4-Way Fire Brigade Connection (Breeching Inlet) (EM / AE or equivalent) — Kitemark

                • Primary Purpose: Connects fire brigade pumper trucks directly to building dry or wet riser mains and sprinkler networks for rapid external firefighting water supply.

                • Key Specifications: 4 × 2.5″ (65mm) BS 336 male instantaneous inlets with spring-loaded non-return valves, 150mm (6″) flanged outlet, 1″ drain valve, and BSI Kitemark certification to BS 5041 Part 3.

                • Customer Benefits: Prevents backflow across individual inlets, allows fast multi-hose connection during emergencies, and simplifies post-incident line draining.

                • Bangladesh Market Relevance: Engineered for high-rise commercial towers, RMG textile factories, and industrial facilities across Bangladesh requiring FSCD, BNBC, and international fire audit compliance.

Best Price Guaranteed

Description

Product Overview

What is this product?The EM / AE (or equivalent BSI Kitemark certified) 4-Way Fire Brigade Connection—commonly known as a 4-Way Breeching Inlet—is a heavy-duty fire hydrant manifold assembly. It features four 2.5-inch instantaneous male inlet couplings feeding into a single 150mm (6-inch) flanged riser outlet, complete with an integrated drain valve.

How does it work?Installed at fire brigade access level on the exterior wall or inside a dedicated breeching inlet cabinet, the unit remains closed under normal conditions. During a fire emergency, firefighters couple up to four delivery hoses from fire tenders onto the BS 336 male instantaneous inlets. Internal spring-loaded mushroom-type non-return valves (NRVs) open under pump pressure to charge the building’s 150mm dry riser or sprinkler main while automatically sealing unused inlets against backflow. After firefighting operations conclude, the built-in 1-inch drain valve safely empties residual water from the riser.

Who needs this product? Fire protection contractors, MEP engineers, industrial factory owners, and high-rise commercial property developers constructing or upgrading compliant fire hydrant and dry riser systems.

Why is it useful in Bangladesh? Rapidly urbanizing high-rises in Dhaka and Chattogram, alongside export-oriented RMG factories and industrial plants in Gazipur, Narayanganj, and Savar, must pass strict Fire Service & Civil Defence (FSCD), BNBC, and international buyer safety audits. A BSI Kitemark-certified 4-way breeching inlet guarantees standardized coupling compatibility with fire brigade hoses and verified pressure integrity.

Key Features

  • BSI Kitemark Certified (BS 5041 Part 3): Independently verified for manufacturing quality, dimensional accuracy, and pressure safety in fire hydrant riser systems.

  • Four BS 336 Male Instantaneous Inlets: Standard 2.5-inch (65mm) copper alloy couplings enable simultaneous high-volume water injection from multiple fire brigade hoses.

  • Individual Spring-Loaded Non-Return Valves: Each inlet features an integrated copper alloy check valve so hoses can be connected or disconnected independently without losing system pressure.

  • 150mm (6″) Flanged Main Outlet: Heavy-duty flanged discharge port connects directly to 6-inch vertical riser piping.

  • Integrated 1″ Drain Valve & Blank Caps: Includes a BS 5154 compliant drain valve for system maintenance plus protective blank caps with chains to keep inlets free of dust and debris.

  • Corrosion-Resistant Ductile Iron & Copper Alloy Build: Spheroidal graphite cast iron (ductile iron) manifold finished in high-visibility red coating paired with durable copper alloy internals.

Technical Advantages

  • High Flow Capacity: Four parallel 2.5-inch inlets maximize water delivery volume into 150mm dry riser and sprinkler mains during major fire events.

  • Zero Backflow Risk: Precision-machined copper alloy non-return valves prevent pressurized water from escaping through uncoupled inlets.

  • Rugged Structural Integrity: Ductile iron body construction resists mechanical impact and high-pressure surges up to test ratings.

  • Low Maintenance Longevity: Protective inlet caps and corrosion-resistant internal trim ensure smooth valve actuation even after years of standby exposure.

Applications

  • Commercial High-Rises: Office towers, shopping complexes, and hotels requiring 150mm dry or wet riser fire brigade connections.

  • Industrial & RMG Factories: Garment factories, textile mills, chemical plants, and warehouses in Bangladesh’s industrial zones.

  • Healthcare & Institutional Facilities: Hospitals, universities, and government buildings.

  • Infrastructure & Mega Projects: Underground parking structures, airports, and utility installations.

Why Choose This Product?

  • Audit-Ready Certification: Genuine BSI Kitemark approval eliminates compliance delays during FSCD and third-party fire safety inspections.

  • Universal Brigade Compatibility: Manufactured to BS 336 instantaneous coupling standards used by municipal and industrial fire services.

  • Proven Engineering Brands: Supplied in trusted EM / AE or equivalent certified specifications for dependable long-term service.

  • Dedicated Supply via Loop Shop: Backed by technical verification, compliance documentation, and nationwide delivery across Bangladesh through Loop Engineering & Loop Shop.

4. Technical Specification Table

Specification Details
Brand EM / AE (or Equivalent Certified)
Model 4-Way Fire Brigade Breeching Inlet (BS 5041-3)
Certification BSI Kitemark Certified (BS 5041 Part 3)
Inlet Connections 4 × 2.5″ (65mm) Male Instantaneous Couplings (BS 336)
Outlet Connection 150mm (6″) Flanged Outlet
Body Material Spheroidal Graphite Cast Iron (Ductile Iron)
Inlet & NRV Material Copper Alloy (Gunmetal / Brass)
Non-Return Valves 4 × Spring-Loaded Mushroom Type Check Valves
Drain Valve 1″ (25mm) Drain Valve with Blank Cap (BS 5154)
Normal Working Pressure 10 Bar (16 Bar Elevated Rating Depending on Model)
Hydrostatic Test Pressure 20 Bar (Minimum per BS 5041-3)
Surface Finish Fire Red Epoxy / Enamel Coated (Internal & External)

5. Features List

  • ✓ BSI Kitemark certified to BS 5041 Part 3 standard

  • ✓ 4 × 2.5″ BS 336 male instantaneous fire brigade inlet couplings

  • ✓ Individual spring-loaded non-return valves on every inlet

  • ✓ 150mm (6″) flanged main discharge outlet for dry/wet risers

  • ✓ Heavy-duty ductile iron body with corrosion-resistant copper alloy trim

  • ✓ Integrated 1″ drain valve and protective dust caps included

  • ✓ High-visibility fire red internal and external protective coating

6. Benefits For Customers

  • Faster Emergency Fire Response: Allows up to four fire brigade hoses to pump water simultaneously into building risers without delay.

  • Hassle-Free Safety Audit Approval: BSI Kitemark certification satisfies strict fire consultant, FSCD, and international buyer compliance requirements in Bangladesh.

  • Prevents Pressure Loss & Backflow: Independent check valves ensure water enters the riser one way, even if fewer than four hoses are connected.

  • Durable for Outdoor Bangladesh Weather: Heavy-duty red protective coating and copper alloy couplings resist monsoon humidity, rain, and corrosion.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the 4-way breeching inlet horizontally or vertically (as specified by project drawings) at street/fire brigade access level, typically 750mm to 1,000mm above finished ground level, inside a standard BS 5041-5 recessed or surface-mounted breeching inlet cabinet.

  • Bolt the 150mm flanged outlet securely to the main riser pipe using an approved rubber/EPDM flange gasket and high-tensile bolts.

  • Ensure unobstructed road access for fire brigade appliances and clear signage reading “DRY RISER INLET” or “FIRE BRIGADE CONNECTION”.

Maintenance Tips:

  • Inspect the four male instantaneous couplings and rubber sealing washers every six months to confirm smooth hose locking and zero wear.

  • Keep protective blank caps fitted at all times when not in use to prevent insects, dust, or debris from jamming the non-return valves.

  • Operate the 1-inch drain valve during annual hydrostatic pressure tests to flush sediment and verify tight shutoff.

Safety Instructions:

  • Never obstruct the breeching inlet cabinet with parked vehicles, storage materials, or locked non-breakable doors.

  • Depressurize the riser system completely via the drain valve before unbolting the main flange or servicing internal non-return valves.

8. FAQ Section

Q: What is the price of a 4-Way Fire Brigade Breeching Inlet in Bangladesh? A: The price of a BSI Kitemark-certified 4-Way Breeching Inlet (EM / AE or equivalent) in Bangladesh depends on brand selection, pressure rating, and order quantity. Contact loopshop.com.bd for an immediate BDT quotation.

Q: Where can I buy a 4-Way Breeching Inlet in Bangladesh? A: You can order genuine BSI Kitemark-certified 4-Way Fire Brigade Breeching Inlets online at loopshop.com.bd or through Loop Engineering, with delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all industrial zones.

Q: What warranty does this product have? A: This product includes a manufacturer defect warranty backed by Loop Shop. Reach out to our engineering team for full warranty documentation and Kitemark test certificates.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its spheroidal graphite cast iron body with internal/external protective red coating and copper alloy couplings resists rust, heavy monsoon humidity, and outdoor exposure across Bangladesh.

Q: How to install this product? A: Mount the assembly at ground-level fire brigade access inside a dedicated inlet cabinet and bolt its 150mm flanged outlet onto the building’s 6-inch dry riser or sprinkler supply header using a standard flange gasket.

Q: What is the difference between a 2-way and a 4-way breeching inlet?A: A 2-way breeching inlet features two 2.5″ inlets and a 100mm (4″) outlet for smaller risers, whereas a 4-way breeching inlet features four 2.5″ inlets and a 150mm (6″) outlet for higher water flow demands in large commercial or industrial buildings.

Q: Why is BSI Kitemark certification important for a breeching inlet?A: BSI Kitemark certification to BS 5041 Part 3 proves that the valve assembly has been independently tested for burst pressure, non-return valve sealing, and exact BS 336 coupling dimensions—critical for passing fire safety audits.

Q: Does each of the 4 inlets have its own check valve? A: Yes. Each of the four 2.5″ male instantaneous inlets is fitted with an independent spring-loaded mushroom-type non-return valve to prevent water backflow.

Q: What is the 1-inch drain valve used for? A: The integrated 1-inch drain valve allows maintenance teams or firefighters to safely drain water out of the dry riser pipe after firefighting operations or periodic hydrostatic testing.

Q: Can this breeching inlet be used for both dry risers and sprinkler systems? A: Yes, 4-way breeching inlets are widely installed as fire brigade connections for 150mm dry riser mains as well as external fire department connections for automatic sprinkler and hydrant systems.

Reviews

There are no reviews yet.

Be the first to review “4-Way Fire Brigade Connection (Breeching Inlet) (EM / AE or equivalent) — Kitemark”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581