Technical Specifications
✅ Model Number: MOD 10K TL3-X
🔌 AC Output (Grid Side – 3 Phase)
Parameter | Specification |
Rated AC Output Power | 10000W |
Max. AC Output Power | 11000W |
Nominal AC Voltage | 400V (3-phase) |
Voltage Range | 310V – 480V |
AC Frequency | 50Hz / 60Hz (auto-sensing) |
Max. Output Current | ~16A |
Power Factor | >0.99 (adjustable ±0.8) |
THD (Total Harmonic Distortion) | <3% |
☀️ PV Input (DC Side)
Parameter | Specification |
Max. DC Input Power | 15000W |
Max. DC Voltage | 1100V |
Start Voltage | 160V |
MPPT Voltage Range | 140V – 1000V |
Number of MPPTs / Strings | 2 MPPTs / 2 Strings |
Max. Current per MPPT | 13A |
Max. Short Circuit Current | 16.5A |
🌐 Efficiency
Parameter | Specification |
Max. Efficiency | 98.6% |
Euro Efficiency | 98.1% |
📡 Communication & Monitoring
| Interface | RS485, USB, WiFi (optional), GPRS (optional), LAN (optional) | | Monitoring Platforms | ShinePhone, ShineServer, ShineLink |
📐 Mechanical & Environmental
Parameter | Specification |
Dimensions (W x H x D) | 425 x 387 x 178 mm |
Weight | ~13.5 kg |
Cooling Method | Natural Convection + Smart Fan |
Protection Class | IP66 (outdoor ready) |
Operating Temperature | -25°C to +60°C |
Humidity | 0 – 100% RH (non-condensing) |
Max. Altitude | ≤4000m |
🛡️ Protection & Safety
- DC reverse polarity protection
- AC over/under voltage & frequency protection
- Anti-islanding protection
- Ground fault monitoring
- Integrated Type II SPD (Surge Protection Device) on both DC and AC sides
- Optional AFCI (Arc Fault Protection)
🧰 Special Features
- Dual MPPT for versatile PV string design
- High DC input voltage (up to 1100V) for longer strings
- Remote firmware upgrade via Shine tools
- Export limitation and zero-export supported (with accessories)
- Built-in display and status indicators
- Compatible with Growatt Smart Meter for energy control
🧾 Warranty Information
Standard Warranty: 5 Years
📦 Applications
- Mid-size residential and small commercial rooftops
- Three-phase grid-connected systems
- Projects requiring high DC/AC ratio
- Installations with different PV array orientations
Reviews