GST DI-M9204 Addressable Manual Call Point (UL Listed)

• Non-Breaking Activation: Re-settable plastic operating plate allows rapid manual alarm triggering without breaking glass
• Safety Certification: Fully listed and certified under UL 38 and NFPA 72 North American standards for manual signaling boxes
• Key-Operated Reset: Supplied with a specialized reset key to restore the unit quickly after emergency activations or routine testing
• Digital Electronic Addressing: Configurable from address 1 to 242 via handheld programmer without mechanical switch wear
• Modular Plug-In Structure: Pre-wireable base and separate plug-in electronic body simplify installation and circuit continuity checks
• Visual Confirmation LED: Front red LED flashes every 3 seconds in standby monitoring and illuminates steady red upon alarm activation
• Durable Enclosure: Built from high-impact, flame-retardant ABS plastic in signal red with an IP43 indoor protection rating

Best Price Guaranteed

Description

The GST DI-M9204 Addressable Manual Call Point is an intelligent, high-reliability emergency initiating device manufactured by GST (Carrier) to provide immediate manual fire alarm reporting.

Engineered with a re-settable, non-breaking operating faceplate, the GST DI-M9204 enables occupants to initiate an alarm instantly by pressing the central action plate during an emergency.

Certified in strict compliance with the American UL 38 standard and NFPA 72 codes, this call point eliminates broken glass hazards, enabling fast reset and routine testing via a dedicated maintenance key.

Technical Specifications Table

Product Model GST DI-M9204 Digital Addressable Manual Call Point
Manufacturer Part Number 30306468 (DI-M9204)
Brand Portfolio GST (Carrier)
Regulatory Standards UL Listed (UL 38 Standard for Manual Signaling Boxes / NFPA 72 Compliant; UL Category Type F 3SZM)
Operating Loop Voltage 24 VDC Nominal (16 VDC to 28 VDC operating range, Power Limited)
Standby Current ≤ 0.6 mA (Quiescent monitoring current)
Alarm Current ≤ 1.8 mA (Active alarm transmission current)
Operating Element Type Reusable, re-settable plastic operating plate (Non-breaking glass)
Reset & Test Mechanism Specialized key-operated reset and maintenance test mechanism
Addressing Method Electronic addressing via P-9910B Handheld Programmer (Address range: 1 to 242)
Visual Alarm Indicator Red LED (Flashes every 3 seconds on polling, illuminates steady red in active alarm)
Wiring Constraints Polarity-insensitive 2-wire signaling line circuit (SLC) connection (Terminals Z1, Z2)
Recommended Cable Gauge 18 AWG to 12 AWG fire-rated twisted cable
Enclosure Material & Color Flame-retardant ABS Plastic | Color: Signal Red
Ingress Protection Rating IP43 (Designed strictly for indoor wall mounting)
Operating Environment -10°C to +50°C (14°F to 122°F), ≤ 95% Relative Humidity non-condensing
Dimensions (With Back Box) 87.1 mm (W) × 87.1 mm (H) × 58.5 mm (D)
Mounting Hole Distance 60 mm standard fixing centres
Unit Weight Approximately 160 g (With surface back box)

⚙️ Engineering & Architecture Resources

Verify manual station mounting heights, egress route accessibility, and signaling loop wiring resistance in accordance with NFPA 72 codes and UL Life Safety Equipment Standards before completing final site commissioning for your GST DI-M9204 emergency initiation stations.

📥 Download Official Technical Submittal Datasheet (30306468)

High-Speed Digital Signaling & Re-settable GST DI-M9204 Architecture

The operational foundation of the GST DI-M9204 relies on advanced digital loop communication.

When an occupant presses the operating plate during a fire emergency, the internal micro-switch triggers instantly, prompting the unit to broadcast its unique programmed address and a high-priority interrupt to the central fire alarm control panel.

This rapid digital protocol ensures that evacuation sequences, audio-visual sounders, and smoke management systems activate without delay.

Traditional manual stations often require replacement glass elements after an activation or routine drill.

The GST DI-M9204 eliminates this ongoing maintenance expense by employing a flexible, re-settable operating plate.

Following an emergency activation or test, authorized personnel insert the provided reset key into the underside keyhole and turn it clockwise to rebound the mechanism back to normal standby status.

Designed for fast field installation, the GST DI-M9204 features a modular three-piece assembly: back box, base, and plug-in MCP body.

Contractors can pre-wire the terminal base and verify circuit continuity using the included test tool before snapping the electronic module into place.

Addressing is configured electronically from 1 to 242 using the GST P-9910B handheld programmer, removing the risk of mechanical switch corrosion on site.

  • UL 38 Listed Performance: High-reliability manual emergency pull station built to North American life-safety fire standards.
  • Re-settable Operating Element: Eliminates broken glass replacements, reducing maintenance costs and avoiding injury risks.
  • Electronic Address Configuration: Simple digital programming from 1 to 242 via handheld programming tools.
  • Modular Plug-In Base: Enables pre-wiring and loop continuity testing prior to installing the sensitive electronics body.

Frequently Asked Questions (FAQ)

Q1: Does the GST DI-M9204 require glass replacement after an alarm activation?
A: No. The GST DI-M9204 utilizes a reusable, re-settable plastic operating plate. After activation, the device is restored to normal operation using the specialized reset key included in the box.

Q2: What certifications does the GST DI-M9204 manual call point hold?
A: The GST DI-M9204 is UL Listed under UL 38 (Standard for Manual Signaling Boxes for Fire Alarm Systems) and complies fully with NFPA 72 installation requirements.

Q3: How is the loop address programmed on the GST DI-M9204?
A: The loop address (from 1 to 242) is programmed electronically using the GST P-9910B handheld programmer, eliminating physical rotary dials and DIP switches.

Q4: What is the purpose of the test tool included with the GST DI-M9204?
A: The test tool maintains signaling loop circuit continuity across the terminal base during rough-in construction before the active call point body is plugged in.

Q5: What are the wiring connection requirements for the GST DI-M9204?
A: The call point connects directly to the 2-wire SLC loop across Terminals Z1 and Z2 using polarity-insensitive fire-rated cable (18 AWG to 12 AWG).

Q6: Is the GST DI-M9204 suitable for outdoor installation?
A: The GST DI-M9204 carries an IP43 ingress protection rating and is designed strictly for indoor corridors, exit doors, and stairwells. For outdoor or wet areas, a weatherproof protective cover is required.

Reviews

There are no reviews yet.

Be the first to review “GST DI-M9204 Addressable Manual Call Point (UL Listed)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581