Shield SD-WFD80 200mm (8″) UL/FM Vane Type Water Flow Switch

                                                      • Primary Purpose: Detects sustained water movement inside 200 mm (8-inch) fire sprinkler risers or branch pipes and transmits an immediate alarm signal to the Fire Alarm Control Panel (FACP).

                                                      • Key Specifications: Model SD-WFD80, 200 mm (8″) nominal pipe size, UL Listed and FM Approved, dual SPDT microswitches, and adjustable pneumatic retard mechanism.

                                                      • Customer Benefits: Prevents false alarms caused by water pressure surges while ensuring rapid, reliable fire zone identification.

                                                      • Bangladesh Market Relevance: Essential for RMG textile factories, commercial high-rises, and industrial warehouses across Bangladesh requiring strict NFPA 13, BNBC, and Accord/RSC fire safety compliance.

Best Price Guaranteed

Description

Product Overview

What is this product? The Shield SD-WFD80 is a heavy-duty, vane-type electromechanical water flow detector designed for installation on 200 mm (8-inch) wet-pipe automatic fire sprinkler systems.

How does it work? A flexible polyethylene paddle (vane) extends into the sprinkler pipe through a drilled mounting hole. When a fire sprinkler head activates and water flows through the 8-inch pipe, the water stream deflects the paddle. This mechanical movement triggers a built-in pneumatic time-delay (retard) mechanism that filters out brief pressure surges. Once sustained flow is confirmed, two synchronized SPDT microswitches actuate to send a waterflow alarm signal to the building’s Fire Alarm Control Panel and local alarm bells.

Who needs this product? MEP contractors, fire alarm system integrators, facility maintenance engineers, and industrial building owners installing or upgrading automatic fire sprinkler networks.

Why is it useful in Bangladesh? Industrial plants, RMG garment factories, dyeing units, and commercial complexes in Dhaka, Gazipur, Chattogram, and Narayanganj must maintain fully monitored sprinkler risers to meet NFPA 13, BNBC, and international buyer fire safety audits. The Shield SD-WFD80 provides dual UL/FM certification and surge-delay protection suited for local pump-fed sprinkler mains.

Key Features

  • Dual UL Listed & FM Approved Certification: Independently tested and certified to meet international fire protection standards for commercial and industrial sprinkler systems.

  • Adjustable Pneumatic Retard: Built-in mechanical time-delay mechanism prevents false alarms triggered by transient water pressure surges or jockey pump cycling.

  • Dual SPDT Alarm Switches: Equipped with two independent Form-C (SPDT) microswitches for simultaneous connection to the Fire Alarm Control Panel and auxiliary notification devices.

  • Durable Flexible Vane: High-strength, corrosion-resistant molded paddle withstands high flow velocities without permanent deformation.

  • Tamper-Resistant Enclosure: Rugged NEMA-rated die-cast housing with tamper-resistant cover screws protects internal switches against dust, moisture, and unauthorized access.

  • Visual & Audible Retard Adjustment: Easy-to-access calibrated dial allows technicians to set the exact delay duration during commissioning.

Technical Advantages

  • False-Alarm Immunity: Pneumatic retard filters out momentary water hammer and pump start/stop fluctuations common in large industrial piping networks.

  • High Corrosion Resistance: Sealed switch compartment and non-corrosive wetted stem/vane assembly ensure long service life in stagnant sprinkler water.

  • Reliable Electromechanical Switching: Positive snap-action contacts deliver clean, bounce-free dry contact closure to addressable monitor modules or conventional FACP zones.

  • Straightforward Maintenance: Cover removal provides direct access to wiring terminals and delay adjustment without draining the 200 mm sprinkler riser.

Applications

  • Industrial & RMG Factories: Main 8-inch sprinkler risers and sectional zone control assemblies in garment factories, spinning mills, and warehouses.

  • Commercial High-Rises: Office towers, shopping malls, and hotels requiring floor-by-floor or zone-specific sprinkler flow monitoring.

  • Logistics & Cold Storage Facilities: Large-scale distribution centers protected by wet-pipe sprinkler networks.

  • Project Installations: New NFPA 13 fire sprinkler installations, pump room upgrades, and fire audit compliance retrofits.

Why Choose This Product?

  • Audit-Ready Compliance: Carries both UL Listing and FM Approval, satisfying strict fire safety inspections across Bangladesh.

  • Proven System Integration: Compatible with all major addressable monitor modules and conventional fire alarm panels used in Bangladesh.

  • Low Lifecycle Cost: Maintenance-free pneumatic retard and rugged enclosure minimize nuisance callouts and replacement costs.

  • Trusted Local Supply: Supplied by loopshop.com.bd with technical specification support and fast nationwide delivery.

4. Technical Specification Table

Specification Details
Model SD-WFD80
Brand Shield
Product Type Vane Type Water Flow Switch
Nominal Pipe Size 200 mm (8 Inch)
Certification UL Listed / FM Approved
Switch Contacts Dual SPDT (Form C) Microswitches
Time Delay Mechanism Adjustable Pneumatic Retard
Pipe Compatibility Schedule 10 to Schedule 40 Steel Pipe
Mounting Method U-Bolt Saddle Clamp over Drilled Pipe Hole
Enclosure Type Weather/Dust-Resistant Die-Cast Housing with Tamper Screws
System Application Wet-Pipe Fire Sprinkler Systems

5. Features List

  • ✓ UL Listed and FM Approved for wet-pipe fire sprinkler systems

  • ✓ Engineered specifically for 200 mm (8-inch) steel sprinkler pipes

  • ✓ Adjustable pneumatic retard eliminates false alarms from water surges

  • ✓ Dual SPDT (Form C) dry-contact switches for FACP and bell circuits

  • ✓ Flexible, corrosion-proof paddle for long operational life

  • ✓ Tamper-resistant cover screws for enhanced system security

  • ✓ Easy U-bolt saddle installation without cutting the main pipe

6. Benefits For Customers

  • Eliminates Costly False Alarms: Built-in retard delay absorbs jockey pump pressure spikes so production in factories is never disrupted by false evacuations.

  • Fast Fire Zone Pinpointing: Immediately alerts security and fire control rooms to the exact 8-inch riser or zone where sprinkler water is flowing.

  • Passes Fire Safety Audits: Full UL/FM certification meets strict BNBC, NFPA 13, and international buyer compliance checks in Bangladesh.

  • Reliable in Harsh Environments: Sealed housing protects internal electrical contacts from humidity and dust inside mechanical shafts and pump rooms.

7. Installation & Maintenance Guide

Installation Requirements:

  • Drill a clean, burr-free mounting hole of the manufacturer-specified diameter into the 200 mm (8-inch) Schedule 10 or Schedule 40 steel pipe.

  • Maintain at least 6 inches (150 mm) of straight pipe clearance from fittings, elbows, and valves (or 24 inches downstream from check valves/pumps) to avoid turbulent flow.

  • Roll and insert the flexible paddle carefully into the hole, align the flow arrow on the saddle with the direction of water flow, and tighten the U-bolt nuts evenly.

Maintenance Tips:

  • Test water flow alarm activation quarterly or semi-annually by opening the Inspector’s Test Valve at the end of the sprinkler zone.

  • Verify that the alarm signal reaches the Fire Alarm Control Panel within 90 seconds of sustained water flow.

  • Inspect the conduit entry and cover gasket annually to ensure moisture cannot enter the switch housing.

Safety Instructions:

  • Always drain the sprinkler zone and verify zero internal pipe pressure before drilling the pipe or loosening the U-bolt saddle.

  • Disconnect electrical power from the fire alarm monitoring circuit before wiring the SPDT switch terminals.

8. FAQ Section

Q: What is the price of Shield Water Flow Switch 200 mm (8″) SD-WFD80 in Bangladesh? A: The price of the Shield SD-WFD80 200 mm (8″) UL/FM Water Flow Switch in Bangladesh depends on order quantity and current market availability. Contact loopshop.com.bd for an instant BDT quotation or project pricing.

Q: Where can I buy Shield SD-WFD80 Water Flow Switch in Bangladesh? A: You can buy genuine Shield UL/FM fire sprinkler devices directly online at loopshop.com.bd or through Loop Engineering, with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.

Q: What warranty does this product have? A: The Shield SD-WFD80 includes a standard manufacturer defect warranty supported locally by Loop Shop. Contact our team for project-specific warranty documentation.

Q: Is this suitable for the Bangladesh climate? A: Yes. Its sealed die-cast enclosure and corrosion-resistant paddle/stem assembly are engineered to withstand high humidity and ambient heat in Bangladeshi factory pump rooms and riser shafts.

Q: How to install the Shield SD-WFD80 water flow switch? A: Drain the 8-inch pipe, drill the required mounting hole, insert the flexible paddle in the direction of water flow, secure the saddle with the supplied U-bolt, and wire the SPDT contacts to your fire alarm monitor module.

Q: Is the Shield SD-WFD80 UL Listed and FM Approved? A: Yes, the SD-WFD80 carries both UL Listing and FM Approval, ensuring full compliance with NFPA 13 and Bangladesh industrial fire safety audit standards.

Q: Can this water flow switch work with addressable fire alarm systems? A: Yes. Its dual SPDT dry-contact switches connect seamlessly to addressable input/monitor modules from brands such as Simplex, GST, Edwards,Notifier, and Hochiki.

Q: How does it prevent false alarms from pump pressure surges? A: It features an integrated, field-adjustable pneumatic retard mechanism that delays switch activation until sustained water flow is confirmed.

Q: Can this switch be used on dry-pipe or pre-action sprinkler systems? A: Vane-type flow switches like the SD-WFD80 are designed specifically for wet-pipe sprinkler systems; dry-pipe systems typically require pressure-type alarm switches.

Q: What pipe schedules does the SD-WFD80 fit? A: It is compatible with standard 200 mm (8-inch) Schedule 10 through Schedule 40 steel fire sprinkler pipes.

Reviews

There are no reviews yet.

Be the first to review “Shield SD-WFD80 200mm (8″) UL/FM Vane Type Water Flow Switch”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581