Description
Product Overview
The Shield SD-YS300FF-D 65 mm (2-1/2″) UL Listed Y-Strainer is a heavy-duty, flanged inline pipeline filtration device engineered specifically for fire protection and industrial water distribution networks. Installed upstream of sensitive mechanical equipment, it directs incoming water through an angled, perforated AISI 304 stainless steel mesh basket that traps foreign solids such as weld slag, sand, gravel, and pipe scale while maintaining smooth hydraulic flow.
This strainer is essential for MEP contractors, fire safety engineers, facility managers, and industrial plant owners. In Bangladesh—where RMG textile factories, pharmaceutical plants, and commercial towers undergo strict fire safety audits (such as RSC/Accord, NFPA, and Bangladesh Fire Service & Civil Defence inspections)—installing a UL Listed (EX16175) strainer ensures regulatory compliance and protects high-value fire pump sets from reservoir sediment.
Key Features
-
UL Listed Certification: Certified under UL File EX16175 for fire protection pipeline service, guaranteeing verified pressure integrity and hydraulic head-loss performance.
-
High-Strength Ductile Iron Body: Cast from ASTM A536 (Grade 65-45-12) ductile iron for superior tensile strength and resistance to hydraulic shock.
-
Corrosion-Resistant AISI 304 Screen: Equipped with a durable stainless steel perforated screen (4 mm hole diameter, 25 holes/in², 48% free flow area) that resists rust and deformation.
-
ANSI/AWWA C550 FBE Coating: Coated internally and externally with Fusion Bonded Epoxy (FBE) to prevent internal rust scaling and external atmospheric corrosion.
-
Standardized Flanged Connections: Machined to ASME B16.1 Class 125 flange dimensions (178 mm OD, 4 × 19.1 mm bolt holes) for seamless integration into standard fire pump headers.
-
Serviceable Bonnet & Bronze Drain Plug: Features a bolted ductile iron bonnet with an EPDM gasket and a threaded ASTM B584 bronze blowdown plug for quick flushing and screen removal.
Technical Advantages
-
Low Hydraulic Pressure Drop: Engineered with a 48% screen free-flow area, keeping head loss to approximately 4.18 PSI at 223.84 GPM so fire pump suction and discharge pressures remain within NFPA design limits.
-
Extended Equipment Lifespan: Eliminates abrasive particulate ingress into fire pumps, pressure-reducing valves (PRVs), deluge valves, and flow meters.
-
All-Weather Durability: Internal and external FBE protection prevents tuberculation and pitting caused by groundwater mineral content and monsoon humidity.
-
Rapid Inline Maintenance: Routine debris purging is completed via the bronze blowdown plug, while full screen inspection requires only unbolting the bonnet without removing the strainer body from the pipe run.
Applications
-
Industrial & RMG Factories: Fire pump suction/discharge headers, hydrant rings, and sprinkler risers in garment, textile, and manufacturing facilities.
-
Commercial Buildings: High-rise office towers, shopping malls, hospitals, and hotels requiring UL-compliant fire suppression networks.
-
Project Installations: Turnkey MEP fire protection contracts, central utility plants, and HVAC chilled-water pump protection.
-
Water Supply & Booster Systems: Municipal and industrial water transfer stations requiring coarse particulate filtration.
Why Choose This Product?
-
Verified Safety Compliance: Genuine UL Listing (EX16175) satisfies third-party safety auditors, insurance surveyors, and international buyer compliance teams.
-
Heavy-Duty 300 PSI Rating: Outperforms standard 175 PSI or 200 PSI strainers, providing a higher safety margin against pressure surges and water hammer.
-
Cost-Effective Asset Protection: A modest upfront investment prevents catastrophic failure and expensive downtime of UL/FM fire pumps and control valves.
-
Local Engineering Support: Supplied through loopshop.com.bd with local technical documentation, submittals, and project sourcing support across Bangladesh.
4. Technical Specification Table
| Specification | Details |
| Model | SD-YS300FF-D |
| Brand | Shield (Shield Fire Safety & Security Ltd.) |
| Nominal Size | 65 mm (2-1/2 Inch) |
| Certification | UL Listed (File No. EX16175) |
| Working Pressure | 300 PSI (20.7 Bar) |
| End Connection | Flanged to ASME B16.1 Class 125 |
| Body & Bonnet Material | Ductile Iron ASTM A536, Grade 65-45-12 |
| Screen Material & Mesh | Stainless Steel AISI 304 (4 mm hole dia., 25 holes/in², 48% free flow area) |
| Gasket & Plug Material | EPDM Gasket / Bronze Plug (ASTM B584) |
| Coating | Fusion Bonded Epoxy (FBE) Internal & External per ANSI/AWWA C550 |
| Dimensions (L × D × H) | Face-to-Face (L): 254 mm | Flange OD (D): 178 mm | Center-to-Bottom (H): 165 mm |
| Net Weight | 12.20 kg |
| Operating Temperature | 0°C to 80°C (with EPDM Rubber Gasket) |
| Warranty | 1 Year Manufacturer Warranty (Against Manufacturing Defects) |
5. Features List
✓ UL Listed (EX16175) for approved fire protection piping systems
✓ 300 PSI high-pressure rating with rugged ASTM A536 ductile iron body
✓ Corrosion-proof AISI 304 stainless steel perforated filter screen
✓ Internal & external ANSI/AWWA C550 Fusion Bonded Epoxy coating
✓ Standard ASME B16.1 Class 125 flanged ends for fast bolting
✓ Easy blowdown cleaning via threaded ASTM B584 bronze drain plug
6. Benefits For Customers
-
Protects Expensive Fire Pumps & Valves: Blocks stones, weld beads, and rust flakes from damaging pump impellers and fouling check valve seats.
-
Passes Fire Safety Audits: Meets international UL standards required by RSC/Accord, NFPA, and Bangladesh fire safety inspectors.
-
Minimizes Maintenance Downtime: Allows quick sediment flushing via the drain plug and rapid screen removal without cutting or unbolting main pipe flanges.
-
Built for Bangladesh’s Climate: FBE epoxy coating and stainless steel internals withstand high humidity, monsoon moisture, and mineral-rich water supplies.
7. Installation & Maintenance Guide
Installation Requirements:
-
Install upstream of the equipment being protected (such as fire pumps, PRVs, or alarm check valves) with sufficient clearance below the strainer leg to remove the screen.
-
Align the flow arrow cast on the ductile iron body strictly with the pipeline flow direction.
-
In horizontal pipelines, orient the strainer leg (bonnet) pointing straight downward so debris collects at the lowest point. In vertical pipelines, install only in downward-flowing lines.
-
Use compatible Class 125 flange gaskets and tighten flange bolts in a star pattern to ensure uniform sealing.
Maintenance Tips:
-
Flush the strainer periodically by opening the bronze blowdown plug (or a fitted blowdown ball valve) after initial system hydrostatic testing and during routine monthly fire pump inspections.
-
Monitor upstream and downstream pressure gauges; an abnormal pressure drop indicates screen clogging requiring manual cleaning.
-
During annual shutdowns, unbolt the bonnet, extract the AISI 304 screen, wash away trapped debris, inspect the EPDM gasket for wear, and reassemble.
Safety Instructions:
-
Never open the blowdown plug or unbolt the strainer bonnet while the pipeline is pressurized.
-
Isolate upstream and downstream gate valves and verify zero pressure on line gauges before performing any maintenance.
-
Wear appropriate PPE (safety glasses and gloves) during flushing and screen extraction.
8. FAQ Section
Q: What is the price of Shield Y-Strainer 65 mm (2-1/2″) SD-YS300FF-D in Bangladesh?
A: The price of the Shield SD-YS300FF-D 65 mm UL Listed Y-Strainer in Bangladesh depends on order volume, import duty fluctuations, and project requirements. Visit loopshop.com.bd or request an official B2B quotation for current retail and bulk project pricing in BDT.
Q: Where can I buy Shield SD-YS300FF-D Y-Strainer in Bangladesh?
A: You can order the genuine Shield SD-YS300FF-D 65 mm Y-Strainer online at loopshop.com.bd with delivery across Dhaka, Gazipur, Chattogram, Narayanganj, and industrial zones nationwide.
Q: What warranty does this product have?
A: It carries a standard 1-year warranty against manufacturing and casting defects when installed within its rated 300 PSI pressure and 0°C–80°C temperature limits.
Q: Is this suitable for Bangladesh climate?
A: Yes. The ductile iron body is coated internally and externally with Fusion Bonded Epoxy (ANSI/AWWA C550), and the filter screen is AISI 304 stainless steel, making it highly resistant to corrosion in Bangladesh’s humid and monsoon-prone climate.
Q: How to install this product?
A: Bolt the ASME B16.1 Class 125 flanges into the pipeline matching the flow direction arrow on the body, ensuring the strainer pocket faces downward in horizontal lines so trapped debris settles into the screen basket.
Q: Is the Shield SD-YS300FF-D approved for factory fire safety audits in Bangladesh?
A: Yes. It is UL Listed (File EX16175), meeting the fire protection equipment standards required by NFPA, RSC/Accord, and local fire safety authorities.
Q: What is the working pressure rating of the Shield SD-YS300FF-D?
A: It is rated for a maximum working pressure of 300 PSI (20.7 Bar), making it suitable for high-pressure fire pump discharge and riser networks.
Q: What material is the internal filter mesh made of?
A: The removable strainer screen is constructed from corrosion-resistant AISI 304 stainless steel with 4 mm perforations and a 48% free flow area.
Q: What flange standard does the SD-YS300FF-D use?
A: It features flat-face/raised-face flanged ends drilled to ASME B16.1 Class 125 (178 mm outer diameter, 139.5 mm bolt circle diameter, 4 × 19.1 mm holes).
Q: Can I clean the strainer without removing it from the pipeline?
A: Yes. Routine sediment can be flushed through the bottom bronze drain plug, and the entire stainless steel basket can be pulled out for thorough cleaning simply by unbolting the bonnet.

Reviews