Description
Product Overview
What is this product? The 0–300 PSI Fire Pump & Hydrant Pressure Gauge is a heavy-duty, Bourdon tube mechanical pressure instrument engineered specifically for fire protection water systems, including centrifugal fire pump discharge manifolds, standpipe risers, and outdoor hydrant loops.
How does it work? System water enters the gauge’s bottom NPT socket and flows into an internal curved copper-alloy Bourdon tube. As water pressure increases between 0 and 300 PSI, the tube straightens proportionally, driving a precision geared movement that rotates the pointer across a high-contrast dual-scale dial for instant visual reading.
Who needs this product? MEP contractors, fire protection engineers, factory maintenance managers, and facility safety officers equipping new fire pump skids or replacing damaged, foggy, or out-of-calibration gauges on existing sprinkler and hydrant systems.
Why is it useful in Bangladesh? Industrial plants, RMG garment factories, pharmaceutical units, and commercial complexes in Bangladesh undergo rigorous fire safety audits (NFPA 20, NFPA 13, NFPA 14, BNBC, and RSC/Accord-aligned inspections). Having clear, accurate, and vibration-resistant 0–300 PSI gauges installed on fire pump discharge lines and hydrant risers is mandatory for verifying churn pressure, flow test results, and system readiness.
Key Features
-
0–300 PSI Standard Fire Protection Range: Covers typical fire pump shutoff (churn) pressures, operating discharge pressures, and static hydrant line pressures with optimal mid-scale readability.
-
Large 4-Inch (100mm) High-Contrast Dial: Clear black and red dual-scale markings (PSI & Bar/kPa) allow effortless reading even in dimly lit pump rooms.
-
Corrosion-Resistant Stainless Steel Case: Protects internal brass movement components against moisture, condensation, and humid pump room environments.
-
Precision Copper-Alloy Bourdon Tube: Delivers stable, repeatable accuracy (±1.5% to ±1.6% full scale) over thousands of pressure cycles.
-
Standard Bottom NPT Connection: Compatible with standard 1/4″ or 1/2″ NPT gauge cocks, snubbers, and siphon loops used in fire protection piping.
-
Shatter-Resistant Viewing Window: Heavy-duty clear polycarbonate or safety glass lens protects the dial face from accidental impact during routine pump room maintenance.
Technical Advantages
-
Reliable Mechanical Operation: Requires zero external electrical power or batteries, ensuring continuous pressure visibility even during main power failures.
-
Vibration & Surge Resistance: Built with reinforced internal movement gears (and optional glycerine fill compatibility) to handle pump startup surges without needle flutter or premature wear.
-
Code-Aligned Scale Graduations: Meets NFPA 20 and NFPA 13 gauge range requirements, which mandate that a pressure gauge’s maximum scale be at least twice the normal working pressure (ideal for 100–175 PSI fire systems).
-
Easy Isolation & Replacement: Installs cleanly onto a standard 3-way gauge test valve or isolating ball valve for fast calibration checks and swap-outs.
Applications
-
Fire Pump Discharge Manifolds: Primary pressure monitoring on electric and diesel-driven centrifugal fire pump skids.
-
Fire Hydrant & Standpipe Systems: Installed at hydrant risers, landing valve headers, and roof manifolds to verify static and residual pressures.
-
Automatic Sprinkler Systems: Used on wet and dry alarm check valve trims to monitor system side and supply side water pressure.
-
Industrial & RMG Facilities: Garment factories, textile dyeing mills, warehouses, power plants, and commercial towers across Bangladesh.
Why Choose This Product?
-
Purpose-Built for Fire Service: Designed specifically to meet fire protection piping standards rather than lightweight general-purpose plumbing gauges.
-
High Visibility & Long Service Life: Anti-corrosion housing and clear dial face prevent the fogging and rusting common in tropical climates.
-
Audit-Ready Compliance: Helps facilities pass NFPA and BNBC fire safety inspections without gauge-related non-conformity remarks.
-
Local Availability via Loop Shop: Supplied with fast nationwide delivery and engineering support in Bangladesh through Loop Engineering & Loop Shop.
4. Technical Specification Table
| Specification | Details |
| Product Name | Fire Pump & Hydrant Pressure Gauge (0–300 PSI) |
| Pressure Range | 0 – 300 PSI (Dual Scale: PSI / Bar) |
| Dial Size | 4 Inch (100 mm) Nominal Diameter |
| Sensing Element | Copper-Alloy Bourdon Tube |
| Case Material | 304 Stainless Steel |
| Connection Thread | 1/4″ NPT or 1/2″ NPT Male (Bottom Mount) |
| Window / Lens | Clear Polycarbonate / Tempered Safety Glass |
| Accuracy Class | ±1.5% / ±1.6% Full Scale (ASME B40.100 Grade A / EN 837-1) |
| Operating Medium | Water (Fire Protection, Hydrant & Sprinkler Systems) |
| Mounting Orientation | Direct Bottom Vertical Mount |
5. Features List
-
✓ Wide 0–300 PSI dual-scale dial (PSI & Bar) for fire pump and hydrant systems
-
✓ Large 4-inch (100mm) white dial face with high-contrast numerals for easy reading
-
✓ Corrosion-resistant stainless steel casing built for humid pump rooms
-
✓ Precision copper-alloy Bourdon tube and brass socket for long-term durability
-
✓ Standard bottom NPT threaded stem for quick installation on gauge cocks
-
✓ Zero power required—100% mechanical pressure sensing during emergencies
-
✓ Compliant with NFPA 20, NFPA 13, and NFPA 14 gauge range guidelines
6. Benefits For Customers
-
Instant System Diagnostics: Allows operators to immediately spot pressure drops, closed isolation valves, or pump performance issues during weekly churn tests.
-
Prevents Over-Pressurization Damage: Provides clear visual warning if relief valves malfunction or pressure surges exceed safe piping limits.
-
Pass Fire Safety Inspections Easily: Replaces broken, unreadable, or undersized gauges to ensure full compliance with RMG factory and commercial building fire audits.
-
Durable in Bangladesh’s Climate: Stainless steel body resists rust and moisture damage in non-air-conditioned pump houses across Dhaka, Gazipur, and Chattogram.
7. Installation & Maintenance Guide
Installation Requirements:
-
Always install the pressure gauge with a dedicated isolating gauge cock (shutoff valve) or 3-way test valve between the fire pipe and the gauge stem so the gauge can be isolated or replaced without draining the entire fire main.
-
Apply PTFE thread seal tape or pipe thread sealant to the male NPT threads, and tighten using a wrench only on the square brass wrench flats—never twist the gauge by its round casing.
-
Install a pressure snubber or pigtail siphon if the gauge is mounted directly downstream of high-turbulence pump discharge ports.
Maintenance Tips:
-
Inspect the dial face weekly during routine fire pump tests to verify the needle returns smoothly to zero when depressurized and reads steadily under static pressure.
-
Check for lens fogging, cracked glass, or water leakage around the threaded stem and replace immediately if damaged.
-
Cross-check gauge readings annually against a calibrated master test gauge during NFPA 25 flow testing.
Safety Instructions:
-
Close the isolating gauge valve and slowly bleed trapped pressure before unscrewing or servicing the gauge.
-
Do not exceed the maximum 300 PSI scale limit, as severe pressure spikes can permanently deform the internal Bourdon tube and ruin calibration.
8. FAQ Section
Q: What is the price of a 0–300 PSI Fire Pump Pressure Gauge in Bangladesh? A: The price of a 0–300 PSI Fire Pump & Hydrant Pressure Gauge in Bangladesh depends on dial size (4-inch standard), dry vs. liquid-filled construction, and order quantity. Contact loopshop.com.bd for current BDT pricing and bulk project rates.
Q: Where can I buy Fire Pump & Hydrant Pressure Gauges in Bangladesh? A: You can order 0–300 PSI fire protection pressure gauges online at loopshop.com.bd or through Loop Engineering, with fast delivery to Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.
Q: What warranty does this product have? A: This gauge includes a standard manufacturer defect warranty provided through Loop Shop. Reach out to our sales team with your project specifications for full warranty details.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its stainless steel casing and brass internal mechanism are specifically suited to withstand high humidity, dust, and ambient heat inside industrial pump rooms in Bangladesh.
Q: How to install this product? A: Thread the gauge’s bottom NPT connection into an isolating gauge valve using PTFE tape, tightening strictly with a spanner on the brass hex flats—never by twisting the gauge housing by hand.
Q: Why is a 0–300 PSI range recommended for fire pumps and hydrant lines? A: NFPA 20 and NFPA 13 require pressure gauges to have a maximum reading of at least twice the normal system working pressure. Since most fire pump and hydrant systems operate between 100 PSI and 175 PSI, a 0–300 PSI gauge provides ideal accuracy and safety margin.
Q: Where should pressure gauges be installed on a fire pump system? A: Under NFPA 20, a pressure gauge must be installed on the fire pump discharge manifold (between the pump discharge flange and the discharge check valve), as well as on hydrant risers and alarm check valve trims. (Note: The suction side typically uses a compound vacuum/pressure gauge).
Q: Can this gauge be used on sprinkler alarm valves as well? A: Yes, 0–300 PSI pressure gauges are standard for both the water supply side and system side of wet and dry sprinkler alarm check valves.
Q: What thread size does this pressure gauge use? A: Standard fire protection 4-inch gauges feature a 1/4″ NPT or 1/2″ NPT bottom male connection to fit standard brass gauge cocks and siphon fittings.
Q: How often should fire pump pressure gauges be checked or replaced? A: Per NFPA 25 inspection standards, gauges should be inspected visually every week/month and tested annually against a calibrated gauge—replacing any gauge that is out by more than 3% of full scale.

Reviews