NAFFCO Automatic Air Vent / Air Release Valve 25 mm (1″) NF-25ARV — UL/FM

        • Automatic Air Pocket Removal: Continuously vents trapped air from high points in pressurized fire protection pipelines and fire pump casings to maintain unobstructed hydraulic flow.

        • Heavy-Duty UL/FM Specifications: Features a 25 mm (1″) NPT inlet, 1/2″ NPT outlet, 1/16″ orifice, 175 PSI maximum working pressure, ductile iron ASTM A536 body, and corrosion-resistant Stainless Steel 316 float and internal trim.

        • System Protection & Positive Shut-Off: Equipped with an EPDM resilient orifice button and mechanical lever linkage that prevents water hammer, pipeline surges, and fluid leakage under high pressure.

        • Built for Bangladesh Industrial Compliance: Engineered to meet NFPA 20 standards and Accord/RSC fire safety requirements for RMG factories, commercial towers, and industrial pump rooms across Bangladesh.

        Built for Bangladesh Compliance: Engineered for high-humidity, dusty industrial environments and compliant with NFPA 13, NFPA 72, BNBC, and RSC/Nirapon fire safety audit standards in Bangladesh.

Best Price Guaranteed
SKU: GST DB-M01-2-2-1-1 Category Brand:

Description

Product Overview

The NAFFCO NF-25ARV 25 mm (1″) Automatic Air Release Valve is a UL Listed and FM Approved hydromechanical valve designed to automatically discharge accumulated air pockets from pressurized fire protection piping and fire pump casings.

Operating via an internal Stainless Steel 316 float and lever mechanism, the valve remains normally open when air is present. As water fills the chamber, the float rises and presses an EPDM orifice button against the seat to form a drip-tight seal. Whenever air collects at pipeline high points and enters the valve body, the water level drops, lowering the float and using mechanical lever advantage to open the 1/16″ orifice against line pressure so trapped air escapes smoothly.

MEP contractors, fire protection engineers, facility managers, and industrial plant owners in Bangladesh rely on this valve to keep fire pump headers and sprinkler mains primed and free of air locks. For RMG factories, pharmaceutical plants, and high-rise commercial buildings in Dhaka, Gazipur, Chattogram, and Narayanganj, installing an NFPA 20-compliant automatic air vent is essential for passing fire safety audits and preventing air-induced pressure surges during emergency pump startups.

Key Features

  • UL Listed & FM Approved: Certified for critical fire fighting and fire pump installations requiring international safety compliance.

  • Stainless Steel 316 Internal Trim & Float: Manufactured from ASTM A240 Grade 316 stainless steel for superior resistance against corrosion, scaling, and wear.

  • Ductile Iron Body & Cover: Constructed from heavy-duty ASTM A536 65-45-12 ductile iron finished with protective red epoxy coating.

  • Resilient EPDM Seating: Ensures tight, zero-leakage shut-off once air is evacuated and liquid fills the valve chamber.

  • High-Leverage Orifice Mechanism: Amplifies float weight so the 1/16″ orifice opens reliably even when the pipeline is pressurized up to 175 PSI.

  • Auxiliary Service Ports: Includes dedicated plugged ports for convenient flushing, testing, and draining during routine maintenance.

Technical Advantages

  • Maintains Full Hydraulic Capacity: Prevents air pockets from restricting pipe cross-sections, ensuring fire pumps and sprinkler risers deliver rated flow rates.

  • Surge & Water Hammer Prevention: Eliminates compressible air pockets that cause violent pressure spikes and unexplained pipe ruptures when pumps start or stop.

  • Corrosion-Resistant Durability: Full SS316 internal components and red epoxy-coated ductile iron withstand humid tropical plant rooms and untreated fire reservoir water.

  • Fail-Safe Mechanical Operation: Operates purely on buoyancy and line pressure—requiring zero external electrical power or control wiring.

  • Simplified Servicing: Top-entry bolted cover and auxiliary drain plugs allow rapid internal inspection without removing the valve body from the riser.

Applications

  • Industrial & Factory: RMG and textile mills, spinning factories, chemical plants, and pharmaceutical manufacturing facilities.

  • Commercial: High-rise office towers, shopping malls, hotels, hospitals, and corporate headquarters.

  • Fire Pump Rooms: Automatic fire pump casings and discharge headers per NFPA 20 guidelines.

  • Project Installation: High points of wet fire sprinkler mains, hydrant ring mains, and municipal or industrial water transmission pipelines.

  • Residential: Multi-story apartment complexes and gated residential towers with centralized fire fighting pump systems.

Why Choose This Product?

  • Proven International Reliability: Manufactured by NAFFCO (National Fire Fighting Manufacturing FZCO) under ISO 9001 quality systems with UL and FM certifications trusted by global fire safety auditors.

  • Consistent Live-System Performance: Unlike manual air vents that require operator intervention, the NF-25ARV continuously purges micro-bubbles and air pockets while the system remains pressurized.

  • Long-Term Cost Effectiveness: Protects expensive fire pumps from cavitation and shields piping networks from surge damage, dramatically lowering lifecycle repair expenses.

  • Local Supply & Engineering Support: Sourced through loopshop.com.bd with technical consultation, genuine documentation, and project-grade support in Bangladesh.

4. Technical Specification Table

Specification Details
Model NF-25ARV
Brand NAFFCO
Product Type Automatic Air Release Valve / Auto Air Vent (UL/FM Approved)
Nominal Valve Size 25 mm (1 Inch)
Inlet Connection 1″ NPT (Threaded, Vertical Bottom Inlet)
Outlet Connection 1/2″ NPT
Orifice Size 1/16″ (1.59 mm)
Maximum Working Pressure 175 PSI (12 Bar)
Body & Cover Material Ductile Iron ASTM A536 (Grade 65-45-12 / 64-45-12)
Float Material Stainless Steel 316 (ASTM A240)
Internal Trim / Seat Stainless Steel 316 (ASTM A240)
Orifice Button / Seal EPDM Resilient Seat
Gasket & Fasteners Non-Asbestos Gasket (CN-705), Alloy Steel SAE Grade 5 Cover Bolts
Exterior Finish Red Epoxy Painted
Approvals & Certifications UL Listed, FM Approved

5. Features List

  • ✓ UL Listed and FM Approved for fire protection systems

  • ✓ Heavy-duty ASTM A536 ductile iron body with red epoxy coating

  • ✓ Corrosion-proof Stainless Steel 316 float and internal trim

  • ✓ Resilient EPDM orifice button for bubble-tight shut-off

  • ✓ Rated up to 175 PSI maximum working pressure

  • ✓ 1″ NPT inlet and 1/2″ NPT outlet with 1/16″ precision orifice

  • ✓ Built-in auxiliary ports for testing, flushing, and draining

  • ✓ Automatic self-actuating design with zero power required

6. Benefits For Customers

  • Prevents Pump Air-Lock & Cavitation: Automatically bleeds trapped air from fire pump casings so pumps prime immediately and deliver full rated pressure during an emergency.

  • Protects Piping Against Surge Ruptures: Eliminates dangerous air pockets that amplify water hammer and cause joint leaks or pipe bursts.

  • Passes Fire Safety Inspections Smoothly: UL/FM certification and NFPA 20 alignment help factories and commercial buildings satisfy RSC, Accord, and Fire Service audit standards.

  • Zero-Maintenance Corrosion Resistance: SS316 internal parts resist rust and mineral buildup caused by humid conditions and local fire water tanks in Bangladesh.

7. Installation & Maintenance Guide

Installation Requirements:

  • Mount the valve strictly in a vertical upright position with the 1″ NPT inlet facing downward at the highest elevation points of the piping network or on the top of the fire pump casing.

  • Install a dedicated isolation stop valve (ball or gate valve) directly beneath the NF-25ARV inlet so the air release valve can be isolated for servicing without draining the main fire riser.

  • Connect a 1/2″ drain/vent line from the outlet port to an open floor drain or safe atmospheric discharge point, as minor liquid droplets may discharge right as the float closes.

  • Ensure adequate ventilation and drainage around the valve pit or pump room location.

Maintenance Tips:

  • Inspect the valve quarterly during routine fire pump and sprinkler riser checks to ensure the outlet orifice is clear of debris, paint, or insect nests.

  • Close the bottom isolation valve and open the auxiliary drain/flushing port periodically to flush out sediment or rust particles accumulated from the water supply.

  • Check the EPDM orifice button and cover gasket annually for wear or hardening and replace if seepage occurs during pressurized operation.

Safety Instructions:

  • Always close the underlying isolation valve and relieve internal pressure via the drain plug before unbolting the top cover.

  • Do not exceed the maximum rated working pressure of 175 PSI.

  • Never cap or plug the 1/2″ outlet vent port, as doing so disables automatic air release and creates an air-lock hazard.

8. FAQ Section

Q: What is the price of NAFFCO NF-25ARV 25 mm (1″) Automatic Air Release Valve in Bangladesh? A: The price of the NAFFCO NF-25ARV 1″ UL/FM Automatic Air Release Valve in Bangladesh varies depending on order quantity, project requirements, and current import duties. Contact loopshop.com.bd directly for the latest BDT unit price or bulk corporate quotation.

Q: Where can I buy genuine NAFFCO NF-25ARV Automatic Air Release Valve in Bangladesh? A: You can order genuine UL/FM approved NAFFCO NF-25ARV air release valves online from loopshop.com.bd, with delivery and technical engineering support across Dhaka, Gazipur, Chattogram, Narayanganj, and industrial zones nationwide.

Q: What warranty does this product have?A: The NAFFCO NF-25ARV is backed by manufacturer quality assurance against manufacturing defects, and its internal stainless steel float carries NAFFCO’s unconditional manufacturer guarantee. Contact loopshop.com.bd at the time of purchase for project warranty terms.

Q: Is this suitable for Bangladesh’s climate and industrial environment? A: Yes. With a heavy-duty red epoxy-coated ductile iron exterior and corrosion-resistant Stainless Steel 316 float and internal trim, it is specifically engineered to withstand high humidity, warm ambient temperatures, and untreated water in Bangladeshi factories and pump rooms.

Q: How do I install the NAFFCO NF-25ARV valve?A: Install the valve vertically (inlet down) at the highest point of your fire pipeline or pump casing using its 1″ NPT threaded connection, placing a manual isolation stop valve underneath it and routing the 1/2″ outlet to a safe drain.

Q: Is the NAFFCO NF-25ARV UL Listed and FM Approved?A: Yes, the NAFFCO NF-25ARV is both UL Listed and FM Approved, meeting strict international fire protection and NFPA 20 installation standards.

Q: What is the maximum pressure rating of the NF-25ARV?A: The valve is rated for a maximum working pressure (Max W.P.) of 175 PSI.

Q: Why is a 1″ automatic air release valve required on fire pumps?A: Under NFPA 20 standards, automatically controlled fire pumps require a listed float-operated air release valve (minimum 0.50″ / 12.7 mm nominal size) to automatically purge trapped air from the pump casing so the pump does not lose prime or suffer cavitation.

Q: What is the difference between NF-15ARV, NF-20ARV, and NF-25ARV? A: All three models share the same 175 PSI pressure rating, 1/16″ orifice, and 1/2″ NPT outlet, differing only in their inlet pipe connection sizes: NF-15ARV is 1/2″ (15 mm), NF-20ARV is 3/4″ (20 mm), and NF-25ARV is 1″ (25 mm).

Q: Does this valve require electricity to operate? A: No. It is a fully mechanical, buoyancy-operated float valve that opens and closes automatically based on water and air levels inside the chamber.

Reviews

There are no reviews yet.

Be the first to review “NAFFCO Automatic Air Vent / Air Release Valve 25 mm (1″) NF-25ARV — UL/FM”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581