Description
Product Overview
What is this product? The Fiffco 65 mm (2-1/2″) Flexible Rubber Expansion Joint (Non-Listed) is a heavy-duty, flanged elastomer pipe connector designed to isolate vibration and compensate for axial, lateral, and angular pipeline movements.
How does it work?Installed directly on the suction and discharge sides of pumps, chillers, and compressors, the flexible molded rubber sphere compresses, extends, or deflects laterally to absorb equipment vibration, pressure surges, and thermal expansion before those stresses transfer into rigid steel or GI piping.
Who needs this product? MEP contractors, HVAC engineers, plumbing installers, factory maintenance teams, and industrial plant operators managing pressurized water or utility piping systems.
Why is it useful in Bangladesh? Industrial factories, RMG facilities, commercial high-rises, and water treatment plants across Bangladesh experience frequent pump start/stop cycles and seasonal ambient temperature fluctuations. Installing a 65 mm flexible rubber expansion joint prevents pipe joint cracking, reduces pump room noise transmission, and corrects minor flange alignment tolerances during installation.
Key Features
-
High-Elasticity Molded Bellows: Precision-molded and vulcanized elastomer body engineered for superior vibration damping and acoustic isolation.
-
Multi-Layer Cord Reinforcement: Reinforced with high-tensile synthetic nylon/polyester fabric plies and solid carbon steel internal reinforcing rings for pressure stability.
-
Floating Metal Flanges: Free-rotating galvanized/mild steel flanges allow effortless bolt-hole alignment without twisting the rubber bellows.
-
Multi-Directional Movement Absorption: Compensates simultaneously for axial compression, axial elongation, lateral deflection, and angular misalignment.
-
No Additional Gaskets Required: Integrated raised rubber sealing faces form a tight, leak-free seal directly against mating pipe flanges.
-
Non-Listed Commercial/Industrial Grade: Cost-effective solution for HVAC, plumbing, water supply, and non-UL/FM utility lines.
Technical Advantages
-
Vibration & Noise Attenuation: Isolates structure-borne mechanical vibration from centrifugal pumps and chillers, reducing noise across building floors.
-
Thermal & Surge Protection: Absorbs thermal pipe expansion and dampens hydraulic water hammer shock during pump startup and shutdown.
-
Durable Construction: Resistant to aging, ozone, and standard water treatment chemicals for dependable long-term service.
-
Easy Maintenance & Replacement: Floating flange design simplifies bolt installation and reduces downtime during routine piping inspection.
Applications
-
HVAC & Chiller Plants: Chilled water and condenser water pump suction/discharge headers.
-
Industrial & Factory Utilities: Cooling tower lines, process water circulation, and utility pump skids.
-
Commercial & Residential Buildings: Booster pump sets, transfer pumps, and domestic water supply risers.
-
Water & Wastewater Treatment: Filtration units, RO plants, and non-listed fire/utility water networks.
Why Choose This Product?
-
Proven Pump Protection: Prevents stress transfer onto sensitive pump nozzles and mechanical seals.
-
Installer-Friendly Design: Accommodates minor piping installation offsets while eliminating the need for separate flange gaskets.
-
Cost-Effective Performance: Delivers reliable pressure handling and vibration control for non-listed piping applications without the premium cost of UL/FM listed joints.
-
Trusted Supply in Bangladesh: Available through loopshop.com.bd with technical sizing support and fast delivery for ongoing MEP projects.
4. Technical Specification Table
| Specification | Details |
| Model | 65 mm (2-1/2″) Flexible Rubber Expansion Joint (Non-Listed) |
| Brand | Fiffco (or Equivalent) |
| Nominal Pipe Size | 65 mm / 2-1/2 Inch (DN65) |
| Certification Status | Non-Listed |
| Bellows Material | Molded Synthetic Rubber (EPDM / Neoprene Compound) |
| Reinforcement | High-Tensile Synthetic Fabric Cord & Solid Steel Wire Ring |
| Flange Material | Carbon / Mild Steel (Zinc-Plated / Anti-Corrosion Coated) |
| Flange Standard | Multi-Standard Drilled (PN16 / ANSI Class 150 Compatible) |
| Connection Type | Flanged (Floating Flanges) |
| Suitable Media | Cold Water, Warm Water, Neutral Liquids, HVAC Water |
5. Features List
-
✓ 65 mm (2-1/2″) nominal diameter for standard pump and header connections
-
✓ Absorbs pump vibration, noise, and hydraulic surge shock
-
✓ Compensates for axial, lateral, and angular pipe movements
-
✓ Multi-ply synthetic cord reinforcement with solid steel bead rings
-
✓ Floating steel flanges for fast, twist-free bolt alignment
-
✓ Self-sealing rubber flange faces (no extra gaskets needed)
-
✓ Non-Listed grade ideal for HVAC, plumbing, and general industrial piping
6. Benefits For Customers
-
Extends Pump & Piping Lifespan: Eliminates mechanical strain on pump casings, bearings, and rigid pipe welds caused by continuous vibration.
-
Quieter Building Operation: Stops pump vibration from traveling through steel pipes into office floors, hotels, and hospital rooms.
-
Faster Project Installation: Floating flanges compensate for slight bolt-hole misalignments on site, saving contractor labor hours.
-
Suited for Bangladesh Conditions: Built to withstand high pump-room humidity, continuous industrial duty cycles, and local water conditions.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install the expansion joint in its neutral face-to-face length; never stretch, compress, or twist the rubber bellows to bridge oversized pipe gaps.
-
Ensure adjacent pipelines are properly anchored and guided on both sides so hydraulic thrust forces do not over-extend the joint.
-
Tighten flange bolts evenly in a star/crisscross sequence until the rubber flange bead sits snugly against the mating flange without over-crushing.
Maintenance Tips:
-
Inspect the outer rubber surface periodically for signs of cracking, blistering, hardening, or chemical attack.
-
Re-check flange bolt tightness after the first few weeks of system pressurization and thermal cycling.
-
Keep the rubber bellows free from paint, oil, grease, and direct UV exposure.
Safety Instructions:
-
Never weld near an installed rubber expansion joint without covering it with a wet fireproof blanket to prevent heat or weld-spatter damage.
-
Always depressurize and drain the pipeline completely before loosening flange bolts or removing the joint.
-
Do not install this Non-Listed joint on fire protection systems where UL Listed or FM Approved components are mandated by code.
8. FAQ Section
Q: What is the price of Fiffco 65 mm (2-1/2″) Flexible Rubber Expansion Joint in Bangladesh? A: The price of a 65 mm (2-1/2″) Non-Listed Flexible Rubber Expansion Joint in Bangladesh depends on flange rating and order quantity. Visit loopshop.com.bd or request a quote for current BDT wholesale and project rates.
Q: Where can I buy 65 mm Flexible Rubber Expansion Joint in Bangladesh? A: You can order online directly from loopshop.com.bd or contact Loop Engineering for supply across Dhaka, Gazipur, Chattogram, Narayanganj, and industrial zones nationwide.
Q: What warranty does this product have? A: It carries a standard warranty against manufacturing defects provided through Loop Shop. Contact our team with your project specifications for exact coverage terms.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its weather-resistant synthetic elastomer body and coated steel flanges perform reliably in humid, high-ambient-temperature mechanical and pump rooms across Bangladesh.
Q: How to install this product? A: Position the joint between two properly anchored 65 mm pipe flanges in its neutral length, align the floating flanges, insert bolts from the bellows side outward (so bolt threads do not puncture the rubber), and tighten evenly in a crisscross pattern.
Q: What does “Non-Listed” mean for this expansion joint?A: “Non-Listed” means the joint is manufactured to standard industrial pressure and dimensional norms (such as PN16 / ANSI 150) rather than carrying UL/FM fire protection certification, making it ideal for HVAC, plumbing, water supply, and non-listed utility systems.
Q: Do I need separate flange gaskets when installing this rubber expansion joint? A: No. The molded rubber ends wrap over the flange faces and act as built-in, self-sealing gaskets against flat-face or raised-face companion flanges.
Q: Can this 65 mm joint be installed on both pump suction and discharge lines?A: Yes, it is suitable for both suction and discharge connections on centrifugal pumps within its rated working pressure and vacuum limits.
Q: Should I use control rods (tie bars) with this expansion joint?A: If the pipeline is not rigidly anchored to resist pressure thrust—especially on discharge lines exceeding 10 bar—control rods are recommended to prevent over-extension.
Q: Is this compatible with PN16 and ANSI Class 150 flanges? A: Yes, standard 65 mm (2-1/2″) floating flanges are drilled to match common PN16 / ANSI Class 150 bolt patterns used in Bangladesh MEP projects

Reviews