Gala / System Sensor 100mm (4″) UL/FM Water Flow Switch for Fire Sprinklers

                                                                      • Primary Purpose: Detects sustained water flow in 100 mm (4-inch) fire sprinkler pipes and transmits an immediate alarm signal to the Fire Alarm Control Panel (FACP).

                                                                      • Key Specifications: 100 mm (4-inch) pipe size, UL Listed & FM Approved, dual SPDT micro-switches, and adjustable pneumatic retard delay (0–90 seconds).

                                                                      • Customer Benefits: Eliminates false alarms caused by water pressure surges while ensuring rapid zone-specific fire detection and life safety compliance.

                                                                      • Bangladesh Market Relevance: Essential for RMG textile factories, pharmaceutical plants, warehouses, and commercial high-rises across Bangladesh requiring strict NFPA 13, BNBC, and international audit compliance.

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-2-1-1-1 Category Tags: , , , ,

Description

Product Overview

What is this product? The Gala / System Sensor 100 mm (4″) UL/FM Water Flow Switch is a vane-type electromechanical supervisory device installed directly onto 4-inch (DN100) wet-pipe fire sprinkler mains or branch lines.

How does it work? A flexible, non-corrosive paddle (vane) sits inside the 100 mm steel sprinkler pipe. When a sprinkler head activates due to heat or fire, water rushes through the pipe and deflects the paddle. This movement triggers an adjustable pneumatic retard mechanism that delays switching briefly to ignore harmless pressure spikes, then actuates two synchronized SPDT (Form-C) micro-switches to alert the building’s Fire Alarm Control Panel and local notification appliances.

Who needs this product? MEP contractors, fire detection and protection engineers, facility maintenance teams, and industrial project developers building or upgrading automated sprinkler systems.

Why is it useful in Bangladesh? Industrial factories, garment manufacturing units, commercial towers, and logistics warehouses in Dhaka, Gazipur, Chattogram, and Narayanganj must maintain certified fire alarm and sprinkler integration to meet BNBC, NFPA 13, and international buyer safety audits. Using UL Listed and FM Approved Gala or System Sensor flow switches guarantees dependable alarm signaling under local water pressure fluctuations.

Key Features

  • UL Listed & FM Approved: Certified to international fire protection standards for wet-pipe automatic sprinkler systems.

  • Adjustable Pneumatic Retard (0–90 Seconds): Prevents false alarms triggered by transient water surges or municipal pressure fluctuations.

  • Dual Synchronized SPDT Switches: Two Form-C dry-contact switches allow simultaneous signaling to the Fire Alarm Control Panel and auxiliary annunciators or BMS.

  • Rugged NEMA 4 / IP54 Enclosure: Die-cast metal housing with gasketed cover protects internal contacts from dust, moisture, and splash exposure.

  • Tamper-Resistant Cover Screws: Requires a specialized key/wrench to open, preventing unauthorized tampering in industrial pump rooms and risers.

  • Easy U-Bolt Saddle Mounting: Installs cleanly onto Schedule 10 through Schedule 40 100 mm (4″) steel pipe via a single drilled hole.

Technical Advantages

  • False-Alarm Immunity: Mechanical pneumatic time-delay chamber filters out brief water hammer effects without requiring external power.

  • Corrosion-Resistant Vane Assembly: Durable polymer/composite paddle resists mineral buildup, rust, and fatigue in stagnant sprinkler water.

  • High Electrical Contact Reliability: Snap-action SPDT switches provide clean, chatter-free alarm and supervisory zone reporting.

  • Simplified Wiring & Maintenance: Generous wiring terminal block with dual conduit knockouts speeds up field installation and periodic inspector testing.

Applications

  • Industrial & RMG Factories: Floor-by-floor and zone-by-zone sprinkler riser monitoring in textile, spinning, and garment facilities.

  • Commercial High-Rises: Office buildings, shopping malls, hotels, and hospitals with multi-zone wet sprinkler networks.

  • Warehouses & Cold Storage: High-bay storage facilities requiring accurate zone identification upon sprinkler activation.

  • Project Installations: New NFPA 13 / BNBC sprinkler installations, fire alarm integration retrofits, and factory audit compliance upgrades.

Why Choose This Product?

  • Dual-Brand Trusted Quality: Both System Sensor and Gala deliver globally proven performance in commercial and industrial fire detection systems.

  • Full Audit & Code Acceptance: UL and FM certifications ensure smooth sign-off from fire safety consultants, insurers, and regulatory inspectors.

  • Long-Term Operational Stability: Built to endure high ambient heat and humidity inside riser shafts and fire pump rooms.

  • Dependable Local Supply: Available in Bangladesh through loopshop.com.bd with technical sizing support and fast nationwide dispatch.

4. Technical Specification Table

Specification Details
Model 100 mm / 4″ Vane-Type Water Flow Switch (WFD40 / GFS-100 Series)
Brand Gala / System Sensor
Pipe Size Compatibility 100 mm (4 Inch / DN100) Steel Pipe (Schedule 10 to 40)
Certifications UL Listed, FM Approved
Switch Configuration Dual SPDT (Two Form-C Dry Contacts)
Retard / Time Delay Adjustable Pneumatic Delay (0 to 90 Seconds)
Enclosure Rating NEMA 4 / IP54 Dust & Water Resistant
Mounting Method U-Bolt Saddle Clamp on Drilled Pipe Hole
System Compatibility Wet-Pipe Fire Sprinkler Systems
Electrical Connection Screw Terminals with Dual Conduit Knockouts

5. Features List

  • ✓ UL Listed and FM Approved for wet sprinkler systems

  • ✓ Fits standard 100 mm (4″) Schedule 10–40 steel sprinkler pipes

  • ✓ Adjustable 0–90 second pneumatic retard to stop false alarms

  • ✓ Dual SPDT (Form-C) switches for FACP and auxiliary monitoring

  • ✓ Weather-resistant NEMA 4 / IP54 die-cast enclosure

  • ✓ Tamper-resistant cover hardware for enhanced system security

  • ✓ Quick U-bolt saddle installation with flexible non-corrosive vane

6. Benefits For Customers

  • Eliminates Costly False Alarms: Built-in pneumatic delay absorbs pressure surges, preventing unnecessary factory evacuations and production stops.

  • Pinpoints Fire Locations Fast: Identifies the exact floor or sprinkler zone where water is flowing, accelerating emergency response.

  • Passes Safety Audits Effortlessly: UL/FM certification satisfies strict international buyer, insurance, and BNBC fire safety requirements in Bangladesh.

  • Low Maintenance Durability: Corrosion-resistant paddle and sealed housing ensure years of trouble-free service in humid environments.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the switch on a straight section of 100 mm (4″) horizontal or vertical pipe at least 150 mm (6″) away from fittings, valves, or elbows that cause turbulence.

  • Drill the manufacturer-specified hole size cleanly into the pipe wall and deburr all internal metal edges so the paddle moves freely without snagging.

  • Align the directional flow arrow on the switch housing with the actual direction of water flow, and tighten the U-bolt nuts evenly.

Maintenance Tips:

  • Test flow switch operation quarterly or semi-annually by opening the Inspector’s Test Connection at the end of the sprinkler branch line.

  • Verify that the alarm activates within 90 seconds of sustained flow and resets automatically once the test valve is closed.

  • Inspect the enclosure gasket and conduit seals periodically to keep moisture and dust out of the switch compartment.

Safety Instructions:

  • Drain and depressurize the sprinkler zone completely before drilling the pipe or removing the water flow switch.

  • Disconnect low-voltage fire alarm signaling circuits or place the Fire Alarm Control Panel in test/bypass mode prior to servicing to avoid unintended building alarms.

8. FAQ Section

Q: What is the price of Water Flow Switch 100 mm (4″) in Bangladesh? A: The price of a UL/FM 100 mm (4″) Water Flow Switch (Gala / System Sensor) in Bangladesh depends on brand selection and order volume. Visit loopshop.com.bd or contact our team for current BDT pricing and project quotes.

Q: Where can I buy Gala or System Sensor 4″ Water Flow Switch in Bangladesh? A: You can order genuine UL/FM water flow switches directly online from loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, and all over Bangladesh.

Q: What warranty does this product have? A: It includes a standard manufacturer warranty against defects, backed by local technical support from Loop Shop Bangladesh.

Q: Is this suitable for the Bangladesh climate? A: Yes. Featuring a sealed NEMA 4 / IP54 enclosure and corrosion-resistant internal paddle, it performs reliably in Bangladesh’s high-humidity and warm industrial environments.

Q: How to install this product? A: Drill the specified mounting hole in the 100 mm (4″) sprinkler pipe, insert the folded vane carefully, align the flow direction arrow, and secure the saddle clamp with the supplied U-bolt.

Q: Why does a water flow switch have a time delay (retard)? A: The adjustable 0–90 second pneumatic retard prevents momentary water pressure surges or pump start-up spikes from triggering false fire alarms.

Q: Can this water flow switch connect to any Fire Alarm Control Panel (FACP)? A: Yes. Its dual SPDT dry-contact switches interface seamlessly with conventional and addressable monitor modules from any standard FACP brand.

Q: What is the difference between UL Listed and FM Approved? A: Both are top-tier independent safety certifications; having dual UL/FM approval guarantees acceptance across virtually all global engineering codes, insurers, and factory compliance audits.

Q: Can this switch be mounted vertically as well as horizontally? A: Yes, it can be mounted on horizontal pipes or vertical risers with upward water flow, provided it is positioned away from elbows and valves.

Q: Is this switch suitable for dry-pipe or deluge sprinkler systems? A: No. Vane-type water flow switches are designed specifically for wet-pipe sprinkler systems; dry-pipe systems require pressure-type alarm switches.

Reviews

There are no reviews yet.

Be the first to review “Gala / System Sensor 100mm (4″) UL/FM Water Flow Switch for Fire Sprinklers”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?