Shield SD-YS300FF-D 150 mm (6″) UL Y-Strainer for Fire Protection)

                  • Primary Purpose: Heavy-duty flanged Y-type mechanical strainer engineered to filter solid debris, rust, and pipe scale from fire protection and industrial water pipelines.

                  • Key Specifications: 150 mm (6-inch) nominal diameter, Model SD-YS300FF-D, UL Listed for certified fire safety compliance, with flanged end connections for secure inline mounting.

                  • Customer Benefits: Protects downstream fire pumps, sprinkler heads, alarm valves, and flow meters from clogging and mechanical damage while allowing fast screen blowdown maintenance.

                  • Bangladesh Market Relevance: Built to handle municipal water supply particulates, overhead tank sediment, and high-pressure firefighting mains in Bangladeshi garments factories, commercial towers, and industrial zones.

Best Price Guaranteed

Description

Product Overview

The Shield SD-YS300FF-D 150 mm (6″) UL Y-Strainer is a specialized inline pipeline filtration valve designed to remove unwanted solid particles from pressurized water systems. Featuring an angled “Y” leg housing an internal perforated or mesh strainer screen, it intercepts rust, welding slag, sand, and pipeline scale as water flows through the main bore, trapping debris inside the strainer basket without obstructing primary flow.

In Bangladesh, industrial facilities, RMG factories, and high-rise commercial developments frequently rely on deep tube wells, underground reservoirs, and municipal water networks that carry suspended particulates. Installing a UL Listed Y-strainer on fire pump suction lines, sprinkler risers, and main distribution headers is essential for MEP contractors, fire safety engineers, and facility managers to meet NFPA and local fire safety compliance standards.

Key Features

  • UL Listed Certification: Tested and certified to meet stringent fire protection industry standards for pressure integrity and operational reliability.

  • 150 mm (6-Inch) Flanged Ends: Standard flanged connections provide rigid, leak-free integration into heavy-duty 6-inch fire and industrial piping networks.

  • Angled Y-Body Design: Minimizes pressure drop across the valve while providing a dedicated chamber to collect solid debris out of the main flow path.

  • Removable Strainer Screen: Allows straightforward access to the internal filter element for periodic inspection, cleaning, and flushing without removing the valve body from the pipeline.

  • Corrosion-Resistant Coating: Engineered to withstand humid environments and continuous water exposure typical of fire pump rooms and mechanical shafts in Bangladesh.

Technical Advantages

  • High Flow Efficiency: The streamlined internal geometry reduces hydraulic turbulence and head loss, ensuring fire pumps and sprinkler systems receive adequate flow rates.

  • Equipment Protection: Prevents abrasive particles from damaging expensive fire pump impellers, pressure reducing valves, deluge valves, and sprinkler orifices.

  • Durable Heavy-Duty Construction: Built to endure continuous static pressure and water hammer surges common in pressurized fire protection mains.

  • Simplified Inline Maintenance: Servicing requires only isolating the line and opening the strainer cover, drastically reducing system downtime compared to inline basket filters.

Applications

  • Industrial & Factory: Garments (RMG), textile, pharmaceutical, and manufacturing plant fire hydrant and sprinkler pump rooms.

  • Commercial: High-rise office towers, shopping malls, hotels, and hospitals requiring UL Listed fire suppression components.

  • Project Installation: Turnkey MEP fire protection systems, municipal water pumping stations, and HVAC chilled water main lines.

  • Residential: Large-scale multi-tower apartment complexes with centralized fire-fighting water supply networks.

Why Choose This Product?

  • Certified Reliability: UL Listing gives project consultants, insurance auditors, and safety inspectors verified confidence in system compliance.

  • Consistent Hydraulic Performance: Engineered specifically for 150 mm (6″) fire mains where uninterrupted water delivery is critical during emergencies.

  • Long-Term Cost Effectiveness: Prevents costly fire pump repairs and blocked sprinkler heads, lowering total lifecycle maintenance expenses.

  • Local Supply & Support: Available through Loop Shop in Bangladesh with technical support for commercial and industrial project procurement.

4. Technical Specification Table

Specification Details
Model SD-YS300FF-D
Brand Shield
Rated Power Not Applicable (Mechanical Valve)
Voltage Not Applicable (Mechanical Valve)
Current Not Applicable (Mechanical Valve)
Frequency Not Applicable (Mechanical Valve)
Efficiency Low-pressure-drop Y-pattern hydraulic design
Protection UL Listed for fire protection service
Dimension 150 mm (6″) Nominal Pipe Size (Flanged)
Weight Refer to manufacturer datasheet
Operating Temperature Standard ambient & fire water service range
Warranty Manufacturer standard warranty (contact Loop Shop for terms)

5. Features List

  • UL Listed for certified fire protection systems

  • 150 mm (6″) nominal size with flanged end connections

  • Low-head-loss angled Y-strainer body design

  • Removable internal strainer screen for easy cleaning

  • Protects fire pumps, valves, and sprinklers from debris

  • Heavy-duty construction for high-pressure water mains

6. Benefits For Customers

  • Prevents Costly Equipment Damage: Stops sand, pipe scale, and construction debris from ruining fire pump impellers and control valves.

  • Ensures Fire System Readiness: Keeps sprinkler heads and hydrant nozzles clear of blockages during critical fire emergencies.

  • Reduces Maintenance Downtime: Enables rapid screen cleaning and debris blowdown without dismantling the main pipeline.

  • Built for Bangladesh Conditions: Handles sediment-heavy underground reservoir water and humid pump room environments reliably.

7. Installation & Maintenance Guide

Installation Requirements:

  • Install the strainer in the pipeline with the flow arrow cast on the valve body pointing in the exact direction of water flow.

  • For horizontal pipelines, position the Y-leg pointing downward so gravity collects debris inside the screen chamber.

  • Ensure adequate clearance below or around the strainer cover to allow complete removal of the filter screen during maintenance.

  • Align matching 150 mm (6″) flanges properly with appropriate gaskets and torque bolts evenly in a star pattern.

Maintenance Tips:

  • Inspect and clean the internal strainer screen after initial system flushing/hydro-testing, as new pipelines often carry welding slag and debris.

  • Establish a regular preventive maintenance schedule (quarterly or semi-annually) to flush accumulated sediment and inspect the screen for tears or corrosion.

  • Check the cover gasket during every screen cleaning and replace it if worn to prevent leaks.

Safety Instructions:

  • Always isolate the pipeline section and completely depressurize and drain the strainer before loosening cover bolts or blowdown plugs.

  • Wear appropriate personal protective equipment (safety glasses and gloves) when servicing pressurized water lines.

  • Verify all bolts and plugs are securely tightened before re-pressurizing the fire protection system.

8. FAQ Section

Q: What is the price of Shield Y-Strainer 150 mm (6″) SD-YS300FF-D in Bangladesh?

A: Pricing depends on order quantity, project requirements, and current import duties. Contact Loop Shop (loopshop.com.bd) directly for an updated BDT quotation or bulk project pricing.

Q: Where can I buy Shield Y-Strainer 150 mm (6″) SD-YS300FF-D in Bangladesh?

A: You can order online directly through loopshop.com.bd or contact Loop Engineering for corporate, factory, and MEP project supply across Dhaka, Gazipur, Chattogram, and nationwide.

Q: What warranty does this product have?

A: The Shield SD-YS300FF-D comes with standard manufacturer coverage against manufacturing defects. Please confirm specific warranty terms with Loop Shop at the time of purchase.

Q: Is this suitable for Bangladesh climate?

A: Yes. Its heavy-duty construction and protective exterior finish are well-suited for Bangladesh’s high humidity, monsoon conditions, and sediment-prone water supplies.

Q: How to install this product?

A: Mount the 150 mm flanged body inline with the flow arrow matching water direction and the Y-leg pointing downward on horizontal pipes, leaving enough space to pull out the strainer screen.

Q: Is the Shield SD-YS300FF-D UL Listed?

A: Yes, this model is UL Listed, making it compliant for certified fire protection systems in RMG factories, commercial buildings, and industrial projects.

Q: Where in a fire protection system should a 6-inch Y-strainer be installed?

A: It is typically installed on the suction or discharge side of fire pumps, upstream of alarm check valves, deluge valves, pressure reducing valves, and main sprinkler risers.

Q: Can this Y-strainer be installed in a vertical pipeline?

A: Yes, provided the water flows downward through the strainer so debris is trapped in the screen pocket rather than falling back into the upstream pipe.

Q: How often should the strainer screen be cleaned?

A: Clean it immediately after initial pipe commissioning, and follow a routine quarterly or semi-annual inspection schedule depending on local water sediment levels.

Q: Does Loop Shop provide technical documentation or submittals for project approval?

A: Yes, Loop Shop can assist MEP contractors and consultants with available product datasheets and UL compliance documentation for client submittals.

Reviews

There are no reviews yet.

Be the first to review “Shield SD-YS300FF-D 150 mm (6″) UL Y-Strainer for Fire Protection)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581