Shield SD-WFD80 150 mm (6″) UL/FM Water Flow Switch for Fire Sprinkler

                                                          • Primary Purpose: Detects sustained water movement inside 150 mm (6-inch) wet fire sprinkler pipes and transmits an immediate electrical alarm signal to the fire alarm control panel.

                                                          • Important Specifications: Model SD-WFD80, 150 mm (6″) pipe size, UL Listed & FM Approved, weather-resistant NEMA 4 enclosure, and adjustable mechanical retard timer (0–90 seconds).

                                                          • Customer Benefits: Prevents false alarms caused by water pressure surges while ensuring rapid fire sprinkler activation alerts and code-compliant life safety monitoring.

                                                          • Bangladesh Market Relevance: Essential for RMG textile factories, pharmaceutical plants, warehouses, and commercial high-rises in Bangladesh requiring strict NFPA 13, UL/FM, and factory safety audit compliance.

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1-1 Category Tags: , , , , , , , , , , Brand:

Description

Product Overview

What is this product? The Shield SD-WFD80 150 mm (6″) Water Flow Switch is a vane-type electromechanical supervisory device designed to monitor water flow in 6-inch wet-pipe automatic fire sprinkler systems.

How does it work? A flexible, non-corrosive polyethylene paddle (vane) extends inside the 150 mm sprinkler riser or branch pipe. When one or more sprinkler heads activate during a fire, water flows through the pipe and deflects the vane. This movement engages a pneumatic/mechanical time-delay retard mechanism (adjustable up to 90 seconds to filter out brief water hammer or pressure surges) before actuating dual SPDT micro-switches that send an alarm signal to the Fire Alarm Control Panel (FACP) and local alarm bells.

Who needs this product? Fire protection contractors, MEP engineers, factory safety compliance officers, and building facility managers installing or upgrading wet sprinkler networks.

Why is it useful in Bangladesh? Industrial complexes, garment factories, and commercial buildings across Dhaka, Gazipur, Chattogram, and Narayanganj face frequent municipal/pump pressure fluctuations and rigorous fire safety inspections (NFPA 13, BNBC, and international buyer audits). The Shield SD-WFD80 combines genuine UL/FM certification with an adjustable retard timer to eliminate nuisance alarms while guaranteeing reliable alarm signaling.

Key Features

  • Dual UL Listed & FM Approved Certification: Independently tested and certified for wet-pipe fire sprinkler alarm service.

  • Adjustable Mechanical Retard Mechanism: Built-in 0 to 90-second pneumatic time delay prevents false alarms from transient pressure spikes or water hammer.

  • Dual SPDT Snap-Action Switches: Provides two independent Form-C dry contacts for simultaneous Fire Alarm Control Panel signaling and auxiliary device triggering.

  • Rugged NEMA 4 / IP56 Rated Enclosure: Die-cast aluminum housing protects internal switches from dust, moisture, and splash exposure in pump rooms and riser shafts.

  • Tamper-Resistant Cover Screws: Equipped with tamper-proof housing screws to prevent unauthorized access or accidental calibration changes.

  • Durable Flexible Paddle: Engineered to withstand high flow velocities without deforming or corroding inside fire water lines.

Technical Advantages

  • False-Alarm Immunity: Precision retard timer distinguishes between momentary pressure surges and genuine sprinkler head discharge.

  • High-Visibility Calibration Dial: Easy-to-read retard adjustment dial allows fast, accurate commissioning on-site without special tools.

  • Corrosion-Resistant Wetted Parts: Non-metallic paddle and sealed stem assembly resist mineral buildup and rust in stagnant sprinkler water.

  • Simple Saddle-Clamp Mounting: Installs directly onto standard 150 mm (6″) Schedule 10 through Schedule 40 steel pipes via a pre-drilled hole and U-bolt saddle assembly.

Applications

  • Industrial & RMG Factories: Main wet sprinkler risers and zone control assemblies in garment factories, spinning mills, and warehouses.

  • Commercial Buildings: High-rise office towers, shopping malls, hotels, and convention centers.

  • Pharmaceutical & Healthcare: Hospitals, laboratories, and cleanroom production facilities.

  • Project Installations: New NFPA 13 sprinkler installations, zone valve assemblies, and fire safety audit retrofits.

Why Choose This Product?

  • Verified Global Approvals: UL Listed and FM Approved credentials ensure smooth acceptance by fire safety inspectors and insurance auditors in Bangladesh.

  • Reliable Switch Performance: Industrial-grade snap-action micro-switches deliver consistent electrical contact closure over long standby periods.

  • Cost-Effective Compliance: Offers dependable UL/FM performance at a competitive price point for large-scale industrial and commercial projects.

  • Local Engineering Support: Supplied in Bangladesh via loopshop.com.bd with technical verification and nationwide delivery.

4. Technical Specification Table

Specification Details
Model SD-WFD80
Brand Shield
Product Type Vane-Type Water Flow Detector / Switch
Pipe Size 150 mm (6 Inch)
Certifications UL Listed, FM Approved
Pipe Compatibility Schedule 10 to Schedule 40 Steel Pipe
Contact Configuration Two (2) SPDT (Form-C) Snap-Action Micro-Switches
Contact Rating 10A @ 125/250 VAC; 2.5A @ 24 VDC
Retard Adjustment Range 0 to 90 Seconds (Pneumatic/Mechanical)
Enclosure Rating NEMA 4 / IP56 Weather-Resistant Die-Cast Housing
Conduit Entrance Two (2) 1/2″ NPT Knockouts
Operating Temperature 4.5°C to 49°C (40°F to 120°F)
Service Pressure Rating Up to 450 PSI (31 Bar)
Mounting Method U-Bolt Saddle Clamp on Pre-Drilled Pipe Hole

5. Features List

  • ✓ UL Listed and FM Approved for wet fire sprinkler systems

  • ✓ Fits standard 150 mm (6″) Schedule 10–40 fire pipes

  • ✓ Adjustable 0–90 second retard timer eliminates false alarms

  • ✓ Dual SPDT dry contacts for FACP and auxiliary signaling

  • ✓ Rugged NEMA 4 weather-resistant die-cast aluminum housing

  • ✓ Tamper-resistant cover with dual 1/2″ conduit entries

  • ✓ High-strength corrosion-resistant flexible flow vane

6. Benefits For Customers

  • Eliminates Costly False Alarms: Adjustable retard delay prevents pump pressure fluctuations from triggering unnecessary factory evacuations.

  • Passes Fire Safety Audits: Full UL/FM certification satisfies NFPA 13, BNBC, and international buyer compliance inspections in Bangladesh.

  • Fast Installation & Wiring: U-bolt mounting and dual conduit entries simplify installation on 6-inch risers and zone control valves.

  • Reliable in Humid Environments: Sealed NEMA 4 enclosure protects electrical contacts against dust and humidity in Bangladesh mechanical rooms.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the switch on a straight horizontal or vertical section of 150 mm (6″) wet sprinkler pipe, maintaining at least 150 mm (6″) clearance from fittings and 600 mm (24″) from valves or elbows to avoid turbulence.

  • Drill a clean, burr-free mounting hole in the pipe according to the manufacturer template, insert the rolled vane carefully, and tighten the U-bolt nuts evenly.

  • Ensure the directional flow arrow on the saddle matches the actual water flow direction toward the sprinklers.

Maintenance Tips:

  • Perform quarterly operational tests using the inspector’s test connection valve to verify alarm actuation within 90 seconds.

  • Inspect the enclosure gasket and conduit fittings periodically to ensure moisture and dust seals remain intact.

  • Keep the vane area free of debris or pipe scale during system flushing.

Safety Instructions:

  • Drain and depressurize the sprinkler pipe zone completely before drilling the pipe or removing the water flow switch.

  • Disconnect electrical power to the alarm circuit before wiring the SPDT terminals to prevent short circuits or FACP faults.

8. FAQ Section

Q: What is the price of Shield Water Flow Switch 150 mm (6″) SD-WFD80 in Bangladesh? A: The price of the Shield SD-WFD80 150 mm (6″) UL/FM Water Flow Switch in Bangladesh depends on order quantity and project requirements. Contact loopshop.com.bd for the latest BDT unit price and bulk project discounts.

Q: Where can I buy Shield SD-WFD80 Water Flow Switch in Bangladesh? A: You can order genuine Shield UL/FM water flow switches directly online from loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.

Q: What warranty does this product have? A: The Shield SD-WFD80 includes a standard manufacturer defect warranty backed by Loop Shop. Contact our team with your project specifications for full warranty terms.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its NEMA 4 sealed die-cast enclosure and non-corrosive internal components are built to withstand high humidity, dust, and ambient temperatures in Bangladesh industrial facilities.

Q: How to install this product? A: Depressurize the 6-inch pipe, drill the specified mounting hole, insert the flexible paddle aligned with the flow arrow, secure the U-bolt saddle, wire the SPDT terminals to your Fire Alarm Control Panel, and set the retard timer.

Q: What does UL/FM approval mean for this flow switch? A: UL Listing and FM Approval confirm that the Shield SD-WFD80 meets strict international performance and reliability standards required by NFPA 13 and industrial fire safety auditors.

Q: Why does the SD-WFD80 have a retard timer? A: The 0–90 second retard timer delays switch activation briefly so momentary water surges or pump start-up pressure spikes do not cause false fire alarms.

Q: Can this water flow switch be installed on vertical pipes? A: Yes, it can be mounted on either horizontal pipes or vertical pipes where water flows upward. Do not install it where water flows downward.

Q: What pipe schedules are compatible with the 150 mm (6″) SD-WFD80? A: It is compatible with standard 150 mm (6-inch) Schedule 10 through Schedule 40 steel sprinkler pipes.

Q: How many alarm contacts does the Shield SD-WFD80 have? A: It features two independent SPDT (Single-Pole Double-Throw) Form-C switches, allowing simultaneous connection to a Fire Alarm Control Panel and a local supervisory module or bell.

Reviews

There are no reviews yet.

Be the first to review “Shield SD-WFD80 150 mm (6″) UL/FM Water Flow Switch for Fire Sprinkler”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581