FIFFCO 25mm (1″) Automatic Air Release Valve for HVAC & Fire Line

    • Continuous Air Elimination: Automatically vents trapped air pockets from pressurized water pipelines to prevent airlocks, pressure surges, and pump cavitation.

    • Heavy-Duty Specifications: Built with a 25 mm (1″) BSPT threaded inlet, anti-corrosion internal components, and PN16/PN25 working pressure ratings up to 120°C.

    • High System Efficiency: Protects pumps, valves, and heat exchangers from internal oxidation, flow restriction, and water hammer damage.

    • Engineered for Bangladesh: Ideal for high-rise fire hydrant risers, industrial chillers, and factory water networks across Dhaka, Gazipur, Chattogram, and Narayanganj.

Best Price Guaranteed

Description

Product Overview

What is this product?The FIFFCO 25 mm (1″) Automatic Air Vent / Air Release Valve (Non-Listed) is a precision hydronic and pipeline protection valve designed to continuously discharge entrained air and gas pockets from pressurized water systems.

How does it work? Installed at the highest points of a piping network, the valve houses an internal float mechanism. When air accumulates inside the valve chamber, the water level drops, causing the float to descend and open the discharge orifice. Once the trapped air escapes and water refills the chamber, the float rises and seals the orifice tightly against leakage.

Who needs this product? MEP contractors, HVAC engineers, fire protection installers, facility maintenance managers, and industrial plant operators rely on this valve to maintain stable hydraulic pressure and uninterrupted fluid circulation.

Why is it useful in Bangladesh? In Bangladesh’s rapidly growing high-rise commercial towers, garment factories, and industrial parks, long vertical risers and complex chiller loops frequently trap air during pump start-ups and refilling. Trapped air causes noisy pipes, accelerated internal pipe rusting, and pump dry-running. This valve automatically purges air without manual bleeding, ensuring reliable operation in humid, high-demand environments.

Key Features

  • 25 mm (1″) BSPT Threaded Connection: Standard 1-inch BSPT male inlet ensures fast, secure mounting on riser headers, manifolds, and air separators.

  • Anti-Corrosion Internal Trim: Specially treated internal parts resist rust, scale buildup, and mineral deposits from hard water.

  • High Venting Capacity: Large discharge orifice rapidly expels accumulated air pockets during system filling and continuous operation.

  • Bubble-Tight Shutoff: Precision-engineered internal seat and float assembly guarantee zero water leakage under pressurized conditions.

  • Wide Pressure & Temperature Tolerance: Rated for PN16 (16 bar) and PN25 (25 bar) working pressures and fluid temperatures from -10°C to +120°C.

Technical Advantages

  • Prevents Cavitation & Water Hammer: Eliminates compressible air pockets that cause destructive pressure spikes and impeller damage in centrifugal pumps.

  • Reduces Internal Corrosion: Removes oxygen-rich air from closed-loop HVAC and fire sprinkler/hydrant pipelines, extending pipework service life.

  • Zero Manual Intervention: Operates fully automatically 24/7, eliminating the labor cost and downtime of manual air bleeding.

  • Compact Vertical Profile: Fits easily inside tight ceiling voids, mechanical shafts, and pump room headers.

  • Easy Inline Servicing: Can be paired with a 1″ isolation ball valve underneath for quick inspection or cleaning without draining the main riser.

Applications

  • Commercial High-Rises: Domestic water booster risers, rooftop tank headers, and central air-conditioning (HVAC) chilled water loops.

  • Industrial & RMG Factories: Boiler feed lines, process cooling water networks, and compressed-water distribution headers.

  • Fire Protection Systems (Non-Listed): Wet riser top points and pump room discharge headers where non-listed ancillary air vents are specified.

  • HVAC & Chiller Plants: Fan coil unit (FCU) risers, air handling unit (AHU) coils, and heat exchanger high points.

  • Project Installations: Institutional buildings, hospitals, shopping malls, and municipal water supply networks.

Why Choose This Product?

  • Proven Engineering Reliability: Manufactured by FIFFCO to strict international hydrostatic testing standards (up to 1.5x working pressure).

  • Superior Hydraulic Performance: Maintains full pipe cross-section water flow, ensuring pumps and chillers operate at peak design efficiency.

  • Cost-Effective Asset Protection: A modest upfront investment prevents costly pump seal failures, corroded piping, and emergency plant shutdowns.

  • Trusted Local Support: Backed by Loop Engineering & Loop Shop Bangladesh for authentic sourcing, technical selection assistance, and project supply.

4. Technical Specification Table

Specification Details
Model FIFFCO Automatic Air Vent 25mm (PN16 / PN25 Series)
Brand FIFFCO
Nominal Size 25 mm (1 Inch)
Connection Type Male Threaded BSPT
Working Pressure 16 Bar (PN16) / 25 Bar (PN25)
Testing Pressure 24 Bar (PN16) / 37.5 Bar (PN25) — 1.5x Working Pressure
Suitable Media Water and Neutral Liquids
Internal Protection Anti-Corrosion Treated Internal Components
Certification Status Non-Listed (Standard Industrial / HVAC Grade)
Installation Orientation Vertical Upright (At Pipeline High Points)
Operating Temperature -10°C to +120°C
Warranty 1 Year Manufacturer Replacement Warranty (Against Manufacturing Defects)

5. Features List

  • ✓ Continuous automatic air release under full system pressure

  • ✓ Standard 25 mm (1″) BSPT male threaded inlet connection

  • ✓ Anti-corrosion treated internal float and mechanism

  • ✓ High air-venting capacity with drip-tight water shutoff

  • ✓ Hydrostatically tested to 1.5x rated working pressure

  • ✓ Rated for temperatures from -10°C up to +120°C

  • ✓ Compact, low-maintenance industrial construction

6. Benefits For Customers

  • Protects Expensive Pumps & Chillers: Eliminates air locking and cavitation, preventing premature mechanical seal and impeller burnout.

  • Improves Heat Transfer & Flow: Removes insulating air pockets in HVAC coils and risers so systems reach target cooling or pressure faster with less energy.

  • Extends Pipeline Lifespan: Reduces dissolved oxygen trapped at high points, slowing down internal rusting in MS and GI pipes used across Bangladesh.

  • Cuts Maintenance Labor: Eliminates the need for technicians to climb ladders or open ceiling panels to manually bleed air valves.

  • Built for Local Operating Conditions: Handles high-pressure booster pumps, rooftop tank fluctuations, and humid plant rooms reliably.

7. Installation & Maintenance Guide

Installation Requirements:

  • Location: Install strictly at the highest elevation points of the pipeline, riser headers, or air separators where air naturally collects.

  • Orientation: Mount in a strictly vertical, upright position so the internal float moves freely without binding.

  • Isolation Valve: Always install a 25 mm (1″) full-bore ball valve or gate valve directly below the air vent so it can be isolated for maintenance without draining the main line.

  • Thread Sealing: Apply PTFE thread seal tape or approved pipe sealant to the 1″ BSPT threads; tighten using a wrench on the valve hex base—never twist the upper body.

Maintenance Tips:

  • Periodic Inspection: Check the discharge outlet every 3 to 6 months for signs of mineral scale, debris, or moisture weeping.

  • Flushing: If debris from new pipework blocks the orifice, close the isolation valve, unscrew the upper cap/assembly, rinse the float and seat with clean water, and reassemble.

  • System Commissioning: Keep the isolation valve open during initial pipeline filling to allow rapid air evacuation.

Safety Instructions:

  • Depressurize Before Servicing: Always close the isolation valve and release residual pressure inside the vent chamber before disassembling.

  • High-Temperature Caution: In hot water or boiler loops operating up to 120°C, wear heat-resistant gloves and allow the valve body to cool before handling.

  • Media Compatibility: Use only with water and non-corrosive neutral liquids; do not install on hazardous chemical, steam, or fuel lines.

8. FAQ Section

Q: What is the price of FIFFCO 25 mm (1″) Automatic Air Release Valve in Bangladesh? A: The price of the FIFFCO 25 mm (1″) Automatic Air Vent / Air Release Valve in Bangladesh varies depending on the pressure rating (PN16 or PN25) and order quantity. Contact Loop Shop Bangladesh (loopshop.com.bd) for the latest retail and project quotation in BDT.

Q: Where can I buy FIFFCO Automatic Air Release Valve in Bangladesh? A: You can buy genuine FIFFCO 25 mm (1″) Automatic Air Release Valves directly online from loopshop.com.bd or through Loop Engineering’s corporate sales team in Dhaka, with nationwide delivery across Bangladesh.

Q: What warranty does this product have? A: This product comes with a 1-year warranty against manufacturing defects under standard operating pressure and temperature conditions.

Q: Is this suitable for Bangladesh climate? A: Yes. With anti-corrosion treated internal components and an operating range of -10°C to +120°C, it performs reliably in Bangladesh’s high humidity, monsoon conditions, and warm mechanical plant rooms.

Q: How to install this product? A: Install the valve vertically upright at the highest point of your pipeline or riser using its 25 mm (1″) BSPT threaded inlet, with a 1″ isolation ball valve underneath for easy future maintenance.

Q: What is the difference between a Non-Listed and UL/FM Listed Air Release Valve? A: A Non-Listed valve is built to standard industrial and HVAC engineering specifications (PN16/PN25) for water supply, chilled water, and general piping, whereas UL/FM Listed valves carry specific third-party certifications required for insured fire protection sprinkler systems.

Q: Can this 25 mm air vent be used in HVAC chilled water systems? A: Yes, it is specifically designed for HVAC chilled water risers, AHU/FCU headers, and closed-loop hydronic systems to prevent airlocks and improve heat transfer.

Q: What pressure rating is available for the FIFFCO 25 mm Automatic Air Vent? A: FIFFCO offers this 25 mm (1″) threaded automatic air vent in PN16 (16 bar working pressure) and PN25 (25 bar working pressure) configurations.

Q: Why is my automatic air release valve leaking water? A: Minor weeping usually occurs when pipe scale, welding slag, or dirt lodges between the internal float seat and orifice. Closing the isolation valve and flushing the internal chamber with clean water typically resolves the issue.

Q: Do I need an isolation valve underneath an automatic air vent? A: Yes, installing a 25 mm (1″) isolation ball valve beneath the air vent is standard MEP best practice so technicians can service or replace the vent without shutting down the entire building’s water or HVAC system.

Reviews

There are no reviews yet.

Be the first to review “FIFFCO 25mm (1″) Automatic Air Release Valve for HVAC & Fire Line”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581