Shield SD-WFD30 80mm (3″) UL/FM Water Flow Switch for Sprinkler Systems

                                                          • Primary Purpose: Detects sustained water movement inside 150 mm (6-inch) wet fire sprinkler pipes and transmits an immediate electrical alarm signal to the fire alarm control panel.

                                                          • Important Specifications: Model SD-WFD80, 150 mm (6″) pipe size, UL Listed & FM Approved, weather-resistant NEMA 4 enclosure, and adjustable mechanical retard timer (0–90 seconds).

                                                          • Customer Benefits: Prevents false alarms caused by water pressure surges while ensuring rapid fire sprinkler activation alerts and code-compliant life safety monitoring.

                                                          • Bangladesh Market Relevance: Essential for RMG textile factories, pharmaceutical plants, warehouses, and commercial high-rises in Bangladesh requiring strict NFPA 13, UL/FM, and factory safety audit compliance.

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-2 Category Tags: , , , , , , , , , , Brand:

Description

Product Overview

What is this product?The Shield SD-WFD30 is a vane-type electromechanical water flow detector designed specifically for 80 mm (3-inch) steel fire sprinkler piping. Carrying dual UL Listed and FM Approved certifications, it acts as the critical interface between hydraulic fire suppression piping and electronic fire alarm systems.

How does it work?A flexible polyethylene paddle (vane) extends into the water stream through a drilled opening in the 3-inch pipe. When a sprinkler head opens or a test-and-drain valve is activated at a flow rate of 4–10 GPM (15–38 LPM), water flow deflects the vane. This movement triggers a sealed mechanical pneumatic retard (time delay) mechanism. Once the flow persists past the field-adjustable delay window, the switch actuates two synchronized SPDT microswitches to alert both the central fire alarm panel and local notification appliances.

Who needs this product? MEP contractors, fire protection engineers, RMG factory compliance managers, and commercial building operators designing or maintaining wet-pipe sprinkler zones.

Why is it useful in Bangladesh? Municipal water fluctuations and pump start-up pressure surges are common in industrial zones across Dhaka, Gazipur, Chattogram, and Narayanganj. The SD-WFD30’s built-in mechanical retard unit filters out transient pressure spikes to prevent nuisance false alarms while ensuring strict compliance with NFPA 13 and Bangladesh fire safety inspections.

Key Features

  • UL Listed & FM Approved: Certified to international fire protection standards for high-reliability sprinkler monitoring.

  • Built-In Pneumatic Time Delay: Field-adjustable mechanical retard mechanism eliminates false alarms from transient pressure surges or trapped air.

  • Dual Synchronized SPDT Switches: Two sets of Single-Pole Double-Throw contacts provide 100% synchronized signaling to the Fire Alarm Control Panel and local alarm bells.

  • 450 PSI High Working Pressure: Heavy-duty construction withstands high static and surge pressures up to 450 PSI and flow velocities up to 18 FPS (5.5 m/s).

  • Tamper-Resistant Enclosure: Equipped with tamper-resistant cover screws and corrosion-resistant fusion-bonded epoxy/enamel coating for indoor and outdoor durability.

  • Field-Replaceable Components: Both the sealed retard mechanism and SPDT switch block can be serviced or replaced in the field without draining the sprinkler riser.

Technical Advantages

  • False-Alarm Immunity: Sealed pneumatic retard chamber resists dust and contaminants while absorbing water hammer and riser vibrations.

  • High Electrical Switching Capacity: Rated at 8A @ 250VAC, 3A @ 24VDC, and 2.5A @ 30VDC, allowing direct switching of conventional NAC circuits, addressable monitor modules, or local bells.

  • Corrosion-Protected Housing: Fusion-bonded epoxy interior and exterior finish resists moisture and humidity in tropical pump rooms and warehouse ceilings.

  • Easy Maintenance & Inspection: Clear terminal block markings, dual conduit entrances, and visual actuation indicators simplify commissioning and annual NFPA 25 testing.

Applications

  • RMG & Textile Factories: Zonal sprinkler monitoring across sewing floors, dyeing units, and finished-goods warehouses.

  • Commercial High-Rises: Floor-by-floor sprinkler water flow supervision in office towers, shopping malls, and hotels.

  • Industrial & Pharmaceutical Plants: Cleanrooms, chemical storage facilities, and manufacturing lines requiring UL/FM fire detection.

  • Project Installations: New NFPA 13 wet-pipe sprinkler installations, zone control valve assemblies, and fire safety retrofits.

Why Choose This Product?

  • Verified Global Approvals: Dual UL and FM certifications guarantee acceptance by international buyers, insurers, and local fire authorities.

  • Engineered for Riser Stability: Maintains accurate, repeatable tripping performance even during large water in-rushes and riser vibrations.

  • Lower Lifecycle Maintenance Cost: Field-replaceable retard and switch modules eliminate the need to replace the entire saddle assembly during routine servicing.

  • Local Availability in Bangladesh: Supplied with technical sizing support and fast nationwide delivery through loopshop.com.bd.

4. Technical Specification Table

Specification Details
Model SD-WFD30
Brand Shield
Nominal Pipe Size 80 mm (3 Inch)
Certifications UL Listed / FM Approved
Working Pressure Rating 450 PSI (31 Bar)
Maximum Flow Surge 18 FPS (5.5 m/s)
Flow Sensitivity Range 4 – 10 GPM (15 – 38 LPM)
Switch Contacts Two Sets of Synchronized SPDT
Contact Rating 8A @ 250VAC; 3A @ 24VDC; 2.5A @ 30VDC
Time Delay Mechanism Sealed Mechanical Pneumatic Retard (Field-Adjustable)
Operating Temperature 0°C to 68°C (32°F to 154°F)
Enclosure Finish Fusion-Bonded Epoxy / Enamel Coated (Indoor & Outdoor)
Compatible Piping Schedule 10 to Schedule 40 Steel Sprinkler Pipe (3″ / 80 mm)

5. Features List

  • ✓ UL Listed and FM Approved for 80 mm (3″) fire sprinkler systems

  • ✓ Built-in adjustable pneumatic retard prevents surge-induced false alarms

  • ✓ Dual synchronized SPDT microswitches for FACP and local bell activation

  • ✓ High 450 PSI static working pressure rating

  • ✓ Tamper-resistant cover screws for enhanced system security

  • ✓ Fusion-bonded epoxy corrosion protection for indoor and outdoor use

  • ✓ Field-replaceable retard mechanism and switch terminal block

6. Benefits For Customers

  • Eliminates Costly False Alarms: Mechanical pneumatic delay prevents nuisance evacuations and fire department dispatches caused by pump pressure fluctuations.

  • Pinpoints Fire Zones Immediately: Enables building management and fire panels to identify the exact floor or factory zone where a sprinkler head has activated.

  • Withstands Harsh Industrial Environments: Epoxy-coated housing and sealed retard unit perform reliably in high-humidity factories and warehouse spaces across Bangladesh.

  • Simplifies Audit & Testing Compliance: Fully meets NFPA 13, NFPA 25, and BNBC fire safety requirements for industrial and commercial buildings.

7. Installation & Maintenance Guide

Installation Requirements:

  • Drain the sprinkler zone completely before drilling the mounting hole in the 80 mm (3″) steel pipe using a slow-speed hole saw.

  • Clean all burrs, scale, and debris from the inside wall of the pipe around the hole so the polyethylene vane moves freely without rubbing.

  • Mount on horizontal pipe (top side preferred) or vertical pipe at least 6 inches (15 cm) away from any fitting that changes flow direction and 24 inches (60 cm) away from any valve or drain.

  • Align the directional arrow on the saddle with the water flow direction and tighten the U-bolt saddle nuts evenly.

Maintenance Tips:

  • Inspect and test water flow alarm operation quarterly or semi-annually per NFPA 25 guidelines using the zone inspector’s test-and-drain valve.

  • Verify that the pneumatic retard delay period triggers the alarm panel within the specified code timeframe (typically under 90 seconds).

  • Ensure the tamper-resistant cover remains tightly closed to protect internal microswitches from dust and moisture.

Safety Instructions:

  • Never trim or cut the polyethylene paddle/vane, as doing so alters flow sensitivity and voids UL/FM certification and warranty.

  • Disconnect alarm notification circuits or place the Fire Alarm Control Panel in test mode before conducting live flow tests to avoid unintended building evacuation.

  • Always use the supplied tamper-resistant wrench to secure the housing cover after wiring.

8. FAQ Section

Q: What is the price of Shield SD-WFD30 Water Flow Switch in Bangladesh? A: The price of the Shield SD-WFD30 80 mm (3″) UL/FM Water Flow Switch in Bangladesh depends on order quantity and current import rates. Visit loopshop.com.bd or request a formal quotation from our engineering sales team for the latest BDT price.

Q: Where can I buy Shield SD-WFD30 Water Flow Switch in Bangladesh? A: You can order genuine Shield SD-WFD30 water flow detectors directly from loopshop.com.bd, with fast delivery available across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial districts in Bangladesh.

Q: What warranty does this product have? A: The Shield SD-WFD30 is backed by a standard manufacturer warranty against defects in materials and workmanship through Loop Shop. Contact our team for project-specific warranty documentation.

Q: Is this suitable for the Bangladesh climate? A: Yes. With an operating temperature range of 0°C to 68°C, a sealed dust-immune retard mechanism, and fusion-bonded epoxy corrosion coating, it is well suited for Bangladesh’s humid tropical environment.

Q: How to install the Shield SD-WFD30 water flow switch?A: Drain the 3-inch sprinkler pipe, drill the specified mounting hole, smooth the internal pipe edges, roll and insert the polyethylene vane with the saddle arrow pointing in the flow direction, and tighten the saddle strap evenly.

Q: What does the built-in time delay do on the SD-WFD30?A: The mechanical pneumatic retard delays switch actuation for a set period so brief water surges, pump start-ups, or trapped air bubbles do not cause false fire alarms.

Q: Can the Shield SD-WFD30 connect to an addressable fire alarm system? A: Yes. Its dual SPDT dry contacts connect directly to addressable monitor modules from brands like Simplex, Edwards, Notifier, Hochiki, or GST, as well as conventional fire alarm panels.

Q: What is the minimum flow rate required to trigger this flow switch?A: The Shield SD-WFD30 is calibrated to trigger within a flow sensitivity range of 4 to 10 GPM (15 to 38 LPM).

Q: What pipe sizes and schedules are compatible with the SD-WFD30? A: Model SD-WFD30 is engineered specifically for 80 mm (3-inch) Schedule 10 through Schedule 40 steel sprinkler pipes.

Q: Is this flow switch approved for RMG factory fire safety inspections in Bangladesh? A: Yes. Because it is both UL Listed and FM Approved, it meets international fire code requirements (NFPA 13) accepted by factory safety auditors and local authorities in Bangladesh

Reviews

There are no reviews yet.

Be the first to review “Shield SD-WFD30 80mm (3″) UL/FM Water Flow Switch for Sprinkler Systems”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support