Maple Armor FW2521 Addressable Heat Detector (Fixed Temperature & Rate-of-Rise)

• Dual-Action Thermal Sensing: Combines fast-acting fixed-temperature detection (135°F / 57°C) and rate-of-rise thermal response
• Addressable Loop Loading: Consumes a single logical address supporting up to 252 devices on Maple Armor SLC circuits
• Dual 360° Status LEDs: Omnidirectional visual indicators providing clear flashing standby and steady red alarm status
• Remote Annunciation Port: Dedicated terminals for direct connection to Maple Armor FW2561-RI Remote LED indicators
• Base Versatility: Operates with FW2501 (4-inch), FW2502 (6-inch flanged), and FW2509 sounder bases (sold separately)
• Harsh Environment Ready: Purpose-built for kitchens, boiler rooms, parking structures, and dusty mechanical spaces

Best Price Guaranteed

Description

The Maple Armor FW2521 Addressable Heat Detector is a high-performance, intelligent thermal life-safety sensor engineered to protect challenging environments where airborne smoke, dust, steam, or exhaust fumes make standard optical sensors unsuitable. Driven by an advanced internal processor, the Maple Armor FW2521 Addressable Heat Detector features dual thermal detection logic combining fixed-temperature activation and rapid rate-of-rise response. Operating seamlessly on the Signaling Line Circuit (SLC) of Maple Armor FW2105 and FW2107 panels, this Maple Armor FW2521 Addressable Heat Detector occupies a single address and provides rock-solid fire protection across commercial kitchens, parking garages, and industrial boiler rooms.

Technical Specifications Table

Product Model FW2521 (Series 2 Addressable Thermal Detector)
Manufacturer & Brand Maple Armor Technologies Inc.
Country of Origin Canada
Thermal Detection Method Dual Mode: Fixed Temperature (135°F / 57.2°C) & Rate-of-Rise (15°F / 8.3°C per min)
Nominal Operating Voltage 24 VDC (Operating Voltage Range: 15.3 to 28 VDC)
Standby Current Consumption 0.16 mA @ 24 VDC
Alarm Current Consumption 0.65 mA @ 24 VDC
SLC Circuit Loading Occupies 1 address; supports up to 252 addressable devices per loop
Visual Annunciation Dual status LEDs providing full 360° visibility (Flashing = Normal, Steady = Alarm)
Remote Output Terminal Fully compatible with Maple Armor FW2561-RI Remote LED Alarm Indicator plate
Compatible Panel Series Maple Armor Series 2 (FW2105 Multi-Loop & FW2107 Releasing Panels)
Compatible Base Models FW2501 (4-inch Standard), FW2502 (6-inch Flanged), FW2509 (Sounder Base)
Field Wiring Terminals 18 AWG to 12 AWG (0.82 mm² to 3.31 mm²) solid or stranded wiring
Dimensions & Weight Diameter: 105 mm (4 in.), Height: 43 mm (1-5/8 in.) | Shipping Weight: ~0.14 kg
Enclosure Construction High-impact, flame-retardant engineered polymer
Operating Environment 32°F to 100°F (0°C to 38°C) continuous, 0% to 93% RH non-condensing (Indoor dry)
Listing & Approvals UL 521 Listed, ULC-S530 Certified, FCC Compliant

⚙️ Engineering & Architectural Resources

Verify thermal spacing matrices, ceiling height reduction factors, and circuit impedance boundaries in compliance with national NFPA 72 Fire Alarm Code Standards before mounting the Maple Armor FW2521 Addressable Heat Detector grid.

📥 Download Official Technical Submittal Sheet (DOC-12521)

Precision Dual-Mode Thermal Detection & Hostile Environment Reliability

The core advantage of the Maple Armor FW2521 Addressable Heat Detector is its high-sensitivity electronic thermistor circuit. Unlike standard mechanical heat sensors that suffer from thermal lag, the internal MCU continuously evaluates real-time temperature fluctuations. If a sudden spike in thermal energy occurs (Rate-of-Rise) or ambient temperature reaches the fixed 135°F (57.2°C) threshold, the detector instantly transmits an alarm condition to the central panel, ensuring rapid early warning before radiant flames cause extensive property loss.

Engineered for high installation versatility, the Maple Armor FW2521 Addressable Heat Detector fits onto the same family of plug-in twist bases used by Series 2 smoke detectors. Addresses are configured prior to installation using an electronic handheld programmer, simplifying maintenance and device swapping. This plug-and-play modularity ensures that facilities with mixed sensing requirements can maintain uniform base wiring throughout the property.

  • Dual-Action Thermal Response: Provides instantaneous rate-of-rise detection during rapid heat surges and a fixed 135°F ceiling threshold for slow-burning fires.
  • Complete 360-Degree Diagnostics: Dual visible LED indicators provide instant identification of normal, trouble, and alarm states from any angle below.
  • Auxiliary Remote Output: Direct wiring terminals support external remote LED indicator plates for ceiling voids and enclosed spaces.
  • Electronic Handheld Addressing: Eliminates mechanical DIP switches and rotary dials, allowing rapid digital addressing and verification.

Frequently Asked Questions (FAQ)

Q1: Does the Maple Armor FW2521 Addressable Heat Detector include a mounting base?
A: No, detector bases are sold separately. You can choose between the FW2501 (4-inch standard base), FW2502 (6-inch flanged base), or FW2509 (sounder base) depending on site wiring and mounting needs.

Q2: Where should the Maple Armor FW2521 Addressable Heat Detector be installed instead of a smoke detector?
A: It is ideal for commercial kitchens, boiler rooms, parking garages, generator rooms, loading docks, and manufacturing plants where steam, exhaust fumes, or dust would cause false alarms on optical smoke detectors.

Q3: How is the address assigned to this heat detector?
A: Device addresses are electronically written into the non-volatile memory of the detector using a Maple Armor handheld programmer before locking the unit into its base.

Q4: Can this detector trigger an external remote lamp?
A: Yes. When connected to compatible bases, the detector provides dedicated terminals to drive the Maple Armor FW2561-RI Remote LED Indicator plate.

Q5: Which fire alarm control panels support the FW2521?
A: The FW2521 is fully compatible with Maple Armor Series 2 control panels, including the FW2105 multi-loop panel and the FW2107 agent releasing panel.

Reviews

There are no reviews yet.

Be the first to review “Maple Armor FW2521 Addressable Heat Detector (Fixed Temperature & Rate-of-Rise)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581