Description
Product Overview
What is this product? The Shield SD-WFD25 is a vane-type electromechanical water flow detector engineered specifically for 65 mm (2-1/2 inch) wet-pipe automatic fire sprinkler piping systems.
How does it work? A flexible polymer paddle (vane) extends into the sprinkler pipe through a drilled hole. When a fire triggers a sprinkler head or inspector’s test valve, water flows through the pipe and deflects the paddle. This mechanical movement activates a built-in pneumatic time-delay (retard) mechanism, which transfers motion to two synchronized Single-Pole Double-Throw (SPDT) microswitches—sending a reliable alarm signal to the Fire Alarm Control Panel (FACP) and local notification devices.
Who needs this product? Fire protection contractors, MEP engineers, factory compliance managers, and building facility operators designing, installing, or upgrading wet sprinkler networks.
Why is it useful in Bangladesh? Garment factories, textile mills, corporate towers, and industrial warehouses across Dhaka, Gazipur, Chattogram, and Narayanganj undergo rigorous safety audits (NFPA 13, BNBC, and international buyer compliance). The Shield SD-WFD25 carries both UL Listing and FM Approval, ensuring smooth inspection sign-offs and dependable zone-level alarm monitoring even in facilities with fluctuating municipal or booster pump pressures.
Key Features
-
Dual UL Listed & FM Approved Certification: Tested and certified to international fire protection standards for commercial and industrial wet-pipe sprinkler systems.
-
65 mm (2-1/2″) Precision Vane Design: Contoured non-corrosive paddle engineered specifically for Schedule 10 through Schedule 40 2-1/2 inch steel pipes.
-
Adjustable Pneumatic Retard Mechanism: Built-in 0 to 90-second mechanical time delay prevents false alarms from transient pressure surges or water hammer without needing external power.
-
Dual SPDT Microswitches: Provides two independent Form-C dry contacts to simultaneously signal the main fire alarm panel and auxiliary local bells or relays.
-
Rugged Corrosion-Resistant Enclosure: Die-cast housing with a durable powder-coated finish protects internal switches from dust, moisture, and industrial environments.
-
Tamper-Resistant Cover Screws: Secures the housing against unauthorized access while allowing straightforward calibration during commissioning.
Technical Advantages
-
False-Alarm Immunity: Pneumatic retard automatically resets if a pressure surge subsides before the preset delay expires, preventing nuisance evacuations.
-
Zero Standby Power Consumption: Purely mechanical flow sensing and dry-contact switching draw zero quiescent current from the fire alarm loop.
-
High Mechanical & Electrical Reliability: Sealed microswitch assembly ensures crisp contact closure even after years of stagnant standby conditions.
-
Simplified Field Commissioning: Easy-to-read dial adjustment for delay timing and clear terminal blocks speed up installation and zone testing.
Applications
-
Industrial & RMG Factories: Zonal sprinkler monitoring across production floors, cutting sections, and storage warehouses.
-
Commercial Buildings: High-rise office complexes, shopping malls, hotels, and convention centers.
-
Healthcare & Pharmaceuticals: Hospitals, cleanrooms, and laboratory facilities requiring pinpoint fire zone identification.
-
Project Installations: New NFPA 13 wet-pipe sprinkler installations, riser manifolds, and fire safety system retrofits.
Why Choose This Product?
-
Audit-Ready Dual Approvals: Carries both UL and FM certifications, eliminating compliance bottlenecks during factory and building inspections.
-
Proven Brand Dependability: Shield Fire Protection products are widely trusted across fire safety projects in Bangladesh for consistent build quality.
-
Cost-Effective Zonal Monitoring: Delivers accurate floor-by-floor or zone-by-zone sprinkler activation feedback at a competitive project price.
-
Local Engineering Support: Supplied in Bangladesh through loopshop.com.bd with technical compatibility guidance and prompt nationwide delivery.
4. Technical Specification Table
| Specification | Details |
| Model | SD-WFD25 |
| Brand | Shield |
| Product Type | Vane-Type Water Flow Switch / Detector |
| Nominal Pipe Size | 65 mm (2-1/2 Inch) |
| Certifications | UL Listed & FM Approved |
| Switch Contact Configuration | Two (2) SPDT (Form C) Microswitches |
| Retard / Time Delay | Adjustable Pneumatic Delay (0 – 90 Seconds) |
| Service Application | Wet-Pipe Fire Sprinkler Systems |
| Mounting Type | Saddle Clamp onto Drilled Steel Pipe |
| Enclosure Finish | Red Powder-Coated Corrosion-Resistant Housing |
5. Features List
-
✓ UL Listed and FM Approved for wet sprinkler systems
-
✓ Designed for 65 mm (2-1/2 inch) steel sprinkler piping
-
✓ Adjustable pneumatic time delay prevents pressure-surge false alarms
-
✓ Dual SPDT dry contacts for FACP and local alarm signaling
-
✓ Flexible, corrosion-proof polymer flow detection paddle
-
✓ Rugged weather- and dust-resistant red enclosure
-
✓ Compatible with Schedule 10 and Schedule 40 pipes
6. Benefits For Customers
-
Eliminates Costly False Alarms: Built-in pneumatic retard filters out brief water pressure spikes caused by pump startups or municipal supply fluctuations.
-
Pinpoints Fire Location Fast: Identifies the exact sprinkler zone or floor where water is flowing, speeding up emergency response.
-
Ensures Smooth Safety Audits: Dual UL/FM marks satisfy stringent Bangladesh industrial, commercial, and international buyer fire safety requirements.
-
Low Maintenance & Long Service Life: Non-corrosive wetted components resist rust and scale buildup in local fire water networks.
7. Installation & Maintenance Guide
Installation Requirements:
-
Mount the Shield SD-WFD25 on a straight run of 65 mm (2-1/2″) wet sprinkler pipe at least 6 inches (150 mm) from any fitting that changes water direction and at least 24 inches (600 mm) from any valve or drain.
-
Drill the manufacturer-specified hole size cleanly into the pipe centerline, deburr all sharp edges so the paddle cannot snag, and secure the U-bolt saddle evenly.
-
Ensure the directional flow arrow on the switch housing matches the actual water flow direction toward the sprinkler heads.
Maintenance Tips:
-
Test water flow quarterly (or per NFPA 25 schedule) by opening the downstream inspector’s test connection and verifying alarm activation within the configured delay window (typically under 90 seconds).
-
Inspect the enclosure gasket and conduit entries periodically to confirm moisture and dust protection remain intact.
Safety Instructions:
-
Always depressurize and drain the sprinkler zone pipe completely before drilling the mounting hole or removing the switch saddle.
-
Disconnect alarm circuit power before wiring the SPDT terminals to prevent short circuits or unintended fire alarm panel activation.
8. FAQ Section
Q: What is the price of Shield SD-WFD25 65 mm (2-1/2″) Water Flow Switch in Bangladesh? A: The price of the Shield SD-WFD25 Water Flow Switch in Bangladesh depends on order quantity and current import rates. Visit loopshop.com.bd or contact our sales team for the latest BDT unit and project pricing.
Q: Where can I buy Shield SD-WFD25 Water Flow Switch in Bangladesh? A: You can order genuine Shield UL/FM fire protection devices directly from loopshop.com.bd with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and throughout Bangladesh.
Q: What warranty does this product have? A: The Shield SD-WFD25 is backed by a manufacturer defect warranty through Loop Shop. Reach out to our technical team for complete warranty coverage details on project orders.
Q: Is this suitable for the Bangladesh climate? A: Yes. Its sealed, powder-coated enclosure and corrosion-resistant internal components are built to perform reliably in high-humidity, dusty industrial and commercial environments across Bangladesh.
Q: How to install this product? A: Drain the 65 mm (2-1/2″) sprinkler pipe, drill the specified mounting hole on a straight pipe section, insert the flexible paddle aligned with the flow arrow, tighten the U-bolt saddle, and wire the SPDT contacts to your fire alarm zone module.
Q: Can this water flow switch be used on dry-pipe or deluge sprinkler systems? A: No. Vane-type water flow switches like the SD-WFD25 are designed exclusively for wet-pipe sprinkler systems and must not be used in dry-pipe, pre-action, or deluge systems where high-velocity air/water surges can damage the paddle.
Q: Why does the Shield SD-WFD25 have a time delay (retard) feature? A: The adjustable pneumatic retard delays alarm signaling for a preset duration (up to 90 seconds) so momentary water surges from pump testing or supply pressure changes do not trigger false fire alarms.
Q: Is the Shield SD-WFD25 compatible with addressable fire alarm panels? A: Yes. Its dry SPDT switch contacts connect directly to conventional zone circuits or addressable monitor modules from brands like Simplex, GST, Edwards,Notifier, and Hochiki.
Q: What pipe schedules fit the 65 mm (2-1/2″) SD-WFD25? A: It is engineered to fit standard 65 mm (2-1/2 inch) Schedule 10 through Schedule 40 steel fire sprinkler pipes.
Q: Does this product carry both UL and FM approvals? A: Yes, the Shield SD-WFD25 is both UL Listed and FM Approved for automatic fire sprinkler service.

Reviews