Description
Product Overview
What is this product? The UL Listed 2-1/2″ (65 mm) Class I Landing Valve (also known as a Fire Hydrant Angle Hose Valve) is a heavy-duty manual isolation and flow-control valve installed on wet or dry standpipe risers inside stairwells, corridors, and external yard hydrant cabinets.
How does it work? Connected directly to a pressurized fire standpipe riser, the valve remains closed under normal standby conditions and is sealed against dust and debris with a tethered blank cap. During a fire emergency, firefighters remove the protective cap, couple a 2-1/2″ (65 mm) fire hose to the outlet, and turn the cast handwheel counter-clockwise to open the internal disc assembly, delivering high-volume water directly to the fire nozzle.
Who needs this product? MEP contractors, fire protection engineers, factory compliance managers, and building developers installing or upgrading Class I and Class III standpipe and fire hydrant networks.
Why is it useful in Bangladesh? Garment factories (RMG), spinning and dyeing mills, pharmaceutical plants, and multi-story commercial buildings across Dhaka, Gazipur, Chattogram, and Narayanganj face mandatory fire audits under BNBC, NFPA 14, and international buyer safety standards. A genuine UL Listed 2-1/2″ (65 mm) Class I landing valve ensures reliable operation under high riser pressure and eliminates audit non-conformities.
Key Features
-
UL Listed Certification: Independently tested and UL Listed for Class I fire protection standpipe service.
-
Standard 2-1/2″ (65 mm) Size: Delivers full firefighting flow capacity (minimum 250 GPM / ~950 LPM per NFPA 14 Class I requirements) for trained fire brigade personnel.
-
Heavy-Duty Copper Alloy Construction: Forged or cast brass/bronze body and stem resist internal corrosion, mineral scaling, and high hydraulic surge pressures.
-
High-Visibility Ergonomic Handwheel: Red-painted cast iron/aluminum handwheel with clear OPEN/CLOSE directional markings for fast operation under low-visibility smoke conditions.
-
Protective Cap & Retaining Chain: Supplied with a heavy-duty blanking cap and chain to protect outlet threads/lugs from physical impact, paint, and dust accumulation.
-
Resilient Elastomer Disc Seal: Ensures drip-tight shutoff against high static standpipe pressures without weeping.
Technical Advantages
-
High Working Pressure Rating: Built to withstand continuous static standpipe pressures up to 300 PSI (20.7 bar) / 175–250 PSI standard operating ranges without seat deformation.
-
Low Friction Loss Design: Streamlined internal globe/angle waterway minimizes pressure drop across the valve during full-bore fire hose discharge.
-
Long Service Life: Dezincification-resistant copper alloy wetted components prevent stem seizure even after years of static standby.
-
Easy Field Servicing: Top-entry bonnet design allows straightforward inspection and replacement of the rubber seat disc and stem packing without removing the valve from the riser.
Applications
-
RMG & Textile Factories: Internal stairwell standpipe risers and external yard fire hydrant hose cabinets.
-
High-Rise Commercial & Residential Towers: Floor-by-floor fire landing points in shopping malls, corporate offices, and hotels.
-
Warehouses & Logistics Hubs: High-hazard storage facilities requiring Class I heavy hose stream coverage.
-
Industrial & Pharma Plants: Dedicated fire protection loops in economic zones (BEPZA, BSEZ, Gazipur, Ashulia, Savar).
Why Choose This Product?
-
Full Compliance Assurance: Meets NFPA 14 Class I standpipe specifications and carries genuine UL Listing (AE or equivalent international approved brands).
-
Built for Heavy Industrial Use: Engineered to endure rough handling during emergency fire brigade connections and annual hydrostatic testing.
-
Ready for Immediate Installation: Includes matching blank cap and chain for complete hose cabinet or riser mounting.
-
Trusted Local Supply: Sourced, verified, and supported in Bangladesh by Loop Engineering & Loop Shop.
4. Technical Specification Table
| Specification | Details |
| Product Name | Landing Valve 2-1/2″ (65 mm) — Class I |
| Brand / Origin | AE or Equivalent (UL Listed International Brand) |
| Nominal Size | 2-1/2 Inch (65 mm / DN65) |
| Standpipe Classification | Class I (NFPA 14 Fire Department Connection) |
| Certification | UL Listed (Fire Protection Service) |
| Valve Pattern | Angle / Oblique Globe Type |
| Body & Bonnet Material | Corrosion-Resistant Brass / Bronze Alloy |
| Handwheel Material | Red Powder-Coated Cast Iron / Aluminum Alloy |
| Seat Disc Material | Heavy-Duty Nitrile / EPDM Elastomer |
| Inlet Connection | 2-1/2″ NPT / BSP Threaded or Flanged (Project Specific) |
| Outlet Connection | 2-1/2″ (65 mm) NST Male Thread or Instantaneous Female (with Cap & Chain) |
| Working Pressure | Up to 300 PSI (20 Bar) |
5. Features List
-
✓ UL Listed for Class I and Class III standpipe fire protection systems
-
✓ Full 2-1/2″ (65 mm) bore for high-volume fire brigade hose lines
-
✓ Heavy-duty brass/bronze construction for superior corrosion resistance
-
✓ Rated for high-pressure standpipe risers up to 300 PSI
-
✓ Red high-visibility handwheel with clear open/close direction arrows
-
✓ Complete with tethered protective blank cap and retaining chain
-
✓ Drip-tight resilient seat seal prevents riser leakage
6. Benefits For Customers
-
Passes Fire Safety Audits: Genuine UL Listing satisfies BNBC, NFPA 14, and international factory compliance inspections on the first check.
-
Rapid Emergency Response: Smooth-operating spindle and rugged outlet threads allow firefighters to connect and charge 65 mm hoses within seconds.
-
Zero Riser Leakage: Precision-machined seat and elastomer disc hold high static pump pressure without dripping inside stairwells or cabinets.
-
Reliable in Bangladesh Environments: Brass/bronze metallurgy resists rust and mineral buildup caused by humid pump rooms and local groundwater.
7. Installation & Maintenance Guide
Installation Requirements:
-
Mount the landing valve on the standpipe riser outlet at an accessible height between 0.9 m and 1.5 m (3 ft to 5 ft) above the finished floor level per NFPA 14 guidelines.
-
Orient the outlet downward or at an oblique angle so connected fire hoses hang naturally without kinking.
-
Apply UL-approved thread sealant or flange gaskets depending on the inlet configuration, and ensure adequate clearance around the handwheel for full rotation.
Maintenance Tips:
-
Inspect monthly to verify the blank cap and chain are attached, the handwheel turns freely, and no water is weeping past the seat.
-
Exercise the valve stem annually during standpipe flow and hydrostatic pressure tests, lubricating the external spindle threads lightly with silicone-based grease.
-
Inspect the outlet rubber washer/gasket periodically and replace if cracked or hardened.
Safety Instructions:
-
Never attempt to remove the valve bonnet or service internal components while the standpipe riser is pressurized.
-
Keep the area around the landing valve and fire hose cabinet completely clear of stored goods or obstructions at all times.
8. FAQ Section
Q: What is the price of a 2-1/2″ (65 mm) UL Listed Landing Valve in Bangladesh? A: Pricing depends on the selected brand (AE or equivalent UL Listed manufacturer), inlet type (threaded vs. flanged), and project quantity. Contact loopshop.com.bd directly for an exact BDT quotation.
Q: Where can I buy UL Listed Class I Landing Valves in Bangladesh? A: You can order genuine UL Listed 2-1/2″ (65 mm) landing valves online from loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.
Q: What warranty does this product have? A: This product includes a manufacturer defect warranty backed by Loop Shop. Contact our engineering team with your project BOQ for formal warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. The corrosion-resistant brass/bronze body and coated handwheel are built to withstand high humidity, dust, and local water conditions across Bangladesh.
Q: How to install this product? A: Install the 2-1/2″ inlet onto the standpipe branch connection at 3–5 feet above floor level using approved thread sealant or flange bolts, ensuring the outlet points downward/obliquely with full clearance for the handwheel.
Q: What does “Class I” mean for a landing valve? A: Under NFPA 14, a Class I standpipe system provides 2-1/2″ (65 mm) hose connections specifically designed to supply high-volume water streams for trained firefighters and fire department personnel.
Q: Does the valve come with a cap and chain? A: Yes, each landing valve is supplied complete with a matching protective blank cap and retaining chain to protect the outlet connection.
Q: What outlet connection types are available? A: Depending on your site standard, 2-1/2″ (65 mm) landing valves are supplied with either 2-1/2″ NST (NH) Male Threaded outlets or 65 mm BS 336 Instantaneous Female couplings.
Q: Is this valve suitable for both wet and dry standpipe risers? A: Yes, it is rated for permanently pressurized wet risers as well as dry standpipe and yard hydrant systems.
Q: Are UL certificates and data sheets provided for factory compliance? A: Yes, Loop Engineering provides complete technical data sheets and UL Listing verification documents for your fire safety audit submittals.

Reviews