Description
Product Overview
What is this product? The Shield SD-WFD20 is a 2-inch (50 mm) vane-type water flow detector engineered for wet-pipe automatic fire sprinkler systems. It carries both UL Listing and FM Approval for commercial and industrial fire protection installations.
How does it work? A flexible polymer paddle (vane) extends into the 2-inch sprinkler branch or riser pipe. When a sprinkler head opens due to fire, water flows through the pipe and deflects the paddle. This mechanical movement activates a built-in adjustable retard mechanism that delays signaling briefly to ignore momentary water surges, before triggering two internal Single-Pole Double-Throw (SPDT) switches to alert the fire alarm panel and local notification bells.
Who needs this product? Fire safety contractors, MEP engineers, industrial facility managers, and building owners installing or upgrading wet-pipe sprinkler networks.
Why is it useful in Bangladesh? Industrial plants, garment factories, warehouses, and commercial complexes in Dhaka, Gazipur, Chattogram, and Narayanganj must adhere to strict NFPA 13, BNBC, and international buyer fire safety standards. Fluctuating municipal and pump-room line pressures in Bangladesh frequently cause false alarms on unretarded switches—making the Shield SD-WFD20’s adjustable retard timer ideal for reliable, audit-ready performance.
Key Features
-
Dual UL/FM Certification: Officially UL Listed and FM Approved for reliable performance in code-compliant fire sprinkler networks.
-
Adjustable Retard Mechanism: Built-in 0 to 90-second pneumatic/mechanical delay eliminates false alarms triggered by transient pressure spikes or water hammer.
-
Dual SPDT Dry Contact Switches: Equipped with two independent Form C micro-switches for simultaneous fire alarm panel signaling and auxiliary control functions.
-
2-Inch (50 mm) Pipe Compatibility: Precision-sized saddle and paddle assembly tailored for standard 2″ (DN50) Schedule 10 and Schedule 40 steel sprinkler pipes.
-
Tamper-Resistant Enclosure: Rugged die-cast metal housing secured with tamper-resistant cover screws to prevent unauthorized access.
-
Visual & Tactile Retard Dial: Easy-to-read dial allows fast on-site delay adjustment during system commissioning and testing.
Technical Advantages
-
False-Alarm Immunity: Adjustable retard delay filters out pressure surges from jockey pump cycling or municipal supply fluctuations.
-
Corrosion-Resistant Wetted Parts: Durable non-corrosive polymer vane and sealed actuator stem withstand stagnant sprinkler water over long service periods.
-
Dual-Circuit Versatility: Two synchronized SPDT switches allow separate wiring to the addressable monitor module and local alarm bell or BMS.
-
Service-Friendly Switch Module: Internal switch assembly can be inspected or replaced without draining the entire fire sprinkler riser.
Applications
-
Industrial & RMG Factories: Zone flow monitoring in garment factories, spinning mills, dyeing units, and logistics warehouses.
-
Commercial Buildings: Floor-by-floor sprinkler zone detection in shopping malls, corporate towers, and hotels.
-
Healthcare & Institutions: Hospitals, pharmaceutical plants, and educational campuses requiring zoned sprinkler annunciation.
-
Project Installations: New NFPA 13 wet-pipe sprinkler installations, riser manifolds, and fire safety retrofits.
Why Choose This Product?
-
Globally Recognized Approvals: UL and FM certifications ensure smooth acceptance by fire safety inspectors and international compliance auditors.
-
High Operational Reliability: Proven vane-and-retard architecture minimizes nuisance dispatches while guaranteeing rapid alarm activation during real fire events.
-
Cost-Effective Zone Control: Provides accurate floor or zone-level sprinkler activation tracking without expensive inline flow meters.
-
Local Availability in Bangladesh: Supplied by loopshop.com.bd with technical documentation, engineering support, and nationwide delivery.
4. Technical Specification Table
| Specification | Details |
| Model | SD-WFD20 |
| Brand | Shield |
| Product Type | Vane-Type Water Flow Detector Switch |
| Nominal Pipe Size | 2 Inch (50 mm / DN50) |
| Approvals & Certifications | UL Listed, FM Approved |
| Switch Contact Type | Dual SPDT (Form C) Micro-Switches |
| Retard Delay Range | Adjustable (0 – 90 Seconds) |
| System Compatibility | Wet-Pipe Fire Sprinkler Systems (Schedule 10 / 40 Steel Pipe) |
| Enclosure Construction | Heavy-Duty Die-Cast Metal Housing with Tamper Screws |
| Vane Material | Flexible Corrosion-Resistant Polymer |
| Mounting Method | Saddle Clamp on Drilled Pipe Hole |
5. Features List
-
✓ UL Listed and FM Approved for fire sprinkler service
-
✓ Fits standard 2″ (50 mm / DN50) wet-pipe sprinkler lines
-
✓ Adjustable 0–90 second retard timer prevents false alarms
-
✓ Dual SPDT (Form C) contacts for FACP and auxiliary signaling
-
✓ Rugged die-cast enclosure with tamper-resistant cover fasteners
-
✓ Non-corrosive flexible paddle for long-term immersion
-
✓ Simple saddle-mount installation on Schedule 10 and 40 pipes
6. Benefits For Customers
-
Eliminates Nuisance Alarms: Built-in retard delay ignores brief water surges caused by jockey pump starts or supply pressure shifts.
-
Pinpoints Fire Locations Quickly: Identifies the exact sprinkler zone or floor where water is flowing, speeding up emergency response.
-
Meets Factory Audit Standards: UL/FM markings satisfy NFPA 13, BNBC, and international industrial safety inspection criteria in Bangladesh.
-
Low Maintenance Overhead: Durable sealed housing and replaceable switch module keep lifecycle maintenance costs minimal.
7. Installation & Maintenance Guide
Installation Requirements:
-
Mount on a straight horizontal or vertical section of 2″ (50 mm) wet-pipe sprinkler piping, maintaining at least 6 inches (150 mm) clearance from fittings, valves, or elbows on the upstream side.
-
Drill the exact manufacturer-specified hole size cleanly into the pipe wall, deburr the inner edge, insert the folded paddle smoothly, and tighten the U-bolt saddle evenly.
-
Ensure the directional flow arrow on the housing matches the actual direction of water flow.
Maintenance Tips:
-
Test water flow activation quarterly or semi-annually by opening the Inspector’s Test Valve at the end of the sprinkler branch line and verifying alarm receipt within the set retard time.
-
Inspect the enclosure gasket and conduit entry periodically to prevent moisture ingress in humid pump rooms or factory floors.
-
Check that the paddle moves freely without hitting internal pipe welds or scale buildup.
Safety Instructions:
-
Always close the zone control valve and drain the sprinkler pipe section completely before drilling the pipe or removing the flow switch saddle.
-
Disconnect electrical power from the Fire Alarm Control Panel monitor circuit before wiring or servicing the internal SPDT terminals.
8. FAQ Section
Q: What is the price of Shield SD-WFD20 2″ Water Flow Switch in Bangladesh? A: The price of the Shield SD-WFD20 2″ (50 mm) UL/FM Water Flow Switch in Bangladesh depends on order quantity and current stock. Visit loopshop.com.bd or contact our sales team for an exact BDT price quote.
Q: Where can I buy Shield SD-WFD20 Water Flow Switch in Bangladesh? A: You can buy the genuine Shield SD-WFD20 UL/FM Water Flow Switch online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, and all over Bangladesh.
Q: What warranty does this product have? A: The Shield SD-WFD20 includes a standard manufacturer warranty against manufacturing defects through Loop Shop. Contact our team for project-specific warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its sealed die-cast metal enclosure and non-corrosive internal paddle are built to withstand high ambient humidity and warm indoor environments across Bangladesh.
Q: How to install this product? A: Drain the 2″ sprinkler pipe, drill the required mounting hole at least 6 inches away from any fitting, insert the paddle aligned with the flow arrow, secure the U-bolt saddle, and wire the SPDT contacts to your fire alarm monitor module.
Q: What does the retard timer do on the Shield SD-WFD20? A: The retard timer introduces an adjustable delay (0 to 90 seconds) before triggering the alarm switch, preventing false alarms caused by momentary water pressure surges.
Q: Can this water flow switch be used on dry-pipe sprinkler systems? A: No. Vane-type water flow switches like the SD-WFD20 are designed exclusively for wet-pipe sprinkler systems where the pipe remains continuously filled with water.
Q: Is the Shield SD-WFD20 compatible with addressable fire alarm panels? A: Yes. Its dry-contact SPDT micro-switches connect directly to standard addressable monitor modules from any major fire alarm brand.
Q: Does this product carry both UL and FM approvals? A: Yes, the Shield SD-WFD20 is both UL Listed and FM Approved for fire protection sprinkler systems.
Q: What pipe schedules does the 50 mm (2″) model fit? A: It is designed to fit standard 2-inch (DN50) Schedule 10 and Schedule 40 steel fire sprinkler pipes.