Description
Product Overview
What is this product? The 2″ (50 mm) Zone Control Valve Set (also known as a Floor Control Valve Assembly) is a pre-engineered, integrated fire sprinkler riser manifold assembly. It combines a supervised shutoff valve, a check valve, a vane-type waterflow detector switch, a pressure gauge, and an inspector’s test and drain valve into a single compact unit.
How does it work? Installed at the branch connection feeding a specific floor or fire zone, the isolation valve remains locked open and electronically supervised via tamper switches. Under normal conditions, the check valve prevents reverse water flow into the main riser, while the pressure gauge displays static system pressure. When a sprinkler head activates due to heat, water flows through the 2″ assembly, deflecting the waterflow switch paddle to send an immediate alarm signal to the Fire Alarm Control Panel (FACP).
Who needs this product? Fire protection contractors, MEP engineers, factory compliance teams, and commercial building developers designing or upgrading wet-pipe automatic sprinkler systems.
Why is it useful in Bangladesh? Multi-story garment factories (RMG), textile mills, commercial towers, and shopping malls in Dhaka, Gazipur, Chattogram, and Narayanganj require zoned fire sprinkler monitoring under NFPA 13, BNBC, and international buyer safety audits (RSC/Accord/Nirapon). Using a complete 2″ Zone Control Valve Set reduces on-site fabrication errors, speeds up installation, and ensures smooth inspection sign-off.
Key Features
-
All-in-One Integrated Assembly: Combines isolation control, backflow prevention, waterflow alarm detection, pressure monitoring, and test/drain functions in one compact 2″ (50 mm) manifold.
-
Supervised Isolation Valve: Equipped with built-in supervisory tamper switches to alert the fire alarm panel immediately if the valve is partially or fully closed.
-
Sensitive Vane-Type Waterflow Switch: Features a pneumatic retard mechanism to prevent false alarms caused by water pressure surges while ensuring rapid fire detection.
-
Integrated Non-Return Check Valve: Prevents reverse flow and pressure loss back into the main sprinkler riser during pressure fluctuations.
-
High-Visibility Pressure Gauge: Dial pressure gauge (PSI/Bar) allows instant visual verification of zone water pressure during daily safety walk-throughs.
-
Built-In Test & Drain Assembly: Allows periodic testing of the waterflow alarm switch and fast zone draining during sprinkler head replacement without shutting down the entire building.
Technical Advantages
-
Space-Saving Modular Design: Eliminates bulky, multi-joint field-assembled manifolds, fitting neatly inside narrow riser shafts and ceiling voids.
-
Reduced Leak Points: Factory-matched threaded/grooved interfaces minimize joint connections and installation labor time on site.
-
Reliable Alarm Integration: Standard SPDT dry contacts on both the tamper switch and waterflow detector interface seamlessly with addressable or conventional FACPs.
-
Corrosion-Resistant Finish: Heavy-duty ductile iron/brass wetted components with fusion-bonded red epoxy coating withstand humid pump and riser room conditions.
Applications
-
RMG & Textile Factories: Floor-by-floor sprinkler zone control in sewing, cutting, finishing, and fabric storage floors.
-
Commercial High-Rises: Office towers, shopping malls, hotels, and residential apartments requiring isolated floor-level fire protection.
-
Healthcare & Institutions: Hospitals, universities, and pharmaceutical facilities where localized maintenance cannot disrupt building-wide fire protection.
-
Warehouses & Logistics: Zoned storage racks and cold/dry storage bays protected by wet-pipe sprinkler networks.
Why Choose This Product?
-
Complete Compliance Solution: Engineered specifically to satisfy NFPA 13 floor control assembly requirements for wet-pipe sprinkler systems.
-
Faster Project Commissioning: Arrives ready for direct installation into 2″ (50 mm) schedule 40/10 steel sprinkler branch lines.
-
Easy Maintenance & Testing: Integrated sight glass and test/drain valve simplify mandatory weekly and quarterly fire safety drills.
-
Local Engineering Support: Supplied in Bangladesh by Loop Engineering & Loop Shop with full technical documentation and fire alarm integration guidance.
4. Technical Specification Table
| Specification | Details |
| Product Name | Zone Control Valve Set (Floor Control Assembly) |
| Nominal Size | 2 Inch (50 mm) |
| Connection Type | Grooved / NPT Threaded Ends |
| Working Pressure Rating | 175 PSI / 300 PSI (12 Bar / 20.7 Bar) |
| Included Components | Supervised Shutoff Valve, Check Valve, Vane Waterflow Switch, Pressure Gauge, Test & Drain Valve with Sight Glass |
| Body Material | Ductile Iron (Red Epoxy Coated) / Brass Trim |
| Electrical Switch Contacts | Dual SPDT Tamper & Waterflow Alarm Contacts |
| Waterflow Retard Time | Adjustable Pneumatic Delay (0–90 Seconds) |
| Pressure Gauge Range | 0–300 PSI (0–20 Bar) Dual Scale |
| Application System | Wet-Pipe Automatic Fire Sprinkler Systems |
5. Features List
-
✓ Complete 2″ (50 mm) pre-assembled fire sprinkler zone control manifold
-
✓ Supervised isolation valve with tamper switch for FACP monitoring
-
✓ Vane-type waterflow switch with adjustable retard to prevent false alarms
-
✓ Integrated check valve preventing backflow into the main riser
-
✓ Dual-scale (PSI/Bar) pressure gauge for instant visual pressure checks
-
✓ Built-in inspector’s test & drain valve with sight glass
-
✓ Heavy-duty red corrosion-resistant epoxy finish for long service life
6. Benefits For Customers
-
Minimizes Downtime During Repairs: Enables maintenance teams to isolate and drain a single 2″ floor zone without shutting off fire protection for the rest of the building.
-
Instant Zone Fire Identification: Pinpoints the exact floor or zone where water is flowing on the Fire Alarm Control Panel, speeding up emergency response.
-
Audit & Code Readiness: Meets NFPA 13 and BNBC standards required by Bangladesh Fire Service & Civil Defence (FSCD) and industrial safety inspectors.
-
Lower Installation Cost: Saves significant pipe-fitting labor and reduces potential leak points compared to assembling individual valves on site.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install the 2″ (50 mm) assembly horizontally or vertically in accordance with the directional flow arrows cast on the check valve and waterflow switch body.
-
Ensure the waterflow switch is mounted at least 6 inches away from fittings or changes in direction that could cause water turbulence.
-
Route the test and drain outlet to an adequately sized open drain line capable of handling full 2″ test discharge flow.
-
Connect the tamper switch and waterflow switch wiring to supervised monitor modules on the Fire Alarm Control Panel.
Maintenance Tips:
-
Inspect the pressure gauge weekly to confirm normal system pressure and verify that the isolation valve handle/handwheel is in the fully open position.
-
Conduct quarterly waterflow alarm tests using the built-in test valve to verify timely signal transmission to the FACP without opening a live sprinkler head.
-
Check the sight glass during testing to confirm clear flow and verify that the drain valve reseats completely without dripping afterward.
Safety Instructions:
-
Always notify the building safety officer, security desk, and fire alarm monitoring team before operating the test valve or closing the zone isolation valve.
-
Place a clearly visible impairment tag on the valve whenever it is closed for maintenance, and restore it to the fully open, supervised position immediately upon completion.
8. FAQ Section
Q: What is the price of a 2″ (50 mm) Zone Control Valve Set in Bangladesh? A: The price of the 2″ (50 mm) Zone Control Valve Set with Flow Switch, Check Valve & Gauge depends on brand certification (UL/FM) and project order quantity. Visit loopshop.com.bd or contact our engineering sales team for an exact BDT quote.
Q: Where can I buy a 2″ Zone Control Valve Set in Bangladesh? A: You can order genuine 2″ (50 mm) Fire Sprinkler Zone Control Valve Sets online from loopshop.com.bd or through Loop Engineering, with fast delivery to Dhaka, Gazipur, Chattogram, Narayanganj, and industrial zones nationwide.
Q: What warranty does this product have? A: This assembly includes a manufacturer defect warranty backed by Loop Shop. Contact our team with your project specifications for full warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. The corrosion-resistant epoxy-coated ductile iron body, brass trim, and sealed NEMA-rated electrical switch housings are designed to operate reliably in Bangladesh’s high-humidity environments.
Q: How to install this product? A: Connect the 2″ (50 mm) assembly inline at the sprinkler zone branch connection following the flow arrows, pipe the drain outlet to an open drain, and wire the tamper and flow switches to the fire alarm monitor modules.
Q: What components are included in this Zone Control Valve Set? A: The complete set includes a 2″ supervised isolation valve (with tamper switch), a 2″ non-return check valve, a vane-type waterflow detector switch, a pressure gauge, and an inspector’s test and drain valve.
Q: Can this 2″ Zone Control Valve Set connect to any Fire Alarm Control Panel (FACP)? A: Yes. Both the valve tamper switch and waterflow switch feature standard dry SPDT contacts compatible with all addressable and conventional fire alarm panels.
Q: Why is a retard mechanism included on the waterflow switch? A: The adjustable pneumatic retard (0–90 seconds) prevents false fire alarms triggered by temporary water pressure surges or air pockets in the municipal or pump supply line.
Q: Does this assembly allow testing without activating a sprinkler head? A: Yes. The integrated test and drain valve simulates the flow of a single sprinkler orifice, allowing technicians to test the waterflow switch and alarm system safely.
Q: What size buildings or zones is a 2″ (50 mm) Zone Control Valve Set suitable for? A: A 2″ (50 mm) assembly is typically used for small-to-medium sprinkler zones, commercial office floors, corridors, mezzanines, and residential or hospital wings as calculated by your hydraulic design.

Reviews