Description
Product Overview
What is this product? The 2-Way Fire Brigade Connection (commonly known as a Breeching Inlet) is an exterior building fire-fighting intake manifold equipped with two 2.5-inch inlet couplings, internal check valves, and a 4-inch main discharge outlet connected to the building’s fire suppression riser.
How does it work? During a fire emergency, if the building’s internal fire pump fails or the on-site water reservoir runs low, Bangladesh Fire Service & Civil Defence (FSCD) personnel connect their fire truck hoses to the dual 2.5-inch inlets. Water enters through the spring-loaded non-return check valves—which open under incoming pump pressure and close automatically to prevent backflow—boosting pressure throughout the internal hydrant and sprinkler piping.
Who needs this product? MEP contractors, fire protection engineers, real estate developers, factory owners, and facility managers constructing or upgrading multi-story buildings and industrial facilities.
Why is it useful in Bangladesh? Under the Bangladesh National Building Code (BNBC) and Fire Service & Civil Defence (FSCD) regulations, multi-story commercial buildings, shopping malls, hospitals, and RMG factories require accessible exterior fire brigade connections. This heavy-duty Non-UL 2-way breeching inlet delivers dependable emergency water injection at a cost-effective price point for non-UL-mandated projects.
Key Features
-
Dual 2.5″ Inlet Connections: Allows two fire brigade delivery hoses to pump water simultaneously into the building’s fire main for maximum flow capacity.
-
Integrated Non-Return Check Valves: Individual spring-loaded check valves on each inlet prevent pressurized system water from escaping when only one hose is connected or disconnected.
-
4-Inch Main Outlet: Standard 4″ flanged (BS/ANSI) or grooved connection seamlessly integrates with main vertical dry/wet risers and sprinkler headers.
-
Automatic Drain Valve: Built-in 1″ drain valve automatically empties residual water inside the inlet body after use, preventing stagnation and corrosion.
-
Protective Dust Caps & Chains: Includes heavy-duty blanking caps secured with chains to keep dirt, insects, and debris out of the couplings.
-
High-Visibility Red Finish: Coated in durable red epoxy/enamel paint for instant recognition by firefighters and compliance with fire safety marking standards.
Technical Advantages
-
Heavy-Duty Cast Iron / Ductile Iron Body: Engineered to withstand high operating pressures and rugged outdoor environmental exposure.
-
Copper Alloy / Brass Couplings & Internals: Corrosion-resistant inlet adapters and check valve seats ensure smooth hose coupling without seizing over long periods of inactivity.
-
Zero Backflow Leakage: Precision-machined check valve seals maintain system pressure integrity during both static standby and active pumping.
-
Wall-Mounted or Cabinet-Ready Design: Compatible with flush-mounted or surface-mounted breeching inlet boxes with wired-glass inspection doors.
Applications
-
High-Rise Commercial & Residential Buildings: External fire brigade intake for dry risers, wet risers, and basement sprinkler networks.
-
RMG & Textile Factories: Perimeter fire hydrant ring mains and factory building standpipe systems across Gazipur, Savar, Ashulia, and Narayanganj.
-
Warehouses & Logistics Hubs: Rapid water supply boost for large-span storage facilities.
-
Hospitals, Hotels & Shopping Malls: Mandatory emergency fire department connection points along building perimeters and fire access roads.
Why Choose This Product?
-
Code-Aligned Functionality: Meets FSCD and BNBC functional requirements for emergency fire brigade water supplementation.
-
Cost-Effective Reliability: Ideal for local commercial, residential, and industrial projects where Non-UL listed equipment meets project specifications without compromising mechanical durability.
-
Complete Ready-to-Install Assembly: Supplied complete with inlet couplings, check valves, drain valve, and protective caps.
-
Trusted Supply via Loop Shop: Backed by engineering consultation, compatibility verification, and fast nationwide delivery from Loop Engineering & Loop Shop.
4. Technical Specification Table
| Specification | Details |
| Product Name | 2-Way Fire Brigade Connection (Breeching Inlet) |
| Certification Grade | Non-UL (Standard Industrial / BS-Aligned Design) |
| Inlet Configuration | 2 x 2.5 Inch (65 mm) Instantaneous / Threaded Inlets |
| Outlet Size | 4 Inch (100 mm) Flanged / Grooved Outlet |
| Body Material | Heavy-Duty Cast Iron / Ductile Iron |
| Coupling & Valve Trim Material | Copper Alloy / Brass |
| Check Valve Type | Dual Integrated Spring-Loaded Non-Return Check Valves |
| Drain Connection | Built-in Automatic Drain Valve |
| Working Pressure | Up to 16 Bar (232 PSI) |
| Test Pressure | 24 Bar (348 PSI) |
| Surface Finish | Fire Red Epoxy / Enamel Coating |
| Accessories Included | 2 x Protective Blanking Caps with Retaining Chains |
5. Features List
-
✓ Dual 2.5-inch fire brigade hose inlets for high-volume water intake
-
✓ 4-inch standard flanged/grooved outlet for main riser connection
-
✓ Individual spring-loaded non-return check valves on both inlets
-
✓ Built-in automatic drain valve to prevent stagnant water buildup
-
✓ Heavy-duty cast/ductile iron body with corrosion-resistant red finish
-
✓ Brass/copper alloy couplings with protective dust caps and chains
-
✓ Suitable for wet risers, dry risers, hydrant mains, and sprinkler systems
6. Benefits For Customers
-
Uninterrupted Firefighting Water Supply: Enables the Fire Service to directly pressurize internal fire mains even during power outages or fire pump failure.
-
Prevents Reverse Flow Hazards: Dual independent check valves allow firefighters to connect or disconnect one hose line without losing pressure from the second line.
-
Long Outdoor Service Life: Weather-resistant red coating, brass couplings, and protective caps prevent rust and thread seizure in Bangladesh’s humid monsoon climate.
-
Budget-Friendly Project Compliance: Provides reliable, heavy-duty performance for commercial and industrial buildings in Bangladesh without the higher cost of UL/FM imports.
7. Installation & Maintenance Guide
Installation Requirements:
-
Mount the 2-way breeching inlet on an exterior building wall facing a fire engine access road at a recommended height of 750 mm to 1,200 mm above finished ground level.
-
Ensure unobstructed clearance in front of the inlets so fire brigade personnel can easily attach 2.5″ hoses.
-
Connect the 4″ outlet securely to the building’s fire riser header using rated gaskets and bolts, and install an isolation/drain assembly inside the building as required by project drawings.
Maintenance Tips:
-
Inspect the protective caps, chains, and rubber coupling washers every 6 months to ensure they are intact and free of debris.
-
Exercise and verify smooth movement of the internal check valve clappers and automatic drain valve during annual fire hydrant system testing.
-
Touch up any chipped red paint on the exterior housing to prevent surface rust during monsoon seasons.
Safety Instructions:
-
Never block, lock with unauthorized padlocks, or obstruct the breeching inlet with signage, parked vehicles, or landscaping.
-
Ensure proper identification signage (“FIRE BRIGADE INLET” / “SPRINKLER BREECHING INLET”) is permanently mounted directly above the unit.
8. FAQ Section
Q: What is the price of a 2-Way Fire Brigade Connection (Breeching Inlet) in Bangladesh? A: The price of a Non-UL 2-Way Fire Brigade Connection in Bangladesh depends on flange standard, coupling type, and order volume. Visit loopshop.com.bd or contact our team for a quick BDT quotation.
Q: Where can I buy a 2-Way Breeching Inlet in Bangladesh? A: You can order 2-way fire brigade connections online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all over Bangladesh.
Q: What warranty does this product have? A: This product carries a manufacturer defect warranty backed by Loop Shop. Contact our sales engineers for full warranty details tailored to your project order.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its heavy-duty cast iron body, corrosion-resistant red protective finish, brass couplings, and protective blanking caps are built to withstand Bangladesh’s heavy monsoon rains, high humidity, and dust.
Q: How to install this product? A: Mount the breeching inlet horizontally or vertically (per model orientation) on an accessible exterior wall 750 mm–1,200 mm above ground, and bolt the 4″ flanged outlet directly to the fire riser pipework.
Q: What is the difference between a 2-way and a 4-way breeching inlet? A: A 2-way breeching inlet features two 2.5″ inlets feeding a 4″ outlet (standard for single-riser commercial and mid-sized industrial buildings), whereas a 4-way breeching inlet has four 2.5″ inlets feeding a 6″ outlet for larger high-rise or high-hazard complexes.
Q: Does this unit include non-return check valves? A: Yes, each 2.5″ inlet is equipped with an integrated spring-loaded non-return check valve to prevent water backflow when pressurizing the system.
Q: Is this product UL Listed? A: No, this is a Non-UL standard industrial model ideal for local commercial, residential, and factory projects governed by BNBC and FSCD requirements where UL certification is not mandatory.
Q: Can it be used for both wet risers and dry risers? A: Yes, this 2-way fire brigade connection is compatible with dry risers, wet risers, fire hydrant ring mains, and automatic sprinkler systems.
Q: Are breeching inlet cabinets also available? A: Yes, flush-mounted and surface-mounted red steel breeching inlet boxes with wired glass doors are available separately or as a complete set via loopshop.com.bd.

Reviews
There are no reviews yet.