Fire Water Tank Level Indicator

                      • Continuous Water Reserve Monitoring: Designed specifically for fire protection systems to provide real-time visual and digital readings of water levels inside underground or overhead fire suppression reservoirs.

                      • High-Precision Sensor Technology: Utilizes industrial-grade ultrasonic or hydrostatic level sensing paired with a clear LED/LCD display panel and programmable high/low-level alarm relays.

                      • Prevents Dry-Run & Ensures Compliance: Protects expensive fire pumps from dry-running damage while helping facilities maintain mandatory fire safety water reserve standards.

                      • Built for Bangladesh Industrial Facilities: Ideal for RMG factories, textile mills, commercial high-rises, and warehouses across Bangladesh requiring strict compliance with BNBC, FSCD, and NFPA fire safety guidelines.

Best Price Guaranteed

Description

Product Overview

A Fire Water Tank Level Indicator is an essential electronic instrumentation device used in fire fighting pump rooms and water storage reservoirs to continuously measure, display, and monitor the exact volume or depth of dedicated fire reserve water.

The system operates via a precision sensing element (such as a submersible hydrostatic pressure transmitter or top-mounted ultrasonic sensor) installed inside the fire water tank, which transmits real-time level signals to a wall-mounted digital display controller in the fire pump room or central BMS (Building Management System) panel. Facility managers, safety officers, and pump operators rely on this instrument to verify that mandatory emergency water reserves are always full. In Bangladesh, where RMG factories, commercial towers, and industrial plants must adhere strictly to Bangladesh National Building Code (BNBC), Fire Service and Civil Defence (FSCD), and RSC/Accord/NFPA standards, maintaining verifiable fire water storage is critical for life safety and audit compliance.

Key Features

  • Real-Time Level Readout: Clear digital LED/LCD display showing water level in percentage (%), meters, or liters for instant visibility inside dimly lit pump rooms.

  • Programmable Alarm Outputs: Built-in relay contacts for low-level and high-level audio-visual alarms to alert operators immediately if water drops below the minimum fire reserve threshold.

  • BMS & Fire Alarm Integration: Standard analog (4–20mA) and digital relay outputs allow seamless connection to Fire Alarm Control Panels (FACP) and Building Management Systems.

  • Corrosion-Resistant Sensor Probe: Engineered to withstand continuous submersion in treated or raw water without signal drift or premature degradation.

  • Automatic Refill Pump Interlock: Capable of triggering makeup water solenoid valves or transfer pumps automatically when water levels dip.

Technical Advantages

  • High Measurement Accuracy: Delivers stable, repeatable level readings unaffected by surface ripples or humidity fluctuations inside enclosed concrete or steel water tanks.

  • Industrial-Grade Durability: Housed in a rugged, dust- and moisture-resistant enclosure suited for demanding mechanical and pump room environments.

  • Pump Dry-Run Protection: Integrates with fire pump controllers to prevent catastrophic mechanical seal and impeller damage caused by low water conditions.

  • Low Power Consumption: Energy-efficient low-voltage control circuitry ensures continuous 24/7 operation with minimal electrical load.

  • Zero-Hassle Maintenance: Solid-state sensing eliminates mechanical floats that commonly jam, corrode, or fail over time.

Applications

  • RMG & Textile Factories: Dedicated underground and overhead fire reserve tanks in Gazipur, Savar, Narayanganj, and Chattogram industrial zones.

  • Commercial High-Rise Buildings: Shopping malls, corporate offices, hotels, and hospitals requiring automated fire water supervision.

  • Industrial Plants & Warehouses: Pharmaceutical facilities, power plants, food processing units, and logistics hubs.

  • Fire Pump Rooms: Direct panel-mounted monitoring next to electric, diesel, and jockey fire pumps.

  • MEP & Fire Protection Projects: Turnkey sprinkler and hydrant installations requiring BNBC and NFPA-compliant instrumentation.

Why Choose This Product?

  • Audit-Ready Compliance: Provides clear, verifiable water reserve status required during FSCD, insurance, and international buyer safety inspections.

  • Operational Reliability: Eliminates manual dipstick checks and unreliable mechanical sight glasses with automated 24/7 electronic monitoring.

  • Cost-Effective Asset Protection: Prevents costly fire pump failures and water overflow wastage through precise level control and automated alerts.

  • Dedicated Technical Support: Backed by Loop Engineering & Loop Shop Bangladesh for sizing guidance, wiring support, and project supply across the country.

================================================

4. Technical Specification Table

Specification Details
Product Type Digital Fire Water Tank Level Indicator & Controller
Display Type High-Brightness Digital LED / LCD Display
Measurement Units Percentage (%), Meters (m), or Liters (L)
Sensing Technology Hydrostatic Submersible / Ultrasonic Non-Contact
Power Supply 220V AC, 50Hz / 24V DC (Model Dependent)
Output Signal 4–20mA Analog Output & Relay Alarm Contacts
Alarm Function Programmable High-Level & Low-Level Audio-Visual Alarms
Sensor Material Stainless Steel (SS304/SS316) / Industrial ABS
Enclosure Protection IP65 (Display Controller) / IP68 (Submersible Sensor)
Mounting Type Wall-Mounted / Panel-Mounted Display; Top/Submerged Tank Sensor
Operating Temperature 0°C to 60°C
Application Underground & Overhead Fire Fighting Water Reservoirs

================================================

5. Features List

  • ✓ Continuous real-time digital water level monitoring

  • ✓ Built-in low-level and high-level programmable alarm relays

  • ✓ Seamless integration with Fire Alarm Control Panels (FACP) & BMS

  • ✓ Corrosion-resistant industrial sensor for long service life

  • ✓ Protects fire fighting pumps from dry-run damage

  • ✓ Easy wall or control panel installation with low maintenance

================================================

6. Benefits For Customers

  • Ensures Constant Fire Readiness: Guarantees your facility’s emergency fire reserve tank is always at full capacity before an incident occurs.

  • Protects High-Value Fire Pumps: Prevents expensive electric and diesel fire pumps from running dry during testing or emergencies.

  • Simplifies Safety Audits: Helps factory owners and facility managers pass FSCD, BNBC, and international compliance inspections effortlessly.

  • Reduces Manual Labor & Overflow Waste: Automates water level tracking and makeup pump control, eliminating manual tank inspections and water wastage.

  • Built for Bangladesh Conditions: Engineered to operate reliably in high-humidity pump rooms and fluctuating local power environments.

================================================

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the digital display controller inside the fire pump room or control room at eye level in a dry, accessible location away from direct water spray.

  • Install the sensor probe vertically inside the fire water tank (submerged near the bottom for hydrostatic sensors, or mounted at the top center away from inlet turbulence for ultrasonic sensors).

  • Route shielded signal cables through protective PVC or GI conduits to prevent electromagnetic interference from nearby high-power fire pump motors.

  • Connect the power supply (220V AC 50Hz or 24V DC as rated) and wire the dry relay contacts to your Fire Alarm Control Panel or annunciator if supervisory monitoring is required.

Maintenance Tips:

  • Visually inspect the digital display readout weekly during routine fire pump churn tests to verify accurate level readings.

  • Clean the sensor head or pressure diaphragm every 6 months to remove sediment, silt, or mineral buildup from tank water.

  • Test the low-level alarm threshold periodically by simulating a low-water condition or performing a controlled drain check.

Safety Instructions:

  • Always isolate the main electrical power supply before opening the controller enclosure or performing any wiring connections.

  • Follow confined-space safety protocols and ensure proper ventilation before entering an underground fire water reservoir for sensor installation or cleaning.

  • Ensure proper earthing/grounding of the control panel to protect sensitive electronic components from voltage surges.

================================================

8. FAQ Section

Q: What is the price of Fire Water Tank Level Indicator in Bangladesh? A: The price of a Fire Water Tank Level Indicator in Bangladesh varies depending on the tank depth, sensor type (ultrasonic or submersible hydrostatic), cable length, and relay output requirements. Contact Loop Shop Bangladesh for an exact quotation tailored to your tank dimensions.

Q: Where can I buy Fire Water Tank Level Indicator in Bangladesh? A: You can purchase genuine Fire Water Tank Level Indicators directly online from loopshop.com.bd or through Loop Engineering, with fast delivery and technical support across Dhaka, Gazipur, Chattogram, Narayanganj, and nationwide.

Q: What warranty does this product have? A: This product comes with a standard manufacturer/supplier warranty covering manufacturing defects, along with dedicated technical and after-sales support from Loop Shop Bangladesh.

Q: Is this suitable for Bangladesh climate? A: Yes, the display enclosure and industrial sensor are designed to withstand high ambient humidity, dust, and temperature variations typical in Bangladeshi pump rooms and underground water reservoirs.

Q: How to install this product? A: Mount the digital display unit inside the fire pump room, lower or mount the sensor inside the fire water tank according to tank depth, connect the shielded signal cable, and wire the power supply and alarm relays to your control panel.

Q: Can this level indicator connect to a Fire Alarm Control Panel (FACP)? A: Yes, it includes dry relay contacts (NO/NC) and optional 4–20mA output that integrate directly with supervisory modules on conventional or addressable Fire Alarm Control Panels.

Q: Does it work for both underground and overhead fire water tanks? A: Yes, the controller can be calibrated for custom tank heights and shapes, making it suitable for both underground concrete reservoirs and rooftop overhead fire tanks.

Q: How does it protect fire fighting pumps? A: By triggering a low-water alarm or sending a cutoff interlock signal when water drops to a critical minimum, it prevents electric and diesel fire pumps from dry-running and burning out mechanical seals.

Q: What sensor type is better for fire water tanks—ultrasonic or hydrostatic? A: Submersible hydrostatic sensors are ideal for deep underground tanks with internal beams or heavy condensation, while ultrasonic sensors work well for clean overhead tanks where non-contact measurement is preferred.

Q: Can it automatically control a makeup water pump or solenoid valve? A: Yes, the programmable relay outputs can be configured to automatically start a refill pump when water drops below a set point and stop it once the tank reaches full capacity.

Reviews

There are no reviews yet.

Be the first to review “Fire Water Tank Level Indicator”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581