Fiffco DN150 200 mm (8″) Flanged Y-Strainer Non-Listed for Fire & Water

        • Core Protection Purpose: Mechanically filters rust, scale, weld slag, and solid debris from high-flow pipelines to safeguard fire pumps, check valves, flow meters, and control valves from clogging or internal damage.

        • Heavy-Duty Engineering Specifications: Built with a fusion-bonded epoxy-coated ductile iron body, a removable perforated stainless steel strainer screen, a bolted retainer cap with drain plug, and PN16 / ANSI Class 125–150 flanged connections.

        • Operational & Maintenance Benefits: Engineered with a low-pressure-drop Y-pattern profile and bottom cleanout access so facility teams can flush or clean the screen without disassembling the main 8-inch pipework.

        • Bangladesh Industrial Relevance: Ideal for cost-effective non-listed fire hydrant networks, pump rooms, HVAC chillers, and utility water lines across garment factories, textile mills, and commercial complexes in Bangladesh.

Best Price Guaranteed

Description

Product Overview

The Fiffco 200 mm (8″) Flanged Y-Strainer (Non-Listed) is a heavy-duty mechanical pipeline filtration unit engineered to capture solid impurities suspended in flowing water or neutral fluids. Installed upstream of critical mechanical equipment, it traps suspended particles inside an angled cylindrical stainless steel mesh basket before the fluid passes downstream.

The Y-shaped housing directs incoming flow through the perforated stainless steel screen while keeping hydraulic resistance low. As debris accumulates inside the strainer basket, maintenance personnel can shut down the line, open the drain plug or unbolt the retainer cap, and remove the screen for cleaning without disturbing the bolted flange joints.

MEP contractors, fire protection engineers, factory maintenance managers, and HVAC installers rely on 200 mm (8″) Y-strainers for main suction and header lines. In Bangladesh—where municipal water lines, overhead tanks, and underground reservoirs frequently carry sediment, rust flakes, and construction debris—installing an 8-inch ductile iron Y-strainer prevents costly pump impeller damage and valve seat failure in RMG factories, industrial plants, and high-rise commercial projects.

Key Features

  • Ductile Iron Construction: High-strength ductile iron body and cover withstand mechanical pipe stress and pressure surges in 8-inch header lines.

  • Perforated Stainless Steel Screen: Corrosion-resistant internal stainless steel mesh captures solid particulates without rusting or collapsing under flow.

  • Fusion-Bonded Epoxy Coating: Internal and external epoxy coating protects the casting against corrosion in humid and wet pump-room environments.

  • Bolted Retainer Cap with Drain Plug: Allows rapid blowdown flushing via the drain plug and straightforward screen extraction for thorough servicing.

  • Standardized Flanged Ends: Precision-drilled flanges ensure secure, leak-free bolt-up with standard 200 mm (8″) industrial piping systems.

  • Non-Listed Commercial Grade: Delivers dependable mechanical filtration for projects that do not require UL/FM certification.

Technical Advantages

  • Low Pressure Drop Hydraulics: The streamlined Y-leg geometry minimizes turbulence and head loss across 200 mm main lines, preserving pump suction head and system flow efficiency.

  • Rugged Structural Integrity: Ductile iron casting offers superior tensile strength and impact resistance compared to standard grey cast iron.

  • Downstream Equipment Protection: Prevents abrasive grit and scale from scoring pump seals, jamming non-return valves, or fouling heat exchanger tubes.

  • Zero Pipe-Removal Servicing: Top/bottom bolted cover access eliminates the need to unbolt heavy 8-inch line flanges during routine cleaning.

Applications

  • Industrial & Factory Utilities: Main water supply headers, cooling towers, and process water filtration in textile, dyeing, pharmaceutical, and manufacturing plants.

  • Fire Protection Systems (Non-Listed): Fire pump suction headers, hydrant ring mains, and sprinkler supply lines where non-listed components are specified.

  • Commercial HVAC Systems: Chilled water and condenser water loops in shopping malls, hospitals, and corporate towers.

  • Project & Municipal Water Infrastructure: Booster pump stations, water treatment plant intake lines, and high-rise plumbing risers.

Why Choose This Product?

  • Proven Operational Reliability: Built to handle continuous-duty industrial and fire-water service without screen deformation or body corrosion.

  • Consistent Hydraulic Performance: Engineered to maintain steady flow rates across large-bore 200 mm pipelines while trapping damaging debris.

  • High Cost-Effectiveness: Provides heavy-duty ductile iron and stainless steel construction at an economical price point for non-listed B2B and commercial tenders.

  • Local Supply & Support: Available through loopshop.com.bd with local technical consultation, fast delivery across Bangladesh, and easy replacement gasket or screen sourcing.

4. Technical Specification Table

Specification Details
Model 200 mm (8″) Flanged Y-Strainer (Non-Listed)
Brand Fiffco (or Equivalent)
Nominal Size 200 mm (8 Inch / DN200)
Body & Cover Material Ductile Iron
Filter Screen Material Perforated Stainless Steel
Surface Coating Fusion-Bonded Epoxy Coated
End Connection Flanged (EN 1092-2 PN16 / ANSI Class 125–150)
Working Pressure 16 Bar / 250 PSI (Standard PN16 / 250 PSI Class)
Hydrostatic Test Pressure 24 Bar (Shell Test)
Cleanout Provision Bolted Retainer Cap with Drain / Blowdown Plug
Operating Temperature -10°C to 80°C (EPDM/Rubber Gasket) / up to 120°C–200°C (Graphite)
Certification Status Non-Listed
Warranty Manufacturer Standard Warranty (Contact Loop Shop for Terms)

5. Features List

  • Heavy-duty ductile iron body with corrosion-resistant fusion-bonded epoxy finish

  • Removable perforated stainless steel filter basket for fine particle capture

  • Bolted cover with integrated drain plug for quick flushing and cleanout

  • Standard 200 mm (8″) flanged ends compatible with PN16 and Class 125/150 piping

  • Low-pressure-drop Y-pattern flow path for optimal pump suction performance

  • Cost-effective non-listed solution for commercial, HVAC, and industrial water pipelines

6. Benefits For Customers

  • Protects Expensive Pumps & Valves: Prevents solid debris, rust, and welding slag from damaging pump impellers, mechanical seals, and check valves.

  • Reduces Unplanned Downtime: Routine flushing through the drain plug or screen removal via the bolted cover keeps plant operations running smoothly.

  • Lowers Maintenance Costs: Eliminates the labor and crane/rigging time needed to unbolt an 8-inch strainer from the main pipeline during cleaning.

  • Built for Bangladesh Water & Climate Conditions: Epoxy-coated ductile iron and stainless steel internals resist rust and humidity in local pump rooms and underground water systems.

7. Installation & Maintenance Guide

  • Installation Requirements:

    • Verify that the flow direction arrow cast onto the strainer body aligns with the pipeline flow direction.

    • Install the strainer horizontally with the Y-leg (retainer cap) pointing vertically downward so trapped debris collects in the basket and does not fall back into the pipe during shutdown.

    • For vertical pipelines, install only on downward-flowing lines; never install on upward-flowing vertical risers.

    • Leave sufficient clearance below the retainer cap to allow full withdrawal of the stainless steel filter screen.

    • Support the adjacent 8-inch pipework independently so the strainer flanges do not bear excessive piping weight.

  • Maintenance Tips:

    • Monitor differential pressure across the strainer using upstream and downstream pressure gauges; clean the screen whenever pressure drop increases noticeably.

    • Perform periodic blowdown flushing via the bottom drain plug to clear loose sediment.

    • During scheduled shutdowns, remove the bolted cover, inspect the stainless steel mesh for tears or deformation, rinse thoroughly, and replace the cover gasket if worn.

  • Safety Instructions:

    • Always isolate upstream and downstream isolation valves and completely depressurize and drain the pipeline before loosening the drain plug or cover bolts.

    • Wear appropriate PPE (safety glasses, gloves, and protective footwear) when opening the strainer housing, especially in hot-water or pressurized pump systems.

    • Tighten cover and flange bolts evenly in a star/cross pattern to ensure uniform gasket compression and prevent leaks.

8. FAQ Section

Q: What is the price of Fiffco 200 mm (8″) Y-Strainer in Bangladesh? A: The price of a Fiffco (or equivalent) 200 mm (8″) Non-Listed Y-Strainer in Bangladesh varies based on flange drilling standard (PN16 or ANSI Class 125/150), quantity, and current import rates. Contact loopshop.com.bd directly for the latest BDT unit price and corporate project quotation.

Q: Where can I buy Fiffco 200 mm (8″) Y-Strainer in Bangladesh? A: You can order the Fiffco 200 mm (8″) Flanged Y-Strainer online at loopshop.com.bd or through Loop Engineering’s corporate sales team in Dhaka for nationwide delivery across Bangladesh.

Q: What warranty does this product have? A: This product carries a standard manufacturer warranty covering casting and material defects under normal operating pressure and temperature conditions. Reach out to Loop Shop support for specific project warranty documentation.

Q: Is this Y-strainer suitable for Bangladesh climate and water conditions? A: Yes. Its fusion-bonded epoxy-coated ductile iron body and stainless steel perforated screen are specifically designed to resist high humidity, ambient heat, and sediment-heavy water commonly found in Bangladesh factories and commercial buildings.

Q: How to install this 200 mm (8″) Y-strainer properly?A: Bolt the strainer between matching 8-inch companion flanges with appropriate gaskets, ensuring the arrow on the body points in the direction of water flow. Mount it horizontally with the strainer leg facing downward and leave clearance underneath to remove the screen.

Q: What is the difference between Non-Listed and UL/FM Listed Y-strainers?A: A Non-Listed Y-strainer meets standard industrial dimensional and pressure ratings (such as PN16 / 250 PSI) at a lower cost, whereas UL/FM Listed strainers undergo third-party fire-protection testing and certification required by international compliance audits (such as RSC/Accord or NFPA-mandated facilities).

Q: Which flange standard does this 8-inch Y-strainer fit?A: Standard Fiffco 200 mm (8″) ductile iron Y-strainers are available with flanges drilled to EN 1092-2 PN16 or ANSI B16.1 Class 125 / B16.5 Class 150. Confirm your matching pipe flange standard when placing your order.

Q: Can this strainer be used in a fire pump suction line? A: Yes, it is widely used on fire pump suction headers and hydrant lines in projects where Non-Listed mechanical valves and fittings are acceptable.

Q: How often should the stainless steel screen be cleaned? A: Cleaning frequency depends on water cleanliness. Newly commissioned pipelines should be inspected after the first 24–48 hours of flushing, followed by scheduled quarterly checks or whenever pressure drop across the strainer rises.

Q: Do you supply replacement screens and gaskets in Bangladesh? A: Yes, loopshop.com.bd supports B2B and industrial clients with spare stainless steel filter baskets, EPDM gaskets, and matching flange bolts and nuts.

Reviews

There are no reviews yet.

Be the first to review “Fiffco DN150 200 mm (8″) Flanged Y-Strainer Non-Listed for Fire & Water”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581