level fire sprinkler control assembly engineered in the UK to isolate, monitor, and test individual wet-pipe sprinkler zones. It integrates a 100 mm (4″) supervised isolation butterfly valve, a vane-type water flow detector switch, a pressure gauge, and the Shield SD-TDV50T-E tri-position test and drain valve.
How does it work? During normal standby operation, the supervised butterfly valve remains locked open and monitored by the fire alarm control panel (FACP). When a sprinkler head activates in that zone, water flows past the vane-type flow switch, immediately triggering a zone-specific alarm signal. For routine testing or maintenance, technicians operate the integrated SD-TDV50T-E test and drain valve—which simulates single-sprinkler discharge through a calibrated orifice with a built-in sight glass—or fully drains the zone riser without disrupting water supply to other floors.
Who needs this product? MEP contractors, fire protection engineers, RMG factory compliance teams, and facility managers installing or upgrading multi-zone automatic sprinkler systems.
Why is it useful in Bangladesh? Multi-story garments factories, spinning and dyeing facilities, hospitals, and commercial towers in Dhaka, Gazipur, Chattogram, and Narayanganj are required under NFPA 13, BNBC, and RSC/Accord safety standards to divide large sprinkler networks into manageable, supervised zones. Using a UL Listed and FM Approved Shield UK zone control valve set ensures seamless fire safety inspections and rapid zone isolation during maintenance.
Key Features
-
UL Listed & FM Approved: Certified by both Underwriters Laboratories and FM Global for commercial and industrial fire sprinkler service.
-
Integrated SD-TDV50T-E Test & Drain Valve: Features a forged brass body, chrome-plated brass ball, PTFE seats, dual tamper-resistant sight glasses, and a 3-position handle (Off, Test, Drain) rated to 300 PSI.
-
Supervised Zone Isolation: Equipped with a 100 mm (4″) gear-operated butterfly valve with built-in supervisory tamper switches that alert the fire alarm panel if closed.
-
Zone-Specific Alarm Detection: Includes a vane-type water flow switch with adjustable retard mechanism to prevent false alarms from water surges.
-
300 PSI Working Pressure Rating: Heavy-duty construction handles high-rise static heads and fire pump boost pressures safely.
-
Visual Flow & Pressure Verification: Dual sight glasses on the test/drain assembly and a clear dial pressure gauge allow instant visual confirmation during inspections.
Technical Advantages
-
Zero Whole-Building Shutdowns: Isolates single floors or production wings for sprinkler head replacement or layout changes while keeping adjacent zones active.
-
Corrosion-Resistant Internals: Forged brass test/drain valve body and coated ductile iron main valve components resist rust-binding and scale buildup over long idle periods.
-
Code-Compliant Inspector Testing: Built-in calibrated test orifice accurately simulates the flow of a single sprinkler head for hassle-free weekly and quarterly NFPA 25 testing.
-
Modular & Serviceable Design: Standardized 100 mm (4″) main connections allow straightforward alignment, replacement, or sensor servicing inside tight riser shafts.
Applications
-
RMG & Textile Factories: Floor-by-floor sprinkler zoning for sewing, cutting, finishing, and fabric storage floors.
-
Commercial High-Rises: Office towers, shopping complexes, and hotels requiring floor-level sprinkler control and alarm reporting.
-
Warehouses & Logistics Hubs: Multi-bay storage facilities needing segmented sprinkler zone control.
-
Healthcare & Institutions: Hospitals, universities, and pharmaceutical plants where uninterrupted fire protection across unaffected wings is critical.
Why Choose This Product?
-
Trusted UK Fire Engineering: Shield (UK) is widely specified by fire consultants and safety auditors across Bangladesh for water-based fire protection networks.
-
Dual International Approvals: Carries both UL Listing and FM Approval, eliminating compliance bottlenecks during third-party safety audits.
-
All-in-One Functional Control: Combines isolation, tamper supervision, flow detection, pressure monitoring, and test/drain functions in one cohesive zone station.
-
Local Engineering Support via Loop Shop: Supplied in Bangladesh by Loop Engineering & Loop Shop with technical datasheet support and project consultation.
4. Technical Specification Table
| Specification | Details |
| Brand | Shield (UK) |
| Product Type | Sprinkler Zone Control Valve Set (Wet Pipe Assembly) |
| Main Line Nominal Size | 100 mm (4 Inch) |
| Test & Drain Valve Model | Shield SD-TDV50T-E (Threaded, Tri-Position) |
| Certifications | UL Listed & FM Approved |
| Maximum Working Pressure | 300 PSI (20.7 bar) |
| Core Assembly Components | 100 mm Supervised Butterfly Valve, Water Flow Switch, Pressure Gauge, SD-TDV50T-E Test & Drain Valve |
| Test & Drain Body Material | Forged Brass (ASTM C85700) with Chrome-Plated Brass Ball & PTFE/TFM Seats |
| Test & Drain Positions | 3 Positions: Off, Test (Calibrated Orifice), Drain (Full Open) |
| Visual Inspection Feature | Built-in Tamper-Resistant Dual Sight Glasses |
| Applicable Standards | NFPA 13, NFPA 13R, NFPA 13D, NFPA 25 |
5. Features List
-
✓ UL Listed and FM Approved for automatic fire sprinkler systems
-
✓ Complete 100 mm (4″) floor-level zone control and monitoring assembly
-
✓ Includes Shield SD-TDV50T-E 3-position forged brass test and drain valve
-
✓ Built-in tamper-resistant dual sight glasses for visual flow verification
-
✓ Gear-operated isolation butterfly valve with supervisory tamper switch
-
✓ Vane-type water flow detector switch for instant FACP zone signaling
-
✓ Rated for 300 PSI maximum working pressure for high-rise and industrial use
6. Benefits For Customers
-
Simplifies Fire Safety Audits: Dual UL/FM certifications and integrated sight glasses let inspectors verify sprinkler readiness in minutes.
-
Minimizes Operational Downtime: Isolate and drain a single 100 mm (4″) zone for maintenance without taking the entire factory or building offline.
-
Prevents Accidental Valve Closure: Built-in supervisory switches immediately notify the fire alarm panel if an isolation valve is tampered with or left shut.
-
Built for Bangladesh Industrial Environments: Rugged, corrosion-resistant construction performs reliably in humid riser shafts and factory pump rooms across Bangladesh.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install the 100 mm (4″) zone control valve assembly in an accessible riser shaft or floor manifold in the exact flow direction indicated on the valve bodies and flow switch.
-
Connect the supervisory tamper switch and water flow switch terminals to supervised monitor modules on the Fire Alarm Control Panel (FACP).
-
Pipe the outlet of the SD-TDV50T-E test and drain valve to an adequately sized open drain riser capable of handling full drain flow.
Maintenance Tips:
-
Operate the SD-TDV50T-E valve to the Test position quarterly to verify water flow alarm activation at the FACP and inspect water clarity through the sight glass.
-
Check the pressure gauge weekly to confirm static zone pressure remains steady and confirm the butterfly valve indicator shows fully open.
-
Inspect the flow switch retard timer and supervisory switch contacts during scheduled semi-annual fire alarm maintenance.
Safety Instructions:
-
Always notify building security, the fire alarm monitoring station, and local fire safety officers before placing the SD-TDV50T-E valve into Test or Drain mode to prevent unintended emergency dispatches.
-
Never leave the test and drain valve partially open; return the handle firmly to the Off position after testing and verify zero leakage through the sight glass.
8. FAQ Section
Q: What is the price of Shield 100 mm (4″) Sprinkler Zone Control Valve Set in Bangladesh? A: Pricing for the Shield 100 mm (4″) UL/FM Sprinkler Zone Control Valve Set depends on exact configuration requirements and project order volume. Contact loopshop.com.bd for a formal BDT quotation.
Q: Where can I buy Shield Sprinkler Zone Control Valve Set (SD-TDV50T-E) in Bangladesh? A: You can source genuine Shield UK fire sprinkler valves and zone control assemblies online at loopshop.com.bd or directly through Loop Engineering, with nationwide delivery across Dhaka, Gazipur, Chattogram, and Narayanganj.
Q: What warranty does this product have? A: This assembly is backed by a standard manufacturer defect warranty supported through Loop Shop. Reach out to our engineering sales team with your project BOQ for detailed warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its corrosion-resistant forged brass test/drain valve, PTFE seats, and coated main valve components are engineered to withstand humid, warm riser rooms and varying water conditions in Bangladesh.
Q: How to install this product? A: Mount the 100 mm (4″) isolation butterfly valve, water flow switch, pressure gauge, and SD-TDV50T-E test & drain valve in sequence on the zone branch line, connect the supervisory and flow switches to the FACP, and route the drain outlet to an open drain pipe.
Q: What is the function of the SD-TDV50T-E valve in this set? A: The Shield SD-TDV50T-E combines a calibrated sprinkler test orifice, visual sight glass, and full-bore zone drain into a single 3-position ball valve, saving piping space and simplifying NFPA 25 flow testing.
Q: Are all components in this zone control set UL/FM certified? A: Yes, the Shield UK zone control valve set is built with UL Listed and FM Approved components to meet NFPA 13 and Bangladesh factory audit requirements.
Q: What is the maximum working pressure of this assembly? A: The assembly is rated for a maximum working pressure of 300 PSI (20.7 bar), making it suitable for high-rise buildings and pumped industrial sprinkler networks.
Q: Can this valve set connect to an addressable fire alarm panel? A: Yes. Both the butterfly valve’s supervisory tamper switch and the water flow detector switch provide dry-contact outputs that connect directly to addressable monitor modules on any standard FACP.
Q: Why is a 100 mm (4″) size commonly used for zone control valves? A: A 100 mm (4″) nominal pipe size is the industry standard for feeding individual floor sprinkler mains in multi-story commercial buildings and large RMG factory production floors

Reviews
There are no reviews yet.