Fiffco DN150 150 mm (6″) Flanged Y-Strainer Non-Listed for Fire & Water

      • Primary Function: Mechanically filters rust, pipe scale, sand, and solid debris from pressurized water pipelines to protect downstream fire pumps, control valves, pressure reducing valves (PRVs), and sprinkler heads.

      • Key Specifications: Nominal diameter 150 mm (6 inches / DN150), flanged end connections, removable perforated stainless steel filter screen, heavy-duty cast/ductile iron body, and Non-Listed certification (Fiffco or equivalent standard, Origin: China).

      • Operational Advantage: Features a bolted blow-off cover that lets maintenance technicians extract and clean the internal mesh basket without dismounting the valve body from the main pipeline.

      • Bangladesh Market Relevance: Engineered for commercial high-rises, RMG factories, and industrial fire hydrant/water supply networks across Bangladesh where reliable, cost-effective non-listed pipeline filtration is required.

Best Price Guaranteed

Description

Product Overview

What is this product?The Fiffco (or equivalent) 150 mm (6″) Non-Listed Y-Strainer is a heavy-duty inline mechanical filtration device designed for large-bore pressurized water and fire protection piping networks. Named after its distinct Y-shaped body geometry, it houses an angled cylindrical mesh screen that captures unwanted particulate matter suspended in the fluid stream.

How does it work? As water flows through the 150 mm main inlet, it is directed through an angled, perforated stainless steel filter basket. Solid contaminants—such as welding slag, rust flakes, pebbles, and sediment—are trapped inside the screen while clean water passes smoothly through the outlet with minimal pressure drop. Trapped debris settles at the bottom of the Y-leg and can be flushed via the drain plug or removed by unbolting the strainer cover.

Who needs this product? MEP contractors, fire safety engineers, industrial plant maintenance teams, HVAC installers, and building developers require this component for main distribution headers, fire pump suction lines, and upstream protection of sensitive control equipment.

Why is it useful in Bangladesh? Municipal water supplies, deep tube wells, and underground fire water reservoirs in Bangladesh frequently carry sand, silt, and scale caused by pipe corrosion. Installing a 6-inch Y-strainer prevents impeller damage in fire and booster pumps and stops clogging in check valves, PRVs, and sprinkler risers—making it a practical, budget-conscious solution for projects that do not strictly mandate UL/FM listed hardware.

Key Features

  • 150 mm (6″ / DN150) Nominal Bore: Sized for high-volume main risers, pump room headers, and industrial distribution lines.

  • Removable Stainless Steel Screen: Corrosion-resistant perforated mesh filter easily lifts out for rapid inspection, flushing, and reuse.

  • Inline Serviceability: Bolted access cover allows full basket cleaning without removing the flanged strainer housing from the piping system.

  • Rugged Metallic Body Construction: Built to withstand continuous hydrostatic pressure and mechanical pipe stress in demanding pump room environments.

  • Flanged End Connections: Standard drilled flanges ensure rigid, leak-free bolt-up with matching 6-inch gate valves, check valves, and piping flanges.

  • Non-Listed Specification: Cost-effective standard commercial/industrial grade (Fiffco or equivalent, Origin: China) tailored for non-UL/FM project specifications.

Technical Advantages

  • Equipment Protection: Prevents abrasive particles from scoring pump impellers, jamming non-return valve discs, or fouling pressure reducing valve seats.

  • Low Pressure Drop Design: Angled screen chamber maximizes open filtration area relative to the 150 mm pipe bore, maintaining strong hydraulic flow rates.

  • Corrosion Resistance: Protective exterior coating and stainless steel internal mesh resist internal oxidation and humid plant room conditions.

  • Easy Maintenance: Integrated drain/blow-off port on the cover enables routine sediment purging without full system disassembly.

Applications

  • Industrial & Factory: Garment (RMG) factories, textile mills, pharmaceutical plants, and manufacturing facilities.

  • Commercial: High-rise office towers, shopping malls, hotels, and hospitals.

  • Project Installation: Fire pump suction lines, hydrant ring mains, zone control assemblies, HVAC chilled water headers, and booster pump stations.

  • Residential: Large apartment complexes and central water supply pump rooms.

Why Choose This Product?

  • Proven Hydraulic Reliability: Keeps critical fire-fighting and water transfer valves free from debris-induced failure during emergency operation.

  • Cost-Effective Compliance: Delivers dependable mechanical filtration for Bangladeshi industrial and commercial projects where UL/FM certification is not specified in the BOQ, keeping procurement within budget.

  • Local Supply & Support: Available through loopshop.com.bd with engineering consultation, datasheet support for client submittals, and nationwide delivery across all 64 districts of Bangladesh.

4. Technical Specification Table

(Note: Because “Fiffco or equivalent — Non-Listed” is a mechanical pipeline strainer without electrical ratings, only verified mechanical and project parameters are listed below.)

Specification Details
Product Type Y-Type Pipeline Strainer
Brand / Make Fiffco (or Equivalent)
Nominal Size 150 mm (6 Inch / DN150)
Certification / Listing Non-Listed
Connection Type Flanged Ends
Filter Element Removable Stainless Steel Mesh Screen
Body Material Cast Iron / Ductile Iron (Standard Commercial Grade)
Power / Voltage / Current Mechanical Component (Non-Electrical — Zero Power Required)
Medium Water / Fire Protection & Industrial Piping Fluids
Country of Origin China
Warranty Supplied with Standard Supplier Defect Replacement Guarantee (Contact Loop Engineering for project terms)

5. Features List

✓ 150 mm (6″) nominal bore for high-flow main water and fire pipelines

✓ Removable perforated stainless steel filter basket for easy cleaning

✓ Protects fire pumps, PRVs, check valves, and sprinklers from rust and debris

✓ Heavy-duty flanged body for secure, leak-tight pipeline installation

✓ Bolted cover allows inline maintenance without removing the strainer body

✓ Cost-effective Non-Listed specification ideal for non-UL/FM BOQ requirements

6. Benefits For Customers

  • Protects Expensive Downstream Equipment: Stops stones, welding slag, and pipe rust before they reach fire pump impellers, zone control valves, and pressure reducing valves—preventing costly breakdowns.

  • Reduces Maintenance Downtime: Technicians can unbolt the strainer cap, slide out the stainless steel screen, rinse it, and reinstall it within minutes without cutting or unbolting main 6-inch pipe flanges.

  • Optimizes Project Budgets: Meets technical filtration needs for local industrial, commercial, and fire hydrant projects in Bangladesh without paying the premium of UL/FM-listed imports.

  • Built for Bangladesh Operating Conditions: Handles sediment-heavy underground reservoir water and humid pump room environments reliably.

7. Installation & Maintenance Guide

Installation Requirements:

  • Install the Y-strainer upstream of the equipment you intend to protect (such as fire pump suction inlets, PRVs, control valves, or flow meters).

  • Verify the flow direction arrow cast onto the strainer body matches the pipeline flow direction.

  • In horizontal pipelines, position the strainer leg pointing vertically downward so trapped debris collects naturally in the pocket rather than falling back into the flow stream.

  • Ensure sufficient clearance below or in front of the bolted cover so the stainless steel screen can be fully extracted during servicing.

  • Use compatible flange gaskets and tighten flange bolts in a star pattern to ensure a uniform, leak-free seal.

Maintenance Tips:

  • Flush the strainer frequently during initial system commissioning to clear construction debris, sand, and welding scale.

  • Monitor differential pressure across the strainer; clean the filter screen whenever pressure drop increases noticeably or during scheduled quarterly/semi-annual fire system inspections.

  • Inspect the stainless steel mesh for tears or deformation and check the cover gasket for wear before reassembling.

Safety Instructions:

  • Never loosen the cover bolts or blow-off plug while the pipeline is pressurized.

  • Isolate the strainer using upstream and downstream isolation valves (such as OS&Y gate valves or butterfly valves) and completely bleed off internal line pressure before opening the chamber.

  • Wear protective gloves and eye protection when handling trapped sharp metal shavings or rust debris.

8. FAQ Section

Q: What is the price of Y-Strainer 150 mm (6″) (Fiffco or equivalent) in Bangladesh?

A: Prices fluctuate based on flange standard, material grade, and order quantity. Contact loopshop.com.bd directly for the latest BDT quotation and project bulk pricing.

Q: Where can I buy Y-Strainer 150 mm (6″) in Bangladesh?

A: You can order the 150 mm (6″) Fiffco (or equivalent) Non-Listed Y-Strainer online from loopshop.com.bd with fast delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and all 64 districts of Bangladesh.

Q: What warranty does this product have?

A: This product is backed by Loop Engineering’s supplier quality assurance against manufacturing defects upon delivery. Contact our sales engineering team for project-specific warranty documentation.

Q: Is this suitable for the Bangladesh climate and water conditions?

A: Yes. It is specifically suited for Bangladesh’s humid plant rooms and water networks—including deep tube-well and underground reservoir supplies—where sand, silt, and pipe rust must be filtered before reaching pumps and valves.

Q: How to install this product?

A: Bolt the 150 mm flanges inline upstream of your pump or control valve, ensuring the body arrow aligns with water flow and the Y-pocket points downward for easy screen removal and sediment collection.

Q: What is the difference between a Non-Listed and a UL/FM Listed Y-Strainer?

A: A Non-Listed Y-strainer provides standard mechanical filtration without third-party UL/FM fire safety certification, making it ideal and economical for general water supply, HVAC, and local fire projects where UL/FM listing is not mandated by the buyer or consultant.

Q: Can the internal filter screen be cleaned and reused?

A: Yes. The perforated stainless steel basket is completely removable through the bolted cover, allowing you to wash out trapped debris and reuse the screen repeatedly.

Q: Where in a fire protection system should a 6-inch Y-strainer be placed?

A: It is typically installed on fire pump suction headers, ahead of Pressure Reducing Valves (PRVs), zone control valve assemblies, and alarm check valves to prevent debris from obstructing valve operation.

Q: Does Loop Engineering provide datasheets for client or consultant approval?

A: Yes. Technical datasheets and compliance submittals are available upon request when ordering through loopshop.com.bd.

Q: Do you offer installation support for 150 mm pipeline valves and strainers?

A: Yes. Loop Engineering provides end-to-end supply, installation, and commissioning support for industrial and commercial MEP and fire protection projects across Bangladesh.

Reviews

There are no reviews yet.

Be the first to review “Fiffco DN150 150 mm (6″) Flanged Y-Strainer Non-Listed for Fire & Water”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581