AE 2-Way Fire Brigade Connection (Breeching Inlet) — Kitemark

      • Primary Purpose: Provides an external water injection point allowing fire brigade vehicles to pump pressurized water directly into dry/wet risers, fire hydrants, and sprinkler networks.

      • Key Specifications: Model Fig.136, dual 2.5-inch (65 mm) instantaneous male inlets with built-in non-return valves, 100 mm (4″) PN16 flanged outlet, and BSI Kitemark certification (KM551498) under BS 5041 Part 3.

      • Customer Benefits: Prevents backflow through spring-loaded check valves, resists internal corrosion via epoxy coal-tar coating, and passes strict fire safety compliance audits.

      • Bangladesh Market Relevance: Engineered for RMG factories, high-rise commercial towers, and industrial plants in Bangladesh requiring BS/NFPA-compliant fire department connections and Fire Service & Civil Defence (FSCD) readiness.

Best Price Guaranteed

Description

Product Overview

What is this product? The AE Fig.136 2-Way Breeching Inlet (Fire Brigade Connection) is a heavy-duty, BSI Kitemark-approved fire protection valve assembly installed on the exterior walls of buildings and industrial facilities.

How does it work? During a fire emergency, Bangladesh Fire Service & Civil Defence (FSCD) personnel connect two 2.5-inch (65 mm) delivery hoses from their fire tender directly to the twin instantaneous male inlets. Internal spring-loaded non-return valves open under incoming water pressure to supply the building’s dry riser, wet riser, or sprinkler piping, while automatically closing to prevent reverse water flow when pumping stops or when only one inlet is pressurized.

Who needs this product? MEP contractors, fire protection engineers, RMG textile factory owners, commercial real estate developers, and facility safety managers building or upgrading compliant fire hydrant and riser systems.

Why is it useful in Bangladesh? Industrial plants, garment factories, hospitals, and high-rise commercial buildings across Dhaka, Gazipur, Chattogram, and Narayanganj must maintain accessible, code-certified fire brigade connections for rapid external water replenishment during emergencies and for passing RSC, BNBC, and international buyer fire safety inspections.

Key Features

  • BSI Kitemark Certified (KM551498): Manufactured and tested in accordance with BS 5041: Part 3: 1975 and listed under SETSCO PLS Class 1A.

  • Dual 2.5″ Instantaneous Male Inlets: Equipped with two 65 mm BS 336 instantaneous male inlets for rapid, secure hose coupling by fire brigade crews.

  • Integrated Non-Return Valves: Each inlet features a dedicated gunmetal/copper alloy check valve with a bronze spring to prevent backflow and allow single-hose operation.

  • Heavy-Duty Spheroidal Graphite Iron Body: High-strength ductile casting finished externally in high-visibility red and internally coated with black epoxy coal-tar paint for superior corrosion resistance.

  • 100 mm (4″) PN16 Flanged Outlet: Standard 4-inch PN16 flat-face outlet flange (with optional BS10 Table D/E or ANSI #150 drilling) for direct connection to riser mains.

  • Protective Blank Caps with Chains: Supplied with durable rubber blank caps secured with chrome chains (optional brass/gunmetal caps available) to keep dust, insects, and debris out of the inlets.

Technical Advantages

  • Hydrostatically Tested Reliability: Every unit undergoes factory hydrostatic body testing at 20 bar (~300 PSI) and low-pressure non-return valve seat testing at 1.7 bar (~25 PSI) to guarantee zero leakage.

  • Corrosion-Resistant Internal Metallurgy: Wetted inlet components are cast from BS1400 LG2 gunmetal and copper alloy with stainless steel locknuts and washers to withstand long-term stagnant water exposure.

  • Low-Maintenance Design: Compact casting geometry with smooth internal waterways minimizes friction loss and requires minimal routine servicing.

  • Drain Valve Provision: Built-in drain connection allows trapped water to be safely drained after testing, preventing stagnation and internal scaling.

Applications

  • Industrial & RMG Factories: Exterior hydrant and sprinkler riser connections for textile mills, dyeing plants, and export-oriented garment factories.

  • Commercial High-Rise Buildings: Office towers, shopping complexes, and hotels requiring dry or wet riser fire brigade access.

  • Residential & Institutional: High-rise apartment complexes, universities, and hospitals requiring BNBC-compliant fire service connections.

  • Project Installations: New turnkey fire hydrant installations, fire brigade cabinet assemblies, and industrial safety retrofits.

Why Choose This Product?

  • Verified International Certification: Genuine BSI Kitemark (KM551498) approval provides immediate documentation credibility for RSC, DIFE, and FSCD inspections.

  • Built for Long Service Life: Ductile iron casting combined with LG2 gunmetal internals and coal-tar epoxy lining resists humidity and water corrosion in Bangladesh.

  • Leak-Free Check Valve Sealing: Tested down to 1.7 bar low pressure so water never escapes when charging a single inlet.

  • Reliable Supply from Loop Shop: Available with engineering support, matching companion flanges, and breeching inlet cabinets via loopshop.com.bd.

4. Technical Specification Table

Specification Details
Model Fig.136 (2-Way Breeching Inlet)
Brand AE
Design Standard BS 5041: Part 3: 1975
Approvals & Certifications BSI Kitemark (KM551498), SETSCO Listed (PLS Class 1A)
Inlet Connection 2 × 2.5″ (65 mm) BS 336 Male Instantaneous Couplings
Outlet Connection 100 mm (4″) PN16 Flat-Face Flange (BS10 Table D/E & ANSI #150 optional)
Body Material Spheroidal Graphite (Ductile) Iron
Inlet & Check Valve Material BS1400 LG2 Gunmetal & Copper Alloy with Bronze Spring
Fasteners Stainless Steel Locknut & Washer
Internal Coating Black Epoxy Coal-Tar Anti-Corrosion Paint
Blank Caps Rubber Blank Caps with Chrome Chain (Brass/Gunmetal optional)
Body Hydrostatic Test Pressure 20 Bar (approx. 300 PSI)
Non-Return Valve Test Pressure 1.7 Bar (approx. 25 PSI)

5. Features List

  • ✓ BSI Kitemark certified (KM551498) to BS 5041: Part 3: 1975

  • ✓ Dual 2.5″ (65 mm) instantaneous male inlets with integrated check valves

  • ✓ Heavy-duty spheroidal graphite iron body with 100 mm (4″) PN16 flanged outlet

  • ✓ BS1400 LG2 gunmetal internals with bronze springs and stainless steel trim

  • ✓ Internal black epoxy coal-tar coating for superior corrosion protection

  • ✓ Factory hydrostatic tested to 20 bar (300 PSI) body / 1.7 bar (25 PSI) seat

  • ✓ Supplied complete with protective blank caps and securing chains

6. Benefits For Customers

  • Passes Fire Safety Audits Smoothly: Recognized BSI Kitemark certification satisfies industrial compliance engineers and fire safety auditors across Bangladesh.

  • Prevents Backflow & Pressure Loss: Dual independent non-return valves ensure water flows strictly into the riser system even if only one fire hose is connected.

  • Resists Rust & Stagnant Water Damage: Gunmetal wetted parts and internal coal-tar epoxy coating eliminate premature seizing and corrosion.

  • Fast Emergency Connection: Standard BS 336 instantaneous couplings enable firefighters to lock hoses in place within seconds.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the breeching inlet horizontally on an external building wall or inside a recessed/surface-mounted Fire Brigade Inlet Cabinet at an accessible height (typically 750 mm to 1,000 mm above finished ground level) facing the fire engine access road.

  • Bolt the 100 mm (4″) PN16 outlet flange to the riser piping using a full-face rubber gasket and high-tensile bolts, ensuring the directional flow arrow points into the building riser.

  • Provide clear exterior signage reading “FIRE BRIGADE INLET” or “DRY/WET RISER INLET”.

Maintenance Tips:

  • Inspect the rubber blank caps, chains, and instantaneous male lugs every 3 months to ensure no physical damage or missing caps.

  • Manually depress the non-return valve discs during annual hydrant servicing to verify smooth spring travel and debris-free seating.

  • Check the cabinet drain and valve drain plug after hydrostatic testing to ensure no stagnant water remains inside the body.

Safety Instructions:

  • Never block or obstruct the exterior access area in front of the breeching inlet with parked vehicles, storage crates, or fencing.

  • Depressurize the riser system completely before unbolting the outlet flange or servicing internal check valve assemblies.

8. FAQ Section

Q: What is the price of AE 2-Way Fire Brigade Connection (Breeching Inlet) in Bangladesh? A: The price of the AE Fig.136 2-Way Kitemark Breeching Inlet in Bangladesh depends on flange specification, optional cabinet accessories, and project quantity. Contact loopshop.com.bd for current BDT pricing and contractor quotes.

Q: Where can I buy AE 2-Way Breeching Inlet in Bangladesh? A: You can order genuine BSI Kitemark-approved AE 2-Way Breeching Inlets directly from loopshop.com.bd or through Loop Engineering, with fast delivery to Dhaka, Gazipur, Chattogram, Narayanganj, and industrial zones nationwide.

Q: What warranty does this product have? A: The AE Fig.136 2-Way Breeching Inlet includes a manufacturer defect warranty backed by Loop Shop. Reach out to our sales team for project-specific warranty documentation.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its spheroidal graphite iron body, internal black epoxy coal-tar coating, and BS1400 LG2 gunmetal internals are specifically engineered to withstand high humidity, monsoon exposure, and local water conditions in Bangladesh.

Q: How to install this product?A: Mount the unit inside an exterior breeching inlet cabinet or directly on an exterior wall at fire brigade access height, connect the 100 mm (4″) PN16 outlet flange to the riser pipe, and ensure unobstructed access from the main driveway.

Q: What certification does the AE Fig.136 2-Way Breeching Inlet hold?A: It is certified with the BSI Kitemark (License No. KM551498) to BS 5041: Part 3: 1975 and listed under SETSCO PLS Class 1A.

Q: What size are the inlet and outlet connections?A: It features two 2.5-inch (65 mm) BS 336 instantaneous male inlets and a standard 100 mm (4-inch) PN16 flanged outlet.

Q: Does this breeching inlet have built-in non-return valves? A: Yes. Each of the two inlets incorporates an individual spring-loaded non-return (check) valve tested at 1.7 bar low pressure to prevent water backflow.

Q: Can I order this breeching inlet with an ANSI #150 flange instead of PN16? A: Yes. While 100 mm PN16 flat-face is standard, ANSI #150 (FF or RF) and BS10 Table D/E flange drillings are available upon project request.

Q: What is the difference between a 2-way and 4-way breeching inlet? A: A 2-way breeching inlet (4″ outlet) serves standard dry/wet riser mains, whereas a 4-way breeching inlet (6″ outlet) is used for larger high-demand hydrant and sprinkler networks requiring simultaneous supply from up to four fire brigade hoses.

Reviews

There are no reviews yet.

Be the first to review “AE 2-Way Fire Brigade Connection (Breeching Inlet) — Kitemark”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support