Simplex 4100-3109 Loop Card

• Manufacturer Portfolio: Simplex Fire Panels by Johnson Controls
• Robust System Scaling: Provides a master 250-point capacity link to addressable devices
• Multi-Loop Isolation: Features short-circuit isolation barriers between output loops
• Premium Noise Immunity: Electrically isolated design shields lines from common-mode voltage noise
• Hardware Legacy Cross-Compatibility: Serves as a direct drop-in replacement for older 4100-3101 and 4100-3106 modules
• Motherboard Expansion Space: Compact block card template accommodates two optional expansion loop modules

Best Price Guaranteed

Description

The Simplex 4100-3109 Loop Card is an enterprise-grade fire alarm panel component engineered to provide robust addressable loop expansion for intelligent fire command systems. Functioning as a high-performance IDNet 2 Interface Module, this card installs securely into the control bay or expansion slots of Simplex 4100 series emergency power systems (EPS). By managing up to 250 individual initiating and notification points over a supervised two-wire circuit, the Simplex 4100-3109 Loop Card serves as a critical network backbone for complex commercial spaces, multi-story high-rises, and industrial manufacturing plants.

Technical Specifications Table

Model Assignment 4100-3109 (IDNet 2 Addressable Interface Module)
Manufacturer Family Intelligent Panel Interface Components by Simplex (Johnson Controls)
Country of Origin Mexico
Loop Address Protocol IDNet 2 Addressable Protocol (Backward compatible with MAPNET II devices)
Total Device Point Capacity 250 Addressable Points maximum intermixed monitor and control points
Integrated Loop Segments 2 Loop Outputs (Configurable as 1 Class A loop or 2 Class B loop lines)
Isolation Protection Electrically isolated channels with independent short-circuit separation barriers
Data Communication Rate High-speed polling loop operating at a data transfer rate of 3333 bps
Channel Operating Voltage 30 VDC nominal under standard conditions | 35 VDC maximum during alarm events
Internal Power Demand 19.5 VDC to 32 VDC supply requirement | 350 mA maximum continuous current
Device Allocation Footprint Occupies exactly 1 Block space configuration within the panel expansion bay
Wiring Terminal Support Front-facing screw block nodes accepting field wire sizes from 18 to 12 AWG
Operating Temperature Range 32°F to 120°F (0°C to 49°C) optimized for standard conditioned panel bays
Relative Humidity Limit Up to 93% RH at 90°F (32°C) non-condensing moisture boundaries
Agency List Compliance UL 864 Listed, ULC Listed, FM Approved, CSFM Certified, OTCR NYC Accepted

⚙️ Engineering & Architecture Resources

Review national life-safety layout guidelines, loop calculations, and installation mandates outlined under official NFPA 72 Fire Alarm Code Standards before executing final panel terminal connections for the Simplex 4100-3109 Loop Card infrastructure.

📥 Download Official Technical Manual (579-1169)

Bi-Directional Isolated Wiring Logic & Advanced On-Board Troubleshooting Diagnostics

The standout advantage of upgrading or repairing fire enclosures with a premium Simplex 4100-3109 Loop Card centers on its advanced electrical isolation layout. Both output circuits are completely isolated from standard system reference voltages, which prevents common-mode ground noise from messing with adjacent building wires. When a Class A wiring layout is selected for the Simplex 4100-3109 Loop Card, the loop establishes an alternate, bi-directional path. If a single open circuit break occurs down the line, the card instantly reroutes data commands through both sides, keeping 100% of your field sensors completely active. Alternatively, in Class B setups, the card supports extensive branch T-tapping, which saves major installation labor and copper materials during complex retrofits.

For immediate on-site maintenance, the internal architecture of the Simplex 4100-3109 Loop Card includes a dedicated row of eight diagnostic troubleshooting LEDs. Instead of forcing technicians to hook up complex testing equipment just to diagnose a line fault, the board instantly isolates errors via specific visual indicators. Dedicated LEDs activate for separate loop troubles, negative earth ground faults, and positive earth ground faults. Furthermore, during a live system test, the host plastic loop devices can flash or latch steadily on at the same time, giving inspecting engineers a clear visual map to verify system-wide loop communication integrity.

  • Short-Circuit Isolation Security: If a short-circuit wiring fault occurs beyond the card terminals, that specific loop segment is instantly separated, preventing a single failure from crashing the other loops.
  • Base-Mounted Address DIP Switches: Uses an 8-position binary DIP switch configuration block to map the card address inside the ES panel programmer software before final hardware installation.
  • Daughter-Card Scalability Path: The standard 4×5 block card includes pre-molded connection pins designed to accept up to two aftermarket field expansion cards, instantly upgrading the layout to a full 4-loop configuration.
  • Earth Fault Search Safety: Leverages automated, built-in control panel diagnostics to run background earth search sweeps down to 10k Ohms, preventing costly line noise issues in large industrial complexes.

Frequently Asked Questions (FAQ)

Q1: What does an active “No Answer” trouble code indicate when displayed on this card address?
A: A “No Answer” error on loop addresses 253 or 254 indicates that an expansion loop daughter card has been programmed into the master system software but cannot be detected physically on the motherboard pins.

Q2: Does the Simplex 4100-3109 Loop Card require a separate external power supply connection?
A: No. Power is supplied directly through the panel’s built-in Power Distribution Interface (PDI) connectors when the card is seated into an open block space inside the expansion bay chassis.

Q3: What is the maximum allowable wiring run distance to the farthest addressable loop device?
A: For loops populated with up to 125 active devices, the maximum wire length per run is 4,000 feet (1,219 meters). For higher loads between 126 and 250 devices, the distance is limited to 2,500 feet (762 meters).

Q4: Can this interface card communicate with older legacy devices on existing retrofit building circuits?
A: Yes, absolutely. The smart IDNet 2 protocol automatically manages communication loops containing a mix of modern TrueAlarm ES addressable components as well as legacy MAPNET II addressable devices.

Q5: What are the target loop capacitance parameters to prevent data drops on full runs?
A: The total channel wiring parameters require the sum of all line-to-line capacitance plus any line-to-shield capacitance across the isolated loops to not exceed 0.6 µF (600 nF).

Q6: How do on-board diagnostic LEDs behave when the module loses connection with the master panel CPU?
A: The dedicated COOMs trouble LED on the card will illuminate steady on if the card completely loses internal communication with the main fire panel processor board.

Q7: What is the primary manufacturing origin and casing profile of this replacement spare card?
A: This authentic life-safety system spare card is manufactured under strict fire safety guidelines in Mexico and features a standard 4×5 open circuit board block layout.

Reviews

There are no reviews yet.

Be the first to review “Simplex 4100-3109 Loop Card”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581