NAFFCO 2-Way Fire Brigade Connection (Breeching Inlet) NDR095 — Kitemark

    • Primary Purpose: Provides an external twin-inlet water supply point allowing municipal fire brigade tenders to pump pressurized water directly into dry or wet fire hydrant risers.

    • Key Specifications: Model NDR095, 2-way inlet configuration, BSI Kitemark certified to BS 5041 Part 3, equipped with dual instantaneous male inlets, non-return check valves, and a 4-inch flanged outlet.

    • Customer Benefits: Ensures uninterrupted high-volume firefighting water delivery during power failures or main tank depletion while preventing dangerous backflow.

    • Bangladesh Market Relevance: Essential for high-rise commercial towers, RMG textile factories, and industrial complexes across Dhaka, Gazipur, and Chattogram requiring BNBC and Fire Service & Civil Defence (FSCD) compliance.

Best Price Guaranteed

Description

Product Overview

What is this product? The NAFFCO NDR095 is a heavy-duty, 2-way fire brigade breeching inlet (Siamese/fire department connection) certified with the BSI Kitemark. It serves as the primary external charging interface between fire department pumper trucks and a building’s internal dry or wet standpipe riser system.

How does it work? Mounted on the exterior wall or boundary enclosure of a building at street level, the NAFFCO NDR095 features two 2.5-inch instantaneous male inlets fitted with internal spring-loaded non-return (check) valves and protective blank caps with chains. When fire brigade personnel connect their delivery hoses and pump water into the inlets, the internal check valves open to feed the 4-inch outlet riser—and automatically close when pumping stops or if only one hose line is pressurized, preventing backflow and pressure loss.

Who needs this product? MEP contractors, fire protection engineers, industrial factory owners, commercial real estate developers, and facility managers installing or upgrading building fire hydrant and dry riser networks.

Why is it useful in Bangladesh? Under the Bangladesh National Building Code (BNBC) and Bangladesh Fire Service & Civil Defence (FSCD) regulations, multi-story buildings, garment factories, and industrial warehouses must provide accessible external fire brigade connections. The BSI Kitemark certification on the NAFFCO NDR095 guarantees smooth inspection clearance for local compliance as well as international factory safety audits.

Key Features

  • BSI Kitemark Certified: Independently tested and certified to BS 5041 Part 3 standards for inlet breeching assemblies.

  • Dual 2.5-Inch Instantaneous Male Inlets: Manufactured to BS 336 specifications for rapid, leak-tight coupling with standard fire brigade delivery hoses.

  • Integrated Non-Return Check Valves: Individual spring-loaded check valves on each inlet prevent back-pressure and allow single-hose or dual-hose operation.

  • 4-Inch Flanged Outlet Connection: Standard flanged discharge port (BS 4504 PN16 / ANSI compatible) for direct integration into main vertical riser piping.

  • Automatic Drain Valve Provision: Includes a 1-inch drain valve port to empty residual water from dry risers after firefighting or hydrostatic testing.

  • Protective Blank Caps & Chains: Supplied with durable plastic/metal dust caps secured by chains to keep debris, insects, and moisture out of the couplings.

  • Corrosion-Resistant Finish: Heavy-duty cast/ductile iron body with red epoxy/polyester powder-coated exterior and copper-alloy internal trim.

Technical Advantages

  • Backflow & Pressure Isolation: Dual independent check valves ensure that charging one inlet does not blow water out of the second inlet if only one pump line is connected.

  • Rapid Emergency Deployment: Instantaneous push-fit male couplings enable firefighters to establish water supply in seconds rather than threading slow screw couplings.

  • High-Pressure Structural Integrity: Engineered to withstand high-pressure fire tender pumping surges without flange distortion or seal failure.

  • Low Maintenance Lifecycle: Corrosion-protected wetted trim and sealed blank caps prevent seizing during long periods of standby readiness.

Applications

  • Industrial & RMG Factories: External perimeter walls of textile mills, spinning units, dyeing factories, and export-oriented warehouses.

  • Commercial High-Rise Buildings: Ground-level street facades of corporate towers, shopping malls, hotels, and mixed-use complexes.

  • Residential Towers: Multi-story apartment buildings equipped with dry or wet fire hydrant risers.

  • Institutional & Infrastructure Projects: Hospitals, universities, power substations, and municipal utility buildings.

Why Choose This Product?

  • Globally Recognized Certification: BSI Kitemark approval eliminates compliance risks during FSCD, BNBC, and third-party industrial fire audits.

  • Proven NAFFCO Engineering: Manufactured by one of the world’s leading firefighting equipment producers with strict quality control.

  • Reliable Field Performance: Smooth check-valve actuation and precision-machined BS 336 couplings ensure zero delays during real emergencies.

  • Trusted Local Supply: Available in Bangladesh through loopshop.com.bd with technical specification support and nationwide delivery.

4. Technical Specification Table

Specification Details
Model NDR095
Brand NAFFCO
Product Type 2-Way Breeching Inlet (Fire Brigade Connection)
Certification BSI Kitemark Certified (BS 5041 Part 3)
Inlet Configuration 2 x 2.5″ Instantaneous Male Couplings (BS 336)
Outlet Size 4″ (100 mm) Flanged Connection
Check Valve Mechanism Dual Built-In Spring-Loaded Non-Return Valves
Body Material Heavy-Duty Cast / Ductile Iron
Trim & Coupling Material Copper Alloy / Gunmetal / Brass
Drain Connection 1″ Drain Valve Included
Surface Finish Red Corrosion-Resistant Powder / Epoxy Coating
Accessories Included 2 x Protective Blank Caps with Securing Chains

5. Features List

  • ✓ BSI Kitemark certified to BS 5041 Part 3

  • ✓ Dual 2.5″ BS 336 instantaneous male inlets

  • ✓ Built-in individual non-return check valves

  • ✓ Standard 4″ flanged outlet for dry/wet risers

  • ✓ Integrated 1″ drain valve for riser emptying

  • ✓ Protective blank caps with chains included

  • ✓ Corrosion-resistant red epoxy-coated iron body

6. Benefits For Customers

  • Passes Fire Safety Audits Easily: Genuine BSI Kitemark certification satisfies BNBC, FSCD, and international buyer compliance requirements in Bangladesh.

  • Saves Critical Response Time: Instantaneous couplings allow fire brigade crews to connect hoses immediately upon arrival.

  • Prevents Riser Corrosion & Freezing: Built-in drain valve allows complete dewatering of dry risers after pressure testing.

  • Long-Term Outdoor Durability: Heavy-duty epoxy finish and protective caps withstand Bangladesh’s monsoon humidity, dust, and coastal air.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the breeching inlet horizontally or vertically (as per system layout) on an exterior building wall or dedicated red-painted cabinet at an accessible height (typically 750 mm to 1,000 mm above finished ground level) facing the fire engine access road.

  • Bolt the 4-inch flanged outlet securely to the riser feed pipe using a full-face rubber gasket and high-tensile flange bolts.

  • Connect the 1-inch drain valve outlet to a suitable drainage point to prevent water pooling around the building foundation.

Maintenance Tips:

  • Inspect the instantaneous male couplings and rubber sealing washers every 6 months for dirt, oxidation, or wear.

  • Manually depress the internal spring-loaded check valve clappers during routine inspections to ensure smooth movement without sticking.

  • Verify that both protective blank caps and retaining chains remain intact and securely fitted.

Safety Instructions:

  • Keep the area directly in front of the breeching inlet completely unobstructed (minimum 1.5 meters clearance) at all times for fire brigade access.

  • Ensure clear, permanent signage reading “DRY RISER INLET” or “FIRE BRIGADE CONNECTION” is mounted immediately above the unit.

  • Depressurize the riser system completely via the drain valve before unbolting flanges or servicing check valves.

8. FAQ Section

Q: What is the price of NAFFCO NDR095 2-Way Breeching Inlet in Bangladesh? A: The price of the NAFFCO NDR095 Kitemark 2-Way Breeching Inlet in Bangladesh depends on current import tariffs and order volume. Contact loopshop.com.bd for the latest BDT price or project quotation.

Q: Where can I buy NAFFCO NDR095 Breeching Inlet in Bangladesh? A: You can order genuine NAFFCO NDR095 breeching inlets online at loopshop.com.bd or through Loop Engineering, with fast delivery to Dhaka, Gazipur, Chattogram, Narayanganj, and across Bangladesh.

Q: What warranty does this product have? A: The NAFFCO NDR095 carries a standard manufacturer warranty against material and casting defects, supported locally by Loop Shop.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its corrosion-resistant red powder-coated cast iron body, copper-alloy couplings, and protective blank caps are built to withstand heavy monsoon rain, high humidity, and dusty industrial environments in Bangladesh.

Q: How to install this product? A: Mount the unit on an exterior wall accessible to fire trucks at roughly 0.75–1.0 meter above ground, bolt the 4-inch flanged outlet to the riser pipe with a proper gasket, and connect the 1-inch drain valve.

Q: What certification does the NAFFCO NDR095 carry? A: It is BSI Kitemark certified under BS 5041 Part 3, with 2.5-inch instantaneous couplings manufactured to BS 336 standards.

Q: Can this breeching inlet be used for both dry risers and wet risers? A: Yes, the NAFFCO NDR095 2-way breeching inlet is engineered for both dry riser systems and wet hydrant/sprinkler booster connections.

Q: What happens if the fire brigade only connects one hose instead of two? A: Each 2.5-inch inlet has its own independent non-return check valve, so water pumped into one inlet will not escape through the unused second inlet.

Q: Does the NAFFCO NDR095 include blank caps and a drain valve? A: Yes, it comes complete with two protective blank caps on retaining chains and a 1-inch drain valve.

Q: Is this accepted by Bangladesh Fire Service & Civil Defence (FSCD)? A: Yes, Kitemark-certified NAFFCO breeching inlets meet BNBC and FSCD standards for commercial and industrial fire hydrant installations in Bangladesh.

Reviews

There are no reviews yet.

Be the first to review “NAFFCO 2-Way Fire Brigade Connection (Breeching Inlet) NDR095 — Kitemark”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581