Description
Product Overview
The Shield SDBLVT95 50 mm (2″) Ball Valve is a UL Listed quarter-turn isolation valve purpose-built for automatic fire sprinkler systems, inspector’s test connections, main drain lines, and fire pump auxiliary piping. Utilizing a precision-machined chrome-plated brass ball housed within reinforced PTFE seats, the valve transitions smoothly from fully open to drop-tight closed with a simple 90-degree turn of its lever handle. In Bangladesh—where garment factories, textile mills, commercial towers, and industrial warehouses must meet stringent UL/NFPA fire protection standards and pass regular safety audits—the Shield SDBLVT95 provides dependable flow control, compact pipe integration, and long-term corrosion resistance.
Key Features
-
UL Listed Certification: Tested and listed for fire protection service, ensuring compliance with international safety codes and industrial factory audits.
-
Forged Brass Body Construction: High-strength, dezincification-resistant forged brass body prevents cracking under high system pressure and water hammer surges.
-
Full-Port Waterway Design: Unobstructed 50 mm (2″) internal bore minimizes friction loss and allows unrestricted water discharge during drain and flow tests.
-
Quarter-Turn Lever Operation: Heavy-duty vinyl-insulated steel lever handle provides clear visual open/closed alignment and rapid 90-degree actuation.
-
Blowout-Proof Stem & PTFE Seats: Internal blowout-proof stem design with self-lubricating PTFE seats and double O-ring stem seals eliminates external leakage.
-
Threaded End Connections: Precision-cut 50 mm (2″) female threaded ends enable fast, leak-free installation on standard fire protection steel piping.
Technical Advantages
-
High Hydraulic Efficiency: Full-bore flow path matches the internal pipe diameter, preventing pressure drops across sprinkler test and drain lines.
-
Corrosion-Resistant Construction: Brass body and chrome-plated ball resist rust, mineral scaling, and galvanic degradation in damp pump rooms.
-
Superior Sealing Safety: Reinforced PTFE (Teflon) seats maintain bubble-tight shutoff even after long periods of static dormancy.
-
Compact Footprint: Space-saving threaded body fits easily into tight sprinkler riser manifolds, ceiling voids, and fire pump skids.
-
Maintenance-Free Service Life: Self-cleaning ball wipe action clears minor sediment during each cycle without requiring internal lubrication.
Applications
-
Industrial & RMG Factories: Sprinkler zone drain valves, inspector’s test connections, and fire pump auxiliary lines in garment and manufacturing plants.
-
Commercial Buildings: High-rise office towers, shopping malls, hospitals, and hotels requiring UL Listed fire suppression isolation components.
-
Residential Complexes: Multi-story apartment fire sprinkler risers, tank isolation lines, and booster pump manifolds.
-
Project Installations: EPC fire safety contracting, warehouse fire networks, and commercial MEP installations across Bangladesh.
Why Choose This Product?
-
Certified Audit Compliance: Genuine UL Listing satisfies strict compliance requirements for industrial fire safety inspections in Bangladesh.
-
Proven Reliability: Engineered specifically for high-pressure fire protection systems where instant, leak-free shutoff is critical.
-
Cost-Effective Durability: Heavy-duty forged brass resists corrosion and eliminates frequent valve replacements over the building’s lifespan.
-
Trusted Local Availability: Supplied through loopshop.com.bd with technical specification support and fast nationwide delivery across Dhaka, Gazipur, Chattogram, and Narayanganj.
================================================
4. Technical Specification Table
| Specification | Details |
| Model | SDBLVT95 |
| Brand | Shield |
| Product Type | Fire Protection Ball Valve |
| Certification | UL Listed |
| Nominal Size | 50 mm (2 Inch) |
| Connection Type | Female Threaded |
| Body Material | Forged Brass |
| Ball Material | Chrome-Plated Brass |
| Seat Material | Reinforced PTFE (Teflon) |
| Stem Design | Blowout-Proof Brass Stem with O-Ring Seals |
| Port Type | Full Port |
| Operation | Quarter-Turn Lever Handle |
| Application | Fire Sprinkler Drain, Test & Isolation Lines |
================================================
5. Features List
✓ UL Listed for certified fire protection service
✓ Heavy-duty forged brass body with chrome-plated ball
✓ Full-port 50 mm (2″) bore for minimal pressure drop
✓ Fast 90-degree quarter-turn lever handle operation
✓ Blowout-proof stem with leak-tight PTFE seats
✓ Compact female threaded ends for easy riser installation
================================================
6. Benefits For Customers
-
Hassle-Free Safety Audits: UL Listed certification ensures smooth approval during BNBC, NFPA, and factory fire safety inspections.
-
Instant Visual & Manual Control: Lever handle position immediately shows whether the valve is open (parallel to pipe) or closed (perpendicular to pipe).
-
Zero-Leakage Reliability: Double O-ring stem seals and PTFE seats prevent dripping in sensitive electrical and mechanical pump rooms.
-
Built for Bangladesh’s Climate: Solid brass construction resists rust and corrosion caused by high humidity and local water mineral content.
================================================
7. Installation & Maintenance Guide
Installation Requirements:
-
Flush the pipeline thoroughly before installation to remove pipe scale, metal shavings, or welding debris that could score the PTFE seats.
-
Apply UL-approved thread sealant or PTFE tape strictly to the male pipe threads—avoid getting excess tape inside the valve bore.
-
Use a wrench on the valve hex end closest to the pipe being threaded; never grip the opposite end or use the lever handle as a wrench.
-
Ensure adequate clearance around the valve body for a full 90-degree swing of the lever handle.
Maintenance Tips:
-
Inspect the valve periodically for external moisture around the stem packing and thread joints.
-
Cycle the valve through a full close-and-open 90-degree turn semi-annually (following proper sprinkler system impairment procedures) to keep the ball and PTFE seats clean.
-
Keep the vinyl-insulated handle clean and unobstructed for quick emergency access.
Safety Instructions:
-
Never leave a fire protection isolation ball valve in the closed position after testing or draining without immediate system restoration.
-
Do not apply excessive force or pipe extensions to the lever handle if resistance is felt; depressurize the line and inspect for debris.
-
Depressurize and drain the connected piping completely before removing the valve from service.
================================================
8. FAQ Section
Q: What is the price of Shield Ball Valve 50 mm (2″) SDBLVT95 in Bangladesh?
A: The price of the Shield SDBLVT95 50 mm (2″) UL Listed Ball Valve in Bangladesh depends on current stock and project order volume. Visit loopshop.com.bd or contact our sales team for the latest unit rate and bulk quotation.
Q: Where can I buy Shield Ball Valve 50 mm (2″) SDBLVT95 in Bangladesh?
A: You can purchase the genuine Shield SDBLVT95 50 mm (2″) UL Listed Ball Valve online at loopshop.com.bd, with fast delivery across Dhaka, Gazipur, Narayanganj, Savar, Chattogram, and industrial zones nationwide.
Q: What warranty does this product have?
A: The Shield SDBLVT95 Ball Valve comes with a manufacturer’s warranty against material and manufacturing defects. Check your official invoice from loopshop.com.bd for exact warranty coverage details.
Q: Is this suitable for Bangladesh climate?
A: Yes. Manufactured from corrosion-resistant forged brass with a chrome-plated ball and PTFE seats, it performs reliably in Bangladesh’s high-humidity pump rooms, coastal areas, and industrial environments.
Q: How to install this product?
A: Clean the pipe threads, apply approved thread sealant to the male pipe threads, thread the 50 mm (2″) valve onto the pipe by gripping the near-side hex flat with a wrench, and verify full 90-degree handle clearance.
Q: Is the Shield SDBLVT95 UL Listed for fire sprinkler systems?
A: Yes, the Shield SDBLVT95 is UL Listed specifically for fire protection applications, making it compliant for sprinkler drain lines, inspector’s test assemblies, and isolation points.
Q: Where is a 50 mm (2″) UL ball valve typically used in a fire fighting system?
A: A 50 mm (2″) UL Listed ball valve is most commonly installed on fire sprinkler main drain lines, zone control assemblies, inspector’s test connections, and fire pump sensing/auxiliary lines.
Q: How can I tell if the Shield SDBLVT95 ball valve is open or closed?
A: When the lever handle is aligned parallel with the pipeline, the valve is open; when the handle is turned 90 degrees perpendicular to the pipe, the valve is closed.
Q: What material is the Shield SDBLVT95 made of?
A: It features a heavy-duty forged brass body, a precision chrome-plated brass ball, a blowout-proof brass stem, and reinforced PTFE seats.
Q: Does this valve support full water flow without pressure restriction?
A: Yes, its full-port design matches the internal 50 mm (2″) pipe diameter, ensuring unobstructed flow and minimal pressure drop during system draining or testing.


Reviews