GST DI-M9102N Addressable Multi-Criteria Smoke Detector with DB-M01N Base (UL Listed)

• Advanced MWMA Optical Sensing: Utilizes Multi-Wave Multi-Angle light-scattering technology to distinguish real smoke from dust and steam
• UL 268 7th Edition Certified: Fully listed and approved under UL 268 standards to prevent cooking-related nuisance alarms
• 3-Level Programmable Sensitivity: Field-selectable obscuration settings (Level 1: 1.38%–3.38%/ft, Level 2: 2.25%–4.25%/ft, Level 3: 3.12%–5.12%/ft)
• Continuous Drift Compensation: Auto-adjusts baseline reference levels against environmental dust accumulation to ensure long-term stability
• Dual LED Diagnostics: Red omnidirectional alarm LED (360° view) and a dedicated steady yellow fault LED for local troubleshooting
• Remote Output Support: Dedicated polarized terminals to drive an external remote indicator lamp (e.g., GST C-9314P)
• Matching Base Included: Supplied complete with the GST DB-M01N flame-retardant ceiling base for non-polarized 2-wire SLC loops

Best Price Guaranteed

Description

The GST DI-M9102N Addressable Multi-Criteria Smoke Detector with DB-M01N Base is an intelligent optical life-safety sensor engineered by GST (Carrier) to provide rapid early warning fire detection.

Utilizing patented Multi-Wave Multi-Angle (MWMA) light-scattering technology, the GST DI-M9102N analyzes smoke particles across multiple optical wavelengths and refraction angles.

Certified in strict compliance with the rigorous UL 268 7th Edition standard, the detector prevents cooking-related nuisance alarms while delivering high detection sensitivity across commercial, institutional, and hospitality facilities.

Technical Specifications Table

Product Model GST DI-M9102N Intelligent Multi-Criteria Smoke Detector
Mounting Base Model GST DB-M01N Flame-Retardant Common Base (Included)
Brand Portfolio GST (Carrier)
Regulatory Standards UL Listed (UL 268 7th Edition / NFPA 72 Compliant; UL Fire Alarm Subassembly)
Operating Loop Voltage 24 VDC Nominal (16 VDC to 28 VDC operating range, Power Limited)
Standby Current ≤ 0.4 mA (Quiescent monitoring current)
Alarm Current ≤ 1.4 mA (Without remote indicator) / ≤ 3.4 mA (With remote indicator active)
Detection Principle Multi-Wave Multi-Angle (MWMA) Photoelectric Light Scattering
Programmable Sensitivity Levels Level 1: 1.38%–3.38%/ft | Level 2: 2.25%–4.25%/ft | Level 3: 3.12%–5.12%/ft
Addressing Method Electronic addressing via P-9910B Handheld Programmer (Address range: 1 to 242)
Fire Alarm Indicator Red omnidirectional LED (360° view; flashes on polling, illuminates steady in alarm)
Fault Diagnostic Indicator Yellow LED (Illuminates steadily in chamber fault or drift limit condition)
Remote Output Support Polarized 2-wire output for remote indicator connection (e.g., GST C-9314P)
Wiring Constraints Non-polarized 2-core cable for SLC loop (Terminals 1 & 3); Polarized for remote LED (Terminals 2 & 4)
Enclosure Material & Color Flame-retardant ABS Plastic | Color: White (RAL 9016)
Ingress Protection Rating IP2X (Certified strictly for indoor ceiling mounting)
UL Operating Temperature 0°C to +49°C (32°F to 120°F), ≤ 95% Relative Humidity non-condensing
Extended Operating Temperature -10°C to +55°C (14°F to 131°F), ≤ 95% Relative Humidity non-condensing
Physical Dimensions Diameter: 100 mm × Height: 54.5 mm (Assembled with DB-M01N Base)
Unit Weight Approximately 110 g

⚙️ Engineering & Architecture Resources

Verify optical detector spacing, air handling unit velocities, and signaling line circuit wire gauges in accordance with NFPA 72 codes and UL Life Safety Equipment Standards before completing final site commissioning for your GST DI-M9102N detection network.

📥 Download Official Technical Submittal Datasheet (DS10106112)

Multi-Wave Multi-Angle Sensing & UL 268 7th Edition GST DI-M9102N Reliability

The operational foundation of the GST DI-M9102N utilizes multi-spectral optical evaluation to analyze airborne particles inside its sensing chamber.

Traditional single-wavelength smoke sensors often struggle to differentiate between genuine combustion smoke and transient environmental interference such as kitchen steam, aerosols, and fine construction dust.

By assessing particle geometry with Multi-Wave Multi-Angle (MWMA) algorithms, the GST DI-M9102N recognizes true combustion signatures instantly while rejecting common false-alarm sources.

Long-term field reliability is preserved through automated baseline drift compensation.

As dust particles settle inside the optical maze over months of service, the internal microprocessor continuously adjusts its baseline measurement threshold.

This automated compensation ensures that the exact smoke density required to trigger an alarm remains constant, eliminating nuisance alarms while preserving life-safety sensitivity.

Device installation and system setup are streamlined through electronic address programming.

Using the GST P-9910B handheld programmer, field technicians configure loop addresses from 1 to 242 and choose between 3 sensitivity levels electronically.

The detector includes a built-in magnetic reed switch, allowing maintenance teams to perform quick functional alarm tests using a magnetic commissioning tool without test gas canisters.

  • UL 268 7th Edition Listed: Advanced particle discrimination algorithms prevent unwanted cooking and steam alarms.
  • Intelligent Baseline Drift Compensation: Auto-recalibrates sensitivity thresholds against dust accumulation over time.
  • Electronic Address Programming: Easily configured from address 1 to 242 via handheld programming tools without rotary switches.
  • Dual LED Visual Confirmation: 360-degree red alarm LED for fire signaling and a steady yellow LED for fault indication.

Frequently Asked Questions (FAQ)

Q1: What is the main advantage of Multi-Wave Multi-Angle (MWMA) technology on the GST DI-M9102N?
A: MWMA technology uses multiple light wavelengths and scatter angles to identify specific smoke particle characteristics, allowing the detector to pass UL 268 7th Edition tests and avoid false alarms from cooking smoke or steam.

Q2: Does this product listing include the detector base?
A: Yes. This package includes both the GST DI-M9102N addressable photoelectric smoke detector head and the matching GST DB-M01N flame-retardant mounting base.

Q3: How is the loop address set on the GST DI-M9102N detector?
A: The loop address (from 1 to 242) and smoke sensitivity levels (Levels 1 to 3) are programmed electronically using the GST P-9910B handheld programmer.

Q4: Can the flashing polling LED on the GST DI-M9102N be disabled?
A: Yes. In environments such as hotel guest rooms or residential quarters where blinking lights are undesirable, the polling LED can be turned off via programmer parameters while maintaining full steady red illumination during an alarm.

Q5: What are the loop wiring and remote indicator connections on the DB-M01N base?
A: Connect the 2-wire SLC loop across Terminals 1 and 3 (non-polarized). Terminals 2 (positive) and 4 (negative) provide a dedicated polarized drive circuit for an external remote indicator lamp (such as the GST C-9314P).

Q6: How can technicians perform local testing on the GST DI-M9102N without smoke canisters?
A: The detector contains a built-in magnetic reed switch. Placing a magnetic commissioning wand near the marked test zone activates an internal test alarm to confirm loop communication and control panel signaling.

Reviews

There are no reviews yet.

Be the first to review “GST DI-M9102N Addressable Multi-Criteria Smoke Detector with DB-M01N Base (UL Listed)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581