Description
The Perkins Generator Radiator series provides authentic OEM thermal dissipation and cooling system reliability for Perkins-powered diesel generators and industrial power equipment. Consolidating high-demand radiator assemblies including 2485B280 (for 30 kVA to 45 kVA engines) and U45506590 / T430491 (for 20 kVA to 22 kVA engines), this complete cooling package is built to withstand high-ambient tropical environments. By combining high-conductivity aluminum core matrices, reinforced polymer tanks, and factory-matched fan cowls, these radiators prevent engine overheating, coolant boil-over, and high-temperature safety shutdowns across industrial facilities in Bangladesh.
Technical Specifications Table
| Product Series | Perkins Generator Radiator & Cooling Package Group |
| Consolidated Part Numbers | 2485B280 (30 kVA) & U45506590 / T430491 / 2485B284 (22 kVA) |
| Brand Portfolio | Perkins Engines |
| Core Material & Construction | High-Conductivity Brazed Aluminum Core with Heavy-Duty Reinforced Tanks |
| Engine Series Compatibility | Perkins 400 Series & Perkins 1100 Series Engines |
| Supported Engine Models | 403D-15, 404D-22, 404D-22T, 1103A-33, 1103C-33, 1104A-44, 1104C-44 |
| Supported Generator Ratings | 20 kVA, 22 kVA, 30 kVA, 35 kVA, 40 kVA, 45 kVA Generator Sets |
| FG Wilson Cross-References | FG Wilson 10000-00436, 10000-55272, 10000-54916, 998-515 |
| 2485B280 Dimensions | Height: 570 mm (22.5 in) | Length: 762.6 mm (30.0 in) | Hose ID: 42.5 mm (1.7 in) |
| Fan Cowl Shroud Clearance | 477 mm (18.7 in) Precision Fan Aperture for Maximum Suction Velocity |
| Manufacturing Standards | ISO9001 & TS16949 Certified 100% Leak & Pressure Tested |
| Warranty Coverage | 12-Month Standard Manufacturer Replacement Warranty |
⚙️ Engineering & Technical Compatibility Verification
Verify radiator core thickness, fan shroud diameter, and coolant hose alignment prior to installing the Perkins Generator Radiator. Review official cooling guidelines at Perkins Engines Official Portal for technical verification.
High-Capacity Heat Rejection & Tropicalized Generator Cooling
Continuous-duty diesel generators operate under high thermal stress inside acoustic soundproof canopies. Restricted airflow combined with high ambient summer temperatures in Bangladesh makes an efficient cooling package vital for engine survival. The Perkins Generator Radiator series utilizes high-density brazed aluminum fin arrays that maximize the surface area exposed to cooling airflow, transferring heat rapidly from the engine coolant to the atmosphere.
Each unit features a factory-integrated aerodynamic fan shroud cowl that channels incoming suction air directly across the entire core face, eliminating hot spots and dead zones. Built with vibration-resistant header plates and reinforced tank crimps, genuine Perkins radiators withstand long runtimes and continuous generator vibration without developing core tube fractures or coolant weeping, keeping your generator operating reliably at 100% prime load.
- Optimal Heat Dissipation: The Perkins Generator Radiator maintains stable engine coolant temperatures even under full 100% generator electrical loads.
- Factory-Fitted Fan Shroud: Built-in cowl channels cooling airflow across 100% of the core matrix for superior thermal performance.
- Vibration-Resistant Aluminum Core: Brazed aluminum construction resists metal fatigue, pressure pulses, and thermal shock.
- Direct Bolt-On Alignment: OE-exact mounting feet and 42.5 mm coolant connection ports ensure seamless drop-in installation.
- Extended Engine Reliability: Prevents cylinder head warping and thermal shutdowns, protecting your generator investment.
Frequently Asked Questions (FAQ)
Q1: What is the official price of the Perkins Generator Radiator in Bangladesh?
A: Radiator pricing depends on the generator capacity (22 kVA compact vs 30 kVA / 45 kVA standard cooling packages). Contact our sales engineering desk directly for an official quotation and delivery details.
Q2: Which radiator model fits a 22 kVA vs a 30 kVA Perkins generator?
A: Model U45506590 (or T430491) is designed for 20 kVA to 22 kVA Perkins 400 Series engines (403D-15, 404D-22), while model 2485B280 is engineered for 30 kVA to 45 kVA Perkins 1100 Series engines (1103A-33, 1104A-44).
Q3: What are the primary connection dimensions of the 2485B280 radiator?
A: The 2485B280 radiator features an overall length of 762.6 mm (30.0 in), a height of 570 mm (22.5 in), a 477 mm fan core diameter, and 42.5 mm coolant hose inlet/outlet ports.
Q4: Is part number 2485B280 compatible with FG Wilson generator sets?
A: Yes, part number 2485B280 is the direct cross-reference replacement for FG Wilson part number 10000-00436 on P30 to P45 generator models.
Q5: What are the common signs of a failing generator radiator?
A: Common indicators include engine high-temperature alarms on the control module, visible coolant leaks around the tank crimp seams, corroded cooling fins, or coolant boiling in the overflow bottle.
Q6: Where can I buy genuine Perkins generator radiators in Bangladesh?
A: You can purchase 100% authentic Perkins radiators, water pumps, thermostats, and cooling system maintenance parts directly from our inventory with full warranty backing.