Description
Product Overview
What is this product? The NAFFCO NWR-120 is a heavy-duty, oblique-pattern 2-1/2″ Pressure Reducing Landing Valve engineered for Class I wet riser and internal fire hydrant systems.
How does it work? Installed on pressurized wet riser standpipes—particularly on lower floors of tall buildings where static and pump pressures are highest—the NWR-120 automatically throttles incoming pressures up to 20 bar down to a controlled outlet pressure range between 4 bar and 12 bar. Its integrated pressure-regulating mechanism maintains steady, safe discharge pressure at the 2-1/2″ female instantaneous outlet even when system pressure fluctuates.
Who needs this product? MEP contractors, fire protection engineers, high-rise developers, factory safety managers, and civil defense contractors designing or upgrading Class I wet riser installations.
Why is it useful in Bangladesh? Multi-story RMG garment factories, commercial high-rises, hospitals, and corporate towers in Dhaka, Gazipur, Chattogram, and Narayanganj operate high-head fire pumps that generate excessive pressure on lower-level hydrant landings. The NAFFCO NWR-120 ensures safe nozzle handling and meets strict BNBC, Fire Service & Civil Defence (FSCD), and international safety audit standards.
Key Features
-
BSI Kitemark Certified: Manufactured and certified to BS 5041 Part 1:1987 for high-pressure wet riser applications.
-
Integrated Pressure Regulation: Reduces inlet pressures up to 20 bar to a regulated outlet range of 4 bar to 12 bar.
-
Heavy-Duty Copper Alloy Body: Constructed from corrosion-resistant copper alloy to BS EN 1982 with a red-painted finish and black cast-iron handwheel.
-
Standard 2-1/2″ Instantaneous Outlet: Equipped with a female instantaneous coupling conforming to BS 336 and supplied with a tethered blank cap.
-
Under-Pressure Gland Maintenance: Engineered to allow gland seal replacement while under system pressure with the valve fully closed.
-
Tamper-Deterrent Security: Supplied complete with a strap and padlock to secure the handwheel against unauthorized operation.
Technical Advantages
-
Prevents Hose Whip & Nozzle Kickback: Eliminates excessive pressure at lower-floor wet riser outlets, ensuring safe manual firefighting operations.
-
High-Pressure Structural Integrity: Factory hydrostatically tested to 22 bar (valve seat) and 30 bar (body) for long-term leak-free reliability.
-
Replaceable Rubber Disc Facing: Features a renewable rubber disc facing (BS 1154) that simplifies maintenance and extends valve service life.
-
Reliable Flow Delivery: Delivers a minimum water flow rate of 8.5 L/s (510 LPM) at 4 bar outlet pressure for effective fire suppression.
Applications
-
High-Rise Commercial & Residential Towers: Lower and mid-level wet riser landings subject to high static head pressures.
-
RMG & Textile Factories: Multi-story garment manufacturing plants and dyeing complexes requiring Class I internal hydrant points.
-
Hospitals & Institutional Buildings: Healthcare complexes, universities, and shopping malls requiring BNBC and BS-compliant fire hydrant networks.
-
Industrial Warehouses & Logistics Hubs: Pressurized fire ring-main and standpipe installations.
Why Choose This Product?
-
Globally Trusted Brand: NAFFCO (UAE) is a premier international manufacturer of certified firefighting equipment across the Middle East and South Asia.
-
Full Compliance Assurance: BSI Kitemark approval under BS 5041-1 streamlines project sign-offs by FSCD inspectors and third-party safety auditors.
-
Built for Longevity: Copper alloy body, stainless/copper alloy stem, and replaceable seals withstand decades of pressurized standby service.
-
Local Supply & Support: Available in Bangladesh through loopshop.com.bd and Loop Engineering with technical documentation and project support.
4. Technical Specification Table
| Specification | Details |
| Model | NWR-120 |
| Brand | NAFFCO |
| Product Type | Oblique Pressure Reducing Landing Valve (Class I) |
| Valve Pattern | Oblique, Flanged Inlet |
| Inlet Connection | Flanged (BS 4504 Part 2:1974 Table 16/21) |
| Outlet Connection | 2-1/2″ Female Instantaneous Coupling (BS 336) |
| Maximum Working Pressure | 20 Bar (High-Pressure Rating) |
| Outlet Pressure Regulation Range | 4 Bar – 12 Bar |
| Test Pressure | Seat: 22 Bar / Body: 30 Bar |
| Minimum Water Flow Rate | 8.5 L/s at 4 Bar Outlet Pressure |
| Body & Bonnet Material | Copper Alloy to BS EN 1982 (Red Finish) |
| Handwheel Material | Grey Cast Iron to BS EN 1561 (Black Finish) |
| Certification & Standard | BSI Kitemark Approved, BS 5041-1:1987 |
| Included Accessories | Copper Alloy Blank Cap, Leather Strap & Non-Ferrous Padlock |
5. Features List
-
✓ BSI Kitemark certified to BS 5041-1:1987
-
✓ Rated for 20 bar maximum working pressure
-
✓ Regulates outlet pressure smoothly between 4 bar and 12 bar
-
✓ 2-1/2″ female instantaneous outlet to BS 336 with blank cap
-
✓ Heavy-duty copper alloy body (BS EN 1982) with red coating
-
✓ Gland seal replaceable under pressure when valve is closed
-
✓ Includes strap and padlock to prevent unauthorized tampering
6. Benefits For Customers
-
Protects Personnel & Equipment: Prevents over-pressurization of 2-1/2″ fire hoses, eliminating dangerous hose whip and burst risks on lower building floors.
-
Passes Fire Safety Audits: BSI Kitemark certification and BS 5041-1 compliance ensure smooth approval during BNBC, FSCD, and factory safety inspections.
-
Low Lifecycle Maintenance: Replaceable rubber disc facing and live-replaceable gland packing minimize system shutdowns during servicing.
-
Ready for Bangladesh High-Rises: Engineered to handle high-head fire pump systems common in Dhaka and Chattogram multi-story developments.
7. Installation & Maintenance Guide
Installation Requirements:
-
Mount the NWR-120 inside the designated wet riser landing cabinet at standard ergonomic height (typically 0.9m–1.1m above finished floor level) with adequate clearance for hose coupling and handwheel rotation.
-
Connect the flanged inlet securely to the wet riser branch pipe using rated high-pressure gaskets and bolts matching BS 4504 drilling.
-
Ensure the 2-1/2″ instantaneous outlet points downward at an oblique angle so connected fire hoses drape cleanly without kinking.
Maintenance Tips:
-
Inspect the blank cap, chain/tether, strap, and padlock monthly to ensure the outlet remains free of debris and unauthorized tampering.
-
Operate the handwheel periodically during scheduled maintenance to verify smooth stem travel and check the rubber disc facing for wear.
-
Flush and flow-test the landing valve annually using a calibrated pitot/pressure gauge to confirm outlet pressure stays within the 4–12 bar design window.
Safety Instructions:
-
Never remove the blank cap until the valve handwheel is confirmed fully closed and the riser pressure is verified.
-
If replacing the gland seal while the riser is pressurized, ensure the valve handwheel is fully closed and seated tightly before loosening the gland nut.
8. FAQ Section
Q: What is the price of NAFFCO Pressure Reducing Landing Valve NWR-120 in Bangladesh? A: The price of the NAFFCO NWR-120 2-1/2″ Pressure Reducing Landing Valve in Bangladesh depends on order quantity and current import costs. Visit loopshop.com.bd or request a commercial quote for exact BDT pricing.
Q: Where can I buy NAFFCO NWR-120 Landing Valve in Bangladesh? A: You can order genuine NAFFCO fire hydrant and wet riser valves online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, and nationwide.
Q: What warranty does this product have? A: The NAFFCO NWR-120 carries a manufacturer defect warranty backed by Loop Shop. Contact our team with your project BOQ for formal warranty documentation.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its corrosion-resistant copper alloy body and protective red enamel coating are specifically built to withstand high humidity and demanding industrial environments in Bangladesh.
Q: How to install this product? A: Bolt the flanged inlet onto the wet riser branch outlet inside the fire hydrant cabinet using a high-pressure gasket, and verify outlet pressure during hydrostatic commissioning.
Q: When is a Pressure Reducing Landing Valve required instead of a standard landing valve?A: A pressure reducing landing valve like the NWR-120 is required on lower floors of tall buildings or high-pressure hydrant networks where static/pump pressure exceeds safe hose-handling limits (typically above 7–8 bar), regulating it down to 4–12 bar.
Q: What outlet size and coupling standard does the NWR-120 use?A: It features a standard 2-1/2″ female instantaneous outlet compliant with BS 336, complete with a copper alloy blank cap.
Q: Is the NAFFCO NWR-120 certified for international fire audits?A: Yes, the NWR-120 is BSI Kitemark approved and manufactured in accordance with BS 5041 Part 1:1987.
Q: What is the maximum working pressure of the NAFFCO NWR-120?A: It is a high-pressure rated landing valve suitable for nominal inlet pressures up to 20 bar, with a body test pressure of 30 bar.

Reviews