Description
Product Overview
What is this product?The Shield 80 mm (3″) UL/FM Sprinkler Zone Control Valve Set is a complete, pre-engineered wet sprinkler riser assembly manufactured by Shield (UK). It integrates an 80 mm (3″) supervised butterfly isolation valve, a paddle-type water flow detector switch, a pressure gauge, and a Shield Model SD-TDV50T Test and Drain Valve with sight glass into one unified zone control station.
How does it work? Installed at the branch connection serving a specific floor or fire zone, the assembly keeps the sprinkler network pressurized and monitored. When a sprinkler head activates—or when an engineer opens the SD-TDV50T test and drain valve to simulate a single sprinkler flow—the water flow switch detects the movement and sends an immediate alarm signal to the Fire Alarm Control Panel (FACP). If the isolation butterfly valve is closed for maintenance, its built-in supervisory tamper switch alerts the panel so a zone is never left accidentally shut off.
Who needs this product? Fire protection contractors, MEP engineers, factory compliance managers, and commercial building owners installing or upgrading multi-zone automatic wet sprinkler systems.
Why is it useful in Bangladesh? Multi-story RMG textile factories, spinning mills, pharmaceutical plants, and commercial towers in Dhaka, Gazipur, Chattogram, and Narayanganj must meet strict NFPA 13, BNBC, and international fire safety audit standards. Using a certified UL/FM Shield Zone Control Valve Set simplifies periodic NFPA 25 flow testing and allows localized maintenance on a single production floor without compromising fire safety across the rest of the facility.
Key Features
-
Complete Zone Control Assembly: Combines isolation, flow detection, pressure monitoring, and test/drain functions in a compact 80 mm (3″) station.
-
UL Listed & FM Approved Components: Certified to international fire protection standards for seamless audit and regulatory approval.
-
Integrated SD-TDV50T Test & Drain Valve: Forged brass body with chrome-plated brass ball, PTFE seats, 3-position single handle (Off / Test / Drain), tamper-resistant test orifice, and built-in sight glass.
-
Supervised Butterfly Isolation Valve: Gear-operated 80 mm (3″) butterfly valve with visual position flag and integrated tamper switch for continuous FACP supervision.
-
Instant Water Flow Detection: UL/FM vane-type water flow switch with adjustable pneumatic retard to prevent false alarms caused by water pressure surges.
-
System Pressure Monitoring: Includes a UL/FM listed sprinkler pressure gauge for quick visual verification of zone line pressure.
Technical Advantages
-
Zero Whole-Building Shutdowns: Isolates and drains a single 3-inch sprinkler zone for head replacement or pipe modification while keeping all other floors active.
-
Visual Flow Verification: The SD-TDV50T sight glass allows inspectors to visually confirm water discharge during routine weekly or quarterly flow tests.
-
Surge-Protected Alarm Signaling: Built-in retard mechanism on the flow switch eliminates nuisance alarms from municipal or pump pressure fluctuations.
-
Heavy-Duty Industrial Durability: Ductile iron valve bodies with corrosion-resistant epoxy coating and forged brass test/drain trim ensure long service life.
Applications
-
RMG & Textile Factories: Floor-by-floor sprinkler zone control in sewing, cutting, dyeing, and finished goods warehouses.
-
Commercial High-Rises: Office towers, shopping malls, hotels, and residential apartments requiring zoned wet sprinkler risers.
-
Pharmaceutical & Industrial Plants: Cleanrooms, packaging halls, and logistics hubs in EPZs and industrial corridors.
-
Fire Safety Upgrades: Retrofitting non-zoned sprinkler risers to meet NFPA 13 and insurance compliance mandates.
Why Choose This Product?
-
Trusted UK Fire Engineering: Shield (UK) is globally recognized for reliable, code-compliant water-based fire protection valves and fittings.
-
Audit-Ready Documentation: Supplied with UL Listing and FM Approval references required by fire safety consultants and inspectors.
-
Streamlined Installation: All matching components are engineered to work together, reducing installation labor and leak points.
-
Backed by Loop Shop Bangladesh: Supplied with technical selection support, BOQ matching, and nationwide delivery through Loop Engineering & Loop Shop.
4. Technical Specification Table
| Specification | Details |
| Product Name | Sprinkler Zone Control Valve Set 80 mm (3″) |
| Brand & Origin | Shield, UK |
| Test & Drain Valve Model | SD-TDV50T (Threaded NPT, 3-Position Ball Valve with Sight Glass) |
| Nominal Zone Size | 80 mm (3 Inch) |
| Certifications | UL Listed & FM Approved |
| Compliance Standards | NFPA 13, NFPA 13R, NFPA 13D, NFPA 25 |
| Main Isolation Valve | 80 mm (3″) Supervised Butterfly Valve with Tamper Switch (300 PSI Rated) |
| Flow Detection | UL/FM Vane-Type Water Flow Alarm Switch with Retard Timer |
| Pressure Monitoring | UL/FM Listed Sprinkler Pressure Gauge (PSI / Bar) |
| Test & Drain Construction | Forged Brass Body, Chrome-Plated Brass Ball, PTFE Seats, Sight Glass |
| Connection Type | Grooved / Wafer Main Line with Threaded (NPT) Test & Drain Assembly |
| Application System | Automatic Wet Pipe Fire Sprinkler Systems |
5. Features List
-
✓ Complete 80 mm (3″) wet sprinkler zone control assembly
-
✓ Genuine Shield (UK) UL Listed & FM Approved components
-
✓ Includes Shield SD-TDV50T forged brass Test & Drain Valve with sight glass
-
✓ 3-position ball valve handle (Off, Test, Drain) with tamper-resistant test orifice
-
✓ Supervised 3″ butterfly valve with dual tamper switches and position indicator
-
✓ Vane-type water flow switch for immediate Fire Alarm Control Panel notification
-
✓ Integrated pressure gauge for instant zone pressure checks
6. Benefits For Customers
-
Uninterrupted Facility Protection: Lets maintenance teams drain and repair one 3″ sprinkler zone without disabling fire protection across other factory floors.
-
Fast & Clean Periodic Testing: Built-in SD-TDV50T test orifice and sight glass allow technicians to verify water flow alarms safely in minutes.
-
Prevents Accidental Valve Closure: Supervisory tamper switches immediately alert building security if anyone closes the zone butterfly valve.
-
Full Fire Audit Approval: UL/FM certification satisfies strict compliance requirements for RMG factories, commercial towers, and industrial plants in Bangladesh.
7. Installation & Maintenance Guide
Installation Requirements:
-
Flush the main sprinkler riser piping thoroughly before installing the 80 mm (3″) zone control assembly to prevent debris from damaging valve seats or obstructing the flow switch paddle.
-
Install the butterfly valve with the visual position flag clearly visible and wire the supervisory tamper switches and water flow switch to a dedicated addressable monitor module on the Fire Alarm Control Panel.
-
Pipe the outlet of the SD-TDV50T test and drain valve to an open drainage line capable of handling full 3″ zone drain discharge.
Maintenance Tips:
-
Perform quarterly water flow alarm tests by turning the SD-TDV50T handle to the TEST position and verifying both visual flow through the sight glass and alarm activation at the FACP.
-
Inspect the butterfly valve position indicator weekly to confirm the valve remains fully open and locked/supervised.
-
Check the pressure gauge reading regularly and inspect the sight glass for scale buildup or cloudiness.
Safety Instructions:
-
Always notify the building safety officer, fire command center, and monitoring station before conducting flow tests or closing the zone isolation valve.
-
Return the SD-TDV50T handle firmly to the OFF position after testing and verify that the butterfly valve is fully open before restoring the system to normal service.
8. FAQ Section
Q: What is the price of Shield Sprinkler Zone Control Valve Set 80 mm (3″) SD-TDV50T in Bangladesh? A: The price depends on project quantity, connection configuration (grooved or wafer), and current import rates. Contact loopshop.com.bd directly for an exact BDT quotation and bulk project pricing.
Q: Where can I buy Shield 80 mm (3″) Sprinkler Zone Control Valve Set in Bangladesh? A: You can order genuine Shield (UK) UL/FM sprinkler zone control valve sets through loopshop.com.bd or Loop Engineering, with delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.
Q: What warranty does this product have? A: It includes a standard manufacturer warranty against manufacturing defects, backed by local technical support from Loop Shop Bangladesh.
Q: Is this suitable for the Bangladesh climate? A: Yes. The epoxy-coated ductile iron valves and forged brass SD-TDV50T test and drain assembly are engineered to resist corrosion in humid pump rooms and factory utility shafts across Bangladesh.
Q: How to install this product?A: Mount the 80 mm (3″) butterfly valve, flow switch, pressure gauge, and SD-TDV50T test/drain assembly in sequence on the zone branch line, connect the supervisory and flow switches to the fire alarm panel, and route the drain line to an open floor drain.
Q: What components are included in a complete 80 mm (3″) Zone Control Valve Set?A: A complete set includes the 80 mm (3″) supervised butterfly valve, water flow detector switch, pressure gauge, and the Shield SD-TDV50T Test and Drain Valve with sight glass.
Q: What does the SD-TDV50T model number refer to?A: SD-TDV50T is Shield’s threaded NPT Test and Drain Valve featuring a 3-position ball valve (Off/Test/Drain), tamper-resistant K-factor test orifice, and integrated sight glass.
Q: Are the valves UL Listed and FM Approved for factory audits? A: Yes. The Shield zone control components carry UL Listing and FM Approval, and datasheets/listing references can be provided for NFPA 13 and industrial safety audits.
Q: Why is a supervisory switch needed on the butterfly valve? A: Under NFPA 13 and NFPA 25, every sprinkler control valve must be electrically supervised so the fire alarm panel immediately registers a trouble/supervisory signal if the valve is partially or fully closed.
Q: What K-factor test orifice does the test and drain valve use? A: The test orifice is sized to simulate the discharge of a single sprinkler head (commonly K5.6 for standard hazard zones) to verify water flow switch activation without flooding the facility

Reviews
There are no reviews yet.