Shield SD-WFD80 100mm (4″) UL/FM Water Flow Switch for Fire Sprinklers

                                                        • Primary Purpose: Detects sustained water movement inside 100 mm (4-inch) fire sprinkler pipes and transmits an immediate alarm signal to the Fire Alarm Control Panel (FACP).

                                                        • Important Specifications: Model SD-WFD80, 100 mm (4″) nominal pipe size, UL Listed and FM Approved, dual SPDT switch contacts, and adjustable pneumatic retard mechanism.

                                                        • Customer Benefits: Eliminates false alarms caused by water pressure surges while ensuring rapid, reliable fire zone identification and alarm activation.

                                                        • Bangladesh Market Relevance: Essential for BNBC, NFPA 13, and industrial fire safety audit compliance across RMG factories, warehouses, and high-rise buildings in Bangladesh.

                                                        .

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1 Category Tags: , , , , , , , , , , Brand:

Description

Product Overview

What is this product? The Shield SD-WFD80 is a vane-type electromechanical water flow detector engineered specifically for 100 mm (4-inch) wet-pipe automatic fire sprinkler systems, carrying both UL Listing and FM Approval.

How does it work? When a fire sprinkler head activates due to heat, water begins flowing through the 100 mm riser or branch main, deflecting the flexible polymer paddle inserted into the pipe. This mechanical deflection triggers a built-in pneumatic retard timer (adjustable to prevent false trips from transient pressure surges) before actuating dual SPDT micro-switches that send an alarm signal to the building’s Fire Alarm Control Panel (FACP) and local notification bells.

Who needs this product? Fire protection contractors, MEP engineers, factory safety managers, and commercial building owners installing or upgrading wet sprinkler systems.

Why is it useful in Bangladesh? Industrial garment factories (RMG), textile mills, pharmaceutical plants, and commercial towers in Dhaka, Gazipur, Chattogram, and Narayanganj must comply with strict NFPA 13, BNBC, and international buyer fire safety standards. The Shield SD-WFD80 provides reliable zone-level sprinkler monitoring with UL/FM certification required to pass safety inspections.

Key Features

  • UL Listed & FM Approved: Dual international certification verifying strict performance, endurance, and reliability for fire protection service.

  • 100 mm (4-Inch) Pipe Compatibility: Precision-molded flexible vane sized specifically for 4-inch Schedule 10 through Schedule 40 steel sprinkler piping.

  • Adjustable Pneumatic Retard: Built-in mechanical time-delay mechanism prevents false alarms caused by municipal water surges or pump start-up spikes.

  • Dual SPDT Micro-Switches: Provides two independent sets of Form-C contacts for simultaneous signaling to the FACP and auxiliary equipment (such as elevator recall or HVAC shutdown).

  • Tamper-Resistant Enclosure: Rugged die-cast aluminum housing secured with tamper-resistant cover screws to prevent unauthorized access.

  • Visual Switch Activation: Clear internal indicator and mechanical lever movement simplify commissioning and annual flow testing.

Technical Advantages

  • False-Alarm Immunity: Pneumatic retard delay filters out momentary pressure fluctuations common in municipal and booster-fed water networks without delaying genuine fire alarms.

  • Durable Corrosion-Resistant Build: Non-corrosive flexible vane and sealed housing withstand continuous immersion in stagnant fire-sprinkler water.

  • Easy Maintenance & Field Adjustment: Accessible retard dial and spacious wiring terminal block speed up installation, calibration, and routine inspection.

  • High Electrical Versatility: Dual SPDT contacts support both conventional fire alarm zone modules and addressable monitor modules.

Applications

  • Industrial & RMG Factories: Wet sprinkler zone risers and floor branch lines in textile factories, garments, and logistics warehouses.

  • Commercial Buildings: Shopping malls, high-rise corporate offices, hotels, and convention centers.

  • Healthcare & Institutional: Hospitals, universities, and pharmaceutical manufacturing facilities.

  • Project Installations: New NFPA 13 fire sprinkler system installations, floor-by-floor alarm zoning, and factory compliance retrofits.

Why Choose This Product?

  • Verified Global Certification: Carries both UL Listing and FM Approval, ensuring smooth acceptance by fire safety auditors and consultants.

  • Consistent Detection Accuracy: Engineered to trigger reliably at sustained low flow rates while ignoring harmless hydraulic surges.

  • Cost-Effective Compliance: Delivers dependable international-grade fire detection performance at a competitive project budget.

  • Local Availability via Loop Shop: Supplied in Bangladesh with technical verification and project support from Loop Engineering & Loop Shop.

4. Technical Specification Table

Specification Details
Model SD-WFD80
Brand Shield
Product Type Vane-Type Water Flow Detector / Switch
Nominal Pipe Size 100 mm (4 Inch)
Pipe Compatibility Steel Pipe (Schedule 10 to Schedule 40)
Certifications UL Listed, FM Approved
Switch Contacts Dual SPDT (2 x Form-C Micro-Switches)
Retard Mechanism Adjustable Pneumatic Time Delay
Mounting Orientation Horizontal or Vertical Pipe (Upward Flow)
Enclosure Material Die-Cast Metal Housing with Tamper-Resistant Cover
System Application Wet-Pipe Automatic Fire Sprinkler Systems

5. Features List

  • ✓ UL Listed & FM Approved for fire sprinkler systems

  • ✓ Sized for 100 mm (4″) Schedule 10 to Schedule 40 steel pipes

  • ✓ Adjustable pneumatic retard prevents false alarms from pressure surges

  • ✓ Dual SPDT (Form-C) contacts for FACP and auxiliary control

  • ✓ Rugged die-cast housing with tamper-resistant cover screws

  • ✓ Flexible, non-corrosive vane for long-term underwater durability

  • ✓ Suitable for horizontal or vertical upward-flow mounting

6. Benefits For Customers

  • Prevents Costly False Alarms: Adjustable retard delay eliminates nuisance alarms triggered by pump pressure fluctuations.

  • Rapid Fire Zone Pinpointing: Alerts facility teams immediately to the exact floor or zone where a sprinkler head has activated.

  • Passes Fire Safety Audits: Full UL/FM certification meets BNBC, NFPA 13, and international buyer inspection mandates in Bangladesh.

  • Built for Local Conditions: Sealed enclosure protects internal micro-switches against dust and high humidity in Bangladesh pump rooms and factory floors.

7. Installation & Maintenance Guide

Installation Requirements:

  • Drill a clean, burr-free mounting hole on the 100 mm (4″) steel pipe strictly following the manufacturer’s hole-saw template, ensuring placement at least 6 inches (150 mm) from fittings and 24 inches (600 mm) from valves or elbows.

  • Mount on horizontal pipe or vertical pipe with upward water flow only (never mount on downward-flowing vertical risers).

  • Verify the directional flow arrow on the housing matches actual water flow direction, and tighten the U-bolt evenly to compress the saddle gasket without over-torquing.

Maintenance Tips:

  • Test water flow quarterly or semi-annually by opening the Inspector’s Test Valve at the end of the sprinkler branch line and verifying alarm activation within the required NFPA 13 time window.

  • Inspect the enclosure cover gasket, conduit entry seals, and mounting U-bolt during routine fire safety checks.

  • Ensure the pneumatic retard dial remains securely set and free of dust or moisture.

Safety Instructions:

  • Drain and depressurize the sprinkler zone pipe completely before drilling the pipe or removing an existing water flow switch.

  • Disconnect fire alarm circuit power or place the FACP in test/bypass mode prior to wiring or servicing the micro-switch terminals.

8. FAQ Section

Q: What is the price of Shield Water Flow Switch 100 mm (4″) SD-WFD80 in Bangladesh? A: The price of the Shield SD-WFD80 100 mm (4″) UL/FM Water Flow Switch in Bangladesh depends on order volume and current import rates. Contact loopshop.com.bd for the latest BDT unit price or project quotation.

Q: Where can I buy Shield Water Flow Switch 100 mm (4″) SD-WFD80 in Bangladesh? A: You can order the genuine Shield SD-WFD80 online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial zones in Bangladesh.

Q: What warranty does this product have? A: The Shield SD-WFD80 includes a manufacturer defect warranty backed by Loop Shop. Contact our team with your project details for complete warranty documentation.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its sealed die-cast metal housing and corrosion-resistant internal paddle are built to withstand high humidity, dust, and elevated ambient temperatures in Bangladesh factories and commercial buildings.

Q: How to install this product? A: Cut the specified circular hole in a 100 mm (4″) wet sprinkler pipe, insert the flexible paddle aligned with the flow arrow, secure the saddle with the U-bolt, and wire the SPDT contacts to your fire alarm monitor module.

Q: Is the Shield SD-WFD80 UL Listed and FM Approved? A: Yes, it carries both UL Listing and FM Approval, making it suitable for NFPA 13 and international fire audit requirements.

Q: Can this water flow switch be installed on a vertical pipe? A: Yes, it can be mounted on either horizontal pipes or vertical pipes where water flows upward. Do not install it where water flows downward.

Q: Why does the SD-WFD80 have a pneumatic retard timer? A: The adjustable retard delays switch activation briefly so momentary water pressure surges from municipal lines or jockey pumps do not trigger false fire alarms.

Q: Does it work with addressable fire alarm systems? A: Yes. Its dual SPDT dry contacts connect directly to addressable monitor modules from brands like Simplex, Edwards, GST, Hochiki, or Notifier, as well as conventional FACPs.

Q: Can it be used in dry-pipe or deluge sprinkler systems? A: No. Vane-type water flow switches like the SD-WFD80 are designed exclusively for wet-pipe sprinkler systems, as high-velocity air/water surges in dry systems can damage the paddle.

Reviews

There are no reviews yet.

Be the first to review “Shield SD-WFD80 100mm (4″) UL/FM Water Flow Switch for Fire Sprinklers”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581