NAFFCO Landing Valve 2-1/2″ (65 mm) Oblique, Flanged — Class I NDR 098KM — Kitemark

                    • Primary Purpose: Provides a reliable, high-flow water discharge point on wet riser fire hydrant systems for rapid firefighting hose deployment inside buildings.

                    • Key Specifications: Model NDR 098KM, oblique pattern with flanged inlet, 2-1/2″ (65 mm) BS 336 instantaneous female outlet with blank cap, 15 bar working pressure, and BSI Kitemark certification to BS 5041 Part 1.

                    • Customer Benefits: Heavy-duty copper alloy body resists corrosion, replaceable gland seal allows maintenance under line pressure, and included strap and padlock prevent unauthorized tampering.

                    • Bangladesh Market Relevance: Ideal for RMG textile factories, high-rise commercial towers, shopping malls, and industrial facilities across Bangladesh requiring BSI Kitemark and BNBC/NFPA-aligned fire hydrant compliance.

Best Price Guaranteed

Description

Product Overview

What is this product? The NAFFCO NDR 098KM is a heavy-duty, oblique-pattern flanged fire hydrant landing valve engineered for wet riser fire protection installations. It features a 2-1/2″ (65 mm) BS 336 instantaneous female outlet with a chain-retained blank cap and a bolted flanged inlet.

How does it work? Installed at each floor landing or hydrant cabinet along a permanently pressurized wet riser pipe, the valve isolates high-pressure firefighting water until an emergency occurs. When firefighters connect a 2-1/2″ (65 mm) fire hose coupling to the BS 336 instantaneous outlet and turn the grey cast iron handwheel, the oblique internal disc lifts to deliver a full-bore, low-turbulence water stream (8.5 L/s at 4 bar outlet pressure) directly to the fire hose.

Who needs this product? MEP contractors, fire protection engineers, RMG factory compliance teams, commercial building developers, and facility maintenance managers installing or upgrading indoor wet riser hydrant networks.

Why is it useful in Bangladesh? Industrial plants, garment factories, pharmaceutical facilities, and high-rise buildings in Dhaka, Gazipur, Chattogram, and Narayanganj face strict fire safety inspections from Fire Service & Civil Defence (FSCD), BNBC regulators, and international buyer audit bodies. The BSI Kitemark certified NAFFCO NDR 098KM guarantees verified British Standard compliance, long-term corrosion resistance in humid pump/riser rooms, and trouble-free audit approval.

Key Features

  • BSI Kitemark Certified: Independently certified by BSI under Kitemark (KM 87510) to BS 5041 Part 1 for wet riser landing valves.

  • Oblique Ergonomic Design: Angled valve body reduces friction loss and directs the hose downward naturally, preventing kinks at the outlet coupling.

  • 2-1/2″ (65 mm) BS 336 Instantaneous Outlet: Standard female quick-connect coupling with a matching copper alloy blank cap and stainless steel retaining chain.

  • Heavy-Duty Copper Alloy Body: Manufactured from EN 1982 copper alloy (gunmetal/bronze) for superior corrosion resistance against stagnant or treated fire-water.

  • Under-Pressure Gland Replacement: Engineered so the gland seal can be safely replaced while the riser remains pressurized and the valve is fully closed.

  • Anti-Tamper Strap & Padlock Included: Supplied with a heavy-duty strap and non-ferrous padlock to secure the black cast-iron handwheel against unauthorized operation.

Technical Advantages

  • Low Pressure Drop Performance: Oblique flow path delivers a minimum flow rate of 8.5 L/s at 4 bar outlet pressure for aggressive firefighting knockdown.

  • Replaceable Rubber Disc Facing: Renewable BS 1154 rubber disc seat ensures tight shutoff up to 16.5 bar seat test pressure and extends operational lifespan without replacing the entire valve.

  • High Structural Integrity: Hydrostatically body-tested to 22.5 bar with a 15 bar maximum working pressure rating.

  • Standardized Flanged Connection: Precision-drilled inlet flange to BS 4504 Part 2:1974 Table 16/21 for fast, leak-free bolted installation onto riser branch pipes.

Applications

  • RMG & Textile Factories: Multi-story garment production floors, fabric warehouses, and dyeing units requiring compliant internal hydrant points.

  • High-Rise Commercial & Residential Towers: Stairwell wet riser landings in offices, shopping malls, hotels, and apartment complexes.

  • Industrial & Manufacturing Plants: Pharmaceutical facilities, food processing units, and heavy engineering plants in EPZs and economic zones.

  • Fire Hydrant Cabinets: Inside single or double fire hose cabinets paired with 2-1/2″ layflat hoses and branch pipes/nozzles.

Why Choose This Product?

  • Globally Trusted Fire Brand: NAFFCO is a premier global manufacturer of certified fire fighting equipment trusted across major infrastructure projects.

  • Verified BSI Kitemark Quality: Eliminates audit rejections with authentic British Standard (BS 5041-1 & BS 336) certification.

  • Low Lifecycle Maintenance Cost: Replaceable rubber disc facing and under-pressure gland packing replacement minimize system downtime.

  • Local Supply & Engineering Support: Available in Bangladesh through loopshop.com.bd and Loop Engineering with technical documentation and nationwide delivery.

4. Technical Specification Table

Specification Details
Model NDR 098KM
Brand NAFFCO
Valve Type Oblique Pattern Landing Valve, Flanged Inlet
Pressure Class Class I / Low Pressure Valve (Up to 15 Bar)
Outlet Size & Type 2-1/2″ (65 mm) Female Instantaneous to BS 336:2010
Inlet Flange Drilling BS 4504 Part 2:1974 Table 16/21 (DN50 / 4 Holes Ø18 mm on 125 mm PCD)
Certification & Standard BSI Kitemark Certified (KM 87510) to BS 5041 Part 1:1987
Maximum Working Pressure 15 Bar
Hydrostatic Test Pressure Seat Test: 16.5 Bar | Body Test: 22.5 Bar
Minimum Water Flow Rate 8.5 L/s at 4 Bar Outlet Pressure
Body, Bonnet & Blank Cap Material Copper Alloy to EN 1982
Stem Material Copper Alloy to BS EN 12164
Handwheel Material Grey Cast Iron to BS EN 1561 (Black Painted)
Disc Facing & Seals Replaceable Rubber to BS 1154; Bonnet Seal: PTFE
Finish & Security Red Painted Body, Black Handwheel, Strap & Non-Ferrous Padlock Included

5. Features List

  • ✓ BSI Kitemark certified to BS 5041 Part 1 for wet riser systems

  • ✓ 2-1/2″ (65 mm) BS 336 female instantaneous outlet with chained blank cap

  • ✓ Oblique 45° body profile for smooth water flow and kink-free hose routing

  • ✓ Heavy-duty EN 1982 copper alloy construction with red protective finish

  • ✓ Rated for 15 bar working pressure (22.5 bar body test / 16.5 bar seat test)

  • ✓ Gland seal replaceable under pressure while valve is fully closed

  • ✓ Supplied with leather strap and non-ferrous padlock to prevent unauthorized use

6. Benefits For Customers

  • Passes Strict Fire Safety Audits: Genuine BSI Kitemark certification and BS 5041-1 compliance satisfy FSCD, BNBC, and international RMG buyer inspections.

  • Long-Term Corrosion Resistance: Copper alloy body and internal trim resist rust and mineral buildup in permanently charged wet risers.

  • Zero-Shutdown Seal Maintenance: Technicians can service the stem gland seal under full riser pressure without draining the building’s entire hydrant network.

  • Tamper-Proof Readiness: Included handwheel strap and padlock deter accidental opening while remaining easy for firefighters to release in emergencies.

7. Installation & Maintenance Guide

Installation Requirements:

  • Bolt the inlet flange onto the wet riser branch pipe using a full-face EPDM/neoprene flange gasket and appropriate grade bolts/nuts aligned to BS 4504 Table 16/21.

  • Position the valve inside the fire hydrant cabinet or stairwell landing at an ergonomic operating height (typically 900 mm to 1,200 mm above finished floor level) with the outlet angled downward for unobstructed hose coupling.

  • Ensure the copper alloy blank cap is securely locked into the 2-1/2″ BS 336 instantaneous lugs and tethered by its retaining chain.

Maintenance Tips:

  • Inspect the handwheel strap, padlock, and blank cap monthly to confirm the valve has not been tampered with or obstructed.

  • Operate the handwheel slightly during scheduled hydrant drills (with downstream isolation or drain control) and lubricate the copper alloy stem threads lightly to prevent seizing.

  • Check the BS 1154 rubber disc facing and instantaneous coupling lugs annually for wear, debris, or weeping.

Safety Instructions:

  • Never remove the blank cap while the valve is partially open or leaking under riser pressure.

  • Only perform gland seal replacement under pressure when the valve disc is verified 100% closed and seated, following standard fire system lockout/tagout protocols.

8. FAQ Section

Q: What is the price of NAFFCO NDR 098KM Landing Valve in Bangladesh? A: The price of the NAFFCO NDR 098KM 2-1/2″ (65 mm) Kitemark Oblique Flanged Landing Valve in Bangladesh depends on order quantity and current import batch rates. Contact loopshop.com.bd for an instant BDT quotation or bulk project pricing.

Q: Where can I buy NAFFCO NDR 098KM Landing Valve in Bangladesh? A: You can order genuine NAFFCO landing valves directly through loopshop.com.bd or Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.

Q: What warranty does this product have? A: This valve is backed by a manufacturer defect warranty supported by Loop Shop. Contact our engineering sales team for project-specific warranty documentation.

Q: Is this suitable for the Bangladesh climate? A: Yes. Built from marine-grade EN 1982 copper alloy with a protective red coating and corrosion-resistant internal seals, it thrives in humid stairwells and industrial riser rooms across Bangladesh.

Q: How to install this product? A: Bolt the flanged inlet to the wet riser branch outlet using an approved gasket and bolts, orienting the oblique 2-1/2″ BS 336 instantaneous outlet downward for easy fire hose attachment.

Q: What does “KM” in NDR 098KM stand for? A: “KM” indicates that this specific model is BSI Kitemark certified (Certificate No. KM 87510) to BS 5041 Part 1, distinguishing it from non-certified standard versions.

Q: What is the working and test pressure of the NAFFCO NDR 098KM? A: It is rated for a maximum working pressure of 15 bar, with a hydrostatic seat test pressure of 16.5 bar and a body test pressure of 22.5 bar.

Q: What type of hose connects to this landing valve? A: Any standard 2-1/2″ (65 mm) fire fighting hose fitted with a BS 336 male instantaneous coupling locks directly into the valve’s female instantaneous outlet.

Q: Can the gland seal be replaced without draining the wet riser? A: Yes. The NAFFCO NDR 098KM is specifically engineered so the gland seal can be safely replaced under riser pressure when the valve is fully closed.

Q: Does this landing valve include a blank cap and padlock? A: Yes, it comes complete with a copper alloy BS 336 blank cap on a retaining chain plus a strap and non-ferrous padlock for handwheel security.

riser connections.

Reviews

There are no reviews yet.

Be the first to review “NAFFCO Landing Valve 2-1/2″ (65 mm) Oblique, Flanged — Class I NDR 098KM — Kitemark”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581