Shield Pressure Switch SD-PS1001 — UL/FM

                    • Primary Function: Monitors water pressure changes in wet, dry, deluge, and pre-action automatic fire sprinkler systems to trigger immediate alarm signals.

                    • Certified Compliance: UL Listed and FM Approved alarm pressure switch engineered for strict life-safety and international fire protection standards.

                    • Key Specifications: Features a rugged die-cast housing, NPT threaded pressure connection, adjustable trip point, and SPDT/DPDT micro-switch contacts.

                    • Operational Advantage: Delivers rapid, reliable electrical switching upon pressure drop or rise, preventing false alarms and ensuring swift emergency response.

                    • Bangladesh Market Suitability: Built for garment factories, commercial high-rises, and industrial plants across Bangladesh requiring RSC, Accord/Alliance, and BNBC fire safety compliance.

Best Price Guaranteed

Description

Product Overview

The Shield SD-PS1001 is a heavy-duty, UL Listed and FM Approved alarm pressure switch designed specifically for automatic fire sprinkler installations. Installed on the alarm port of wet alarm check valves, dry pipe valves, or deluge systems, it detects abnormal pressure fluctuations caused by sprinkler head activation or system pressure loss and converts that mechanical pressure change into an electrical signal for the Fire Alarm Control Panel (FACP).

For facility managers, MEP contractors, and fire safety engineers in Bangladesh, certified fire protection components are essential for passing safety audits. Whether outfitting a readymade garment (RMG) factory in Gazipur or a commercial tower in Dhaka, the SD-PS1001 ensures reliable alarm initiation that meets Bangladesh National Building Code (BNBC) and international inspection requirements.

Key Features

  • Dual International Certification: UL Listed and FM Approved for critical fire protection and life-safety signaling applications.

  • Precision Pressure Sensing: Sensitive diaphragm mechanism accurately responds to preset pressure increases or drops within the sprinkler riser.

  • Versatile System Compatibility: Engineered for wet pipe, dry pipe, pre-action, and deluge sprinkler risers.

  • Tamper-Resistant Enclosure: Rugged weather-resistant housing with tamper-proof cover screws protects internal switching components from unauthorized access.

  • High-Visibility Status & Wiring: Spacious internal wiring chamber with clearly marked terminals simplifies field connection to addressable monitor modules or conventional FACP zones.

  • Field-Adjustable Setpoint: Allows qualified technicians to fine-tune the actuation pressure threshold to match specific system operating pressures.

Technical Advantages

  • High Reliability Under Pressure: Heavy-duty pressure-sensing element withstands continuous static line pressure and hydraulic surges without diaphragm fatigue.

  • Durable Industrial Construction: Corrosion-resistant metallic base and protective enclosure resist dust, moisture, and harsh mechanical room conditions.

  • Fail-Safe Alarm Signaling: Positive snap-action micro-switches ensure clean contact closure without chattering, preventing missed alarms or false supervisory triggers.

  • Low Maintenance Requirement: Sealed sensing assembly requires minimal routine servicing beyond standard NFPA 25 periodic testing.

Applications

  • Industrial & RMG Factories: Textile mills, knitwear factories, pharmaceuticals, and manufacturing plants requiring UL/FM fire suppression systems.

  • Commercial High-Rises: Shopping malls, corporate offices, hotels, and hospitals in Dhaka, Chattogram, and across Bangladesh.

  • Warehouses & Logistics Hubs: Cold storage facilities, dry-pipe storage racks, and distribution centers.

  • Project Installations: New MEP fire protection contracting, hydrant/sprinkler riser upgrades, and fire safety remediation projects.

Why Choose This Product?

  • Audit-Ready Compliance: Carries authentic UL and FM markings required by fire safety inspectors, insurance underwriters, and industrial compliance bodies in Bangladesh.

  • Proven Engineering Performance: Consistent repeatability across thousands of pressure cycles guarantees dependable operation during an actual fire emergency.

  • Cost-Effective Protection: Combines long service life with straightforward installation, reducing commissioning labor and lifecycle replacement expenses.

  • Trusted Local Support: Backed by Loop Engineering and Loop Shop Bangladesh for genuine sourcing, technical consultation, and project supply support.

================================================

4. Technical Specification Table

Specification Details
Model SD-PS1001
Brand Shield
Product Type Fire Sprinkler Alarm Pressure Switch
Certifications UL Listed, FM Approved
System Compatibility Wet, Dry, Deluge, and Pre-Action Sprinkler Systems
Connection Type Male NPT Threaded Pressure Port
Switch Contact Type Snap-Action Micro-Switch (SPDT / DPDT)
Enclosure Protection Weather-Resistant / Tamper-Resistant Housing
Application Media Water / Air (Sprinkler Riser Supervisory & Alarm)
Mounting Position Vertical / Upright on Alarm Trim Line

================================================

5. Features List

✓ UL Listed and FM Approved for fire sprinkler systems

✓ High-accuracy pressure-sensing diaphragm mechanism

✓ Compatible with wet, dry, pre-action, and deluge valves

✓ Rugged, corrosion-resistant, and tamper-proof enclosure

✓ Snap-action contacts for reliable FACP signal transmission

✓ Field-adjustable pressure trip point

✓ Easy terminal wiring for fast commissioning

✓ Long operational lifespan with minimal maintenance

================================================

6. Benefits For Customers

  • Ensures Regulatory & Audit Approval: Helps factories and commercial buildings pass fire safety inspections with recognized UL/FM certified hardware.

  • Faster Emergency Response: Immediately alerts the central fire alarm panel the moment sprinkler water flow begins, minimizing fire and water damage.

  • Reduces False Alarms: Stable snap-action switching prevents nuisance alarms caused by minor municipal or pump pressure fluctuations.

  • Built for Bangladesh Conditions: Performs reliably in high-humidity, high-temperature pump rooms and industrial utility spaces common across Bangladesh.

================================================

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the Shield SD-PS1001 upright on the alarm trim line or dedicated pressure port of the sprinkler riser using approved thread sealant (PTFE tape or pipe dope) on the male NPT threads only—avoid getting sealant inside the pressure orifice.

  • Ensure an isolation valve or test connection is installed in accordance with NFPA 13 and local fire codes to allow periodic testing without draining the entire riser.

  • Route electrical conduit into the enclosure using a suitable cable gland to maintain environmental sealing, and wire the contacts to the Fire Alarm Control Panel (FACP) monitor module per the internal wiring diagram.

Maintenance Tips:

  • Inspect and test the pressure switch quarterly or semi-annually in accordance with NFPA 25 inspection schedules using the system alarm test valve.

  • Check the enclosure cover, conduit entry, and electrical terminals during routine maintenance to ensure they remain dry, tight, and free of dust or corrosion.

  • Verify that the actuation pressure matches the design specification of the sprinkler system after any major pump or valve servicing.

Safety Instructions:

  • Always depressurize the sprinkler alarm line and isolate electrical power from the monitoring circuit before removing, adjusting, or servicing the pressure switch.

  • Notify the building security team, facility manager, and central monitoring station before performing live pressure tests to prevent unintended emergency dispatch.

  • Installation and calibration must only be performed by a qualified fire protection technician or licensed MEP engineer.

================================================

8. FAQ Section

Q: What is the price of Shield Pressure Switch SD-PS1001 in Bangladesh?

A: The price of the Shield SD-PS1001 UL/FM Pressure Switch in Bangladesh varies depending on order quantity, project requirements, and current import rates. Contact Loop Shop Bangladesh (loopshop.com.bd) directly for the latest BDT quotation and bulk project pricing.

Q: Where can I buy Shield Pressure Switch SD-PS1001 in Bangladesh?

A: You can purchase genuine Shield SD-PS1001 UL/FM pressure switches online at loopshop.com.bd or order directly through Loop Engineering for commercial and industrial fire protection projects anywhere in Bangladesh, including Dhaka, Gazipur, Narayanganj, and Chattogram.

Q: Is the Shield SD-PS1001 UL Listed and FM Approved?

A: Yes, the Shield SD-PS1001 is both UL Listed and FM Approved, making it compliant with international fire protection standards and industrial safety audits in Bangladesh.

Q: What warranty does this product have?

A: The Shield SD-PS1001 is supplied against manufacturing defects under standard distributor warranty terms. Please confirm specific warranty coverage and documentation with Loop Shop Bangladesh at the time of purchase.

Q: Is this pressure switch suitable for the Bangladesh climate?

A: Yes, its corrosion-resistant construction and sealed, weather-resistant housing are well suited for the high humidity, elevated temperatures, and dusty environments found in industrial pump rooms and utility spaces across Bangladesh.

Q: Which fire sprinkler systems work with the Shield SD-PS1001?

A: It is compatible with wet pipe alarm check valves, dry pipe systems, deluge systems, and pre-action fire sprinkler installations.

Q: How to install this product?

A: Thread the switch upright into the designated NPT alarm port on the sprinkler riser using proper thread sealant, connect the conduit and signal wires to your Fire Alarm Control Panel (FACP) monitor module, and verify operation via the alarm test valve.

Q: Can the Shield SD-PS1001 connect to an addressable fire alarm system?

A: Yes, its dry snap-action contacts easily interface with addressable monitor modules from major FACP brands as well as conventional fire alarm zones.

Q: What is the difference between a pressure switch and a waterflow switch?

A: A waterflow switch uses a paddle inside the pipe to detect moving water, whereas a pressure switch like the SD-PS1001 mounts on the alarm trim line or riser port to sense pressure changes in the system.

Q: Does Loop Shop Bangladesh supply UL/FM certificates for project handover?

A: Yes, relevant product datasheets and UL/FM listing documentation can be provided upon request for corporate procurement, consultant submittal, and factory compliance audits.

Reviews

There are no reviews yet.

Be the first to review “Shield Pressure Switch SD-PS1001 — UL/FM”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581