Description
Product Overview
What is this product?The Winters 0–300 PSI UL Listed Fire Sprinkler Pressure Gauge (Winters Instruments PFE Series) is a heavy-duty, commercial-grade analog pressure gauge engineered specifically for fire protection piping systems.
How does it work?Connected directly to fire sprinkler risers, alarm check valves, or pump discharge headers via a 1/4″ NPT brass socket, the internal phosphor bronze Bourdon tube expands proportionally as water or air pressure increases. This mechanical movement drives a precision brass gear assembly to display exact line pressure across a large 3.5-inch white aluminum dial with high-contrast black and red graduations.
Who needs this product? Fire protection contractors, MEP engineers, factory compliance managers, and building maintenance teams installing or servicing automatic sprinkler systems, standpipes, and fire pump rooms.
Why is it useful in Bangladesh? Textile mills, garment factories, pharmaceutical plants, and commercial high-rises across Dhaka, Gazipur, Chattogram, and Narayanganj undergo rigorous fire safety inspections under BNBC, NFPA 13/25, and international buyer safety audits. Using a genuine UL-393 Listed Winters pressure gauge ensures accurate weekly pressure logging and smooth regulatory approval.
Key Features
-
UL Listed & FM Approved: Certified to UL-393 (USA and Canada) and Factory Mutual (FM) Class 2311 standards specifically for fire protection service.
-
3.5″ High-Contrast Dial: Large 90mm white aluminum face with crisp black and red markings for effortless reading from floor level in dimly lit pump rooms or riser closets.
-
0–300 PSI Measurement Range: Covers standard high-pressure fire sprinkler and standpipe operating pressures with clear dial increments.
-
Corrosion-Resistant Construction: Features a rugged black engineering plastic case, threaded polycarbonate lens, and brass wetted parts to resist rust in damp environments.
-
Internal Pointer Over-Travel Stop: Protects the internal brass movement and pointer calibration against sudden pressure surges or water hammer.
-
ASME B40.100 Compliant Accuracy: Delivers reliable ±3-2-3% (ASME Grade B) measurement accuracy across the full scale.
Technical Advantages
-
Surge & Water Hammer Resilience: Built-in pointer over-travel stop and silver-alloy welded Bourdon tube prevent needle bending during fire pump start-up spikes.
-
Moisture & Dust Protection: IP52-rated enclosure with a threaded polycarbonate window shields internal gears from pump-room humidity and dust.
-
Wide Operating Temperature Tolerance: Performs reliably from -40°C to 65°C (-40°F to 150°F), easily handling hot mechanical rooms in Bangladesh.
-
Dual-Media Compatibility: Suitable for both water-filled wet sprinkler risers and air-pressurized dry pipe systems.
Applications
-
Fire Sprinkler Risers: Wet pipe, dry pipe, pre-action, and deluge alarm check valve trim assemblies.
-
Fire Pump Rooms: Suction and discharge header pressure monitoring alongside jockey and main fire pumps.
-
Standpipe & Hydrant Networks: Zone control valve assemblies and pressure-reducing valve (PRV) stations in high-rise buildings.
-
RMG & Industrial Facilities: Garment factories, spinning mills, warehouses, and power plants requiring weekly NFPA 25 pressure inspections.
Why Choose This Product?
-
Trusted North American Brand: Winters Instruments is a globally recognized leader in industrial and fire protection instrumentation.
-
Audit-Ready Certification: Genuine UL-393 and FM markings eliminate compliance rejections during third-party factory fire safety audits.
-
Long Service Life: Backed by a 5-year manufacturer warranty and durable phosphor bronze/brass internals.
-
Reliable Local Supply: Available with fast delivery and technical support across Bangladesh from loopshop.com.bd and Loop Engineering.
4. Technical Specification Table
| Specification | Details |
| Brand | Winters Instruments |
| Series / Model | PFE Series (UL-393 Sprinkler Gauge) |
| Pressure Range | 0–300 PSI |
| Dial Size | 3.5 Inch (90 mm) |
| Dial Material & Color | White Aluminum with Black & Red Markings |
| Process Connection | 1/4″ NPT Standard, Bottom Mount |
| Certifications | UL Listed (UL-393), FM Approved, CRN Registered |
| Accuracy Standard | ±3-2-3% Full Scale (ASME B40.100 Grade B) |
| Case Material | Corrosion-Resistant Black Plastic |
| Lens Material | Threaded Polycarbonate |
| Wetted Parts | Brass Socket & Phosphor Bronze Bourdon Tube |
| Movement & Welding | Brass Movement with Silver Alloy Welding |
| Enclosure Rating | IP52 |
| Operating Temperature | -40°C to 65°C (-40°F to 150°F) |
| Maximum Working Pressure | 75% of Full Scale Value (225 PSI Continuous) |
| Compatible Media | Water and Air (Non-Clogging, Non-Corrosive) |
5. Features List
-
✓ UL-393 Listed and FM Approved for fire sprinkler systems
-
✓ Clear 0–300 PSI pressure scale on a large 3.5″ (90mm) dial
-
✓ Standard 1/4″ NPT bottom brass connection for universal riser mounting
-
✓ Corrosion-resistant black plastic housing with threaded polycarbonate lens
-
✓ Internal pointer over-travel stop protects against pressure surges
-
✓ Phosphor bronze Bourdon tube and precision brass movement
-
✓ ASME B40.100 Grade B compliant (±3-2-3% accuracy)
6. Benefits For Customers
-
Passes Fire Safety Inspections Effortlessly: Genuine UL and FM listings meet NFPA 13, NFPA 25, and Bangladesh National Building Code (BNBC) requirements.
-
Easy At-a-Glance Reading: The oversized 3.5-inch dial with bold numerals allows rapid visual checks during routine facility safety rounds.
-
Built to Resist Humidity & Corrosion: Non-corrosive case and brass internals prevent premature seizing or dial fogging in Bangladesh’s humid climate.
-
Cost-Effective Reliability: Affordable upfront cost paired with a 5-year manufacturer warranty reduces replacement frequency across multi-riser facilities.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install a 1/4″ gauge isolation valve (3-way test/shutoff cock) between the sprinkler riser or pump header and the pressure gauge so the gauge can be serviced or replaced without draining the fire system.
-
Apply PTFE thread seal tape or approved pipe sealant to the 1/4″ NPT male brass threads.
-
Always tighten the gauge using a wrench on the brass hex wrench flats above the threads—never twist the plastic case by hand.
Maintenance Tips:
-
Inspect the gauge weekly per NFPA 25 guidelines to verify the needle returns smoothly to zero when pressure is bled via the 3-way test valve.
-
Replace the gauge immediately if the polycarbonate lens cracks, water enters the dial face, or the pointer fails to zero.
-
Recalibrate or replace fire sprinkler pressure gauges every 5 years in accordance with NFPA 25 inspection standards.
Safety Instructions:
-
Close the gauge isolation valve and bleed trapped line pressure completely before unscrewing the gauge from any pressurized fire main.
-
Do not exceed the recommended continuous working pressure of 75% of full scale (225 PSI) to maintain long-term accuracy.
8. FAQ Section
Q: What is the price of Winters 0–300 PSI UL Pressure Gauge in Bangladesh? A: The price of the Winters 0–300 PSI UL Listed Fire Sprinkler Pressure Gauge in Bangladesh depends on order volume and current stock availability. Visit loopshop.com.bd or contact Loop Engineering for the latest BDT unit and project pricing.
Q: Where can I buy Winters 0–300 PSI Pressure Gauge in Bangladesh? A: You can order genuine Winters Instruments UL Listed pressure gauges online at loopshop.com.bd with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial zones in Bangladesh.
Q: What warranty does this product have?A: The Winters PFE Series Sprinkler Pressure Gauge carries a 5-year manufacturer warranty against defects in material and workmanship, supported locally by Loop Shop.
Q: Is this suitable for the Bangladesh climate? A: Yes. With an operating range of -40°C to 65°C, IP52 enclosure rating, and corrosion-resistant case, it performs reliably in humid and warm fire pump rooms across Bangladesh.
Q: How to install this product?A: Thread the 1/4″ NPT bottom brass connection into a gauge isolation/test valve on your sprinkler riser using PTFE tape, tightening strictly on the brass wrench flats.
Q: Is this gauge UL Listed for RMG factory fire safety audits?A: Yes, it is UL-393 Listed and FM Approved specifically for fire protection systems, making it fully compliant with NFPA 13/25 and factory safety audits.
Q: Can this gauge be used for both water and air sprinkler systems?A: Yes, the Winters PFE 0–300 PSI series is rated for both water-filled wet sprinkler risers and pressurized air in dry-pipe sprinkler systems.
Q: Why is a 0–300 PSI range recommended over a 0–160 PSI gauge? A: NFPA 13 requires pressure gauges to have a maximum limit of at least twice the normal working pressure. A 0–300 PSI gauge safely covers normal system pressures up to 150–225 PSI without over-ranging.
Q: What is the dial size and thread size of this gauge?A: It features a large 3.5-inch (90mm) dial face and a standard 1/4″ NPT bottom connection.
Q: How often should fire sprinkler pressure gauges be replaced? A: Under NFPA 25 maintenance rules, fire sprinkler pressure gauges must be replaced or calibrated against a master gauge every 5 years.

Reviews
There are no reviews yet.