Maple Armor FW2733 Addressable Fire Suppression Maintenance Disconnect Switch (Stainless Steel)

• Service Safety Isolation: Physical key-operated disconnect switch that disables suppression release outputs during maintenance or testing
• NFPA 2001 Trapped-Key Security: Key can only be removed in the normal armed position to prevent accidental system bypass
• Stainless-Steel Construction: Premium brushed stainless-steel single-gang faceplate engineered for rugged industrial durability
• Visual Supervisory Diagnostic: Prominent yellow status LED illuminating steady when the releasing circuit is isolated or in trouble
• SLC Loop Addressing: Consumes 1 digital address supporting up to 252 points on Maple Armor loop circuits
• Multi-Box Mounting: Mounts semi-flush onto standard North American single-gang electrical junction boxes or surface boxes
• Certified Life-Safety Protection: Certified under UL 864 10th Edition, CAN/ULC-S527, and NFPA 2001 standards

Best Price Guaranteed

Description

The Maple Armor FW2733 Addressable Disconnect Switch is an intelligent life-safety maintenance interface engineered to isolate automated extinguishing circuits during routine testing, inspection, and servicing.

Operating seamlessly on the Signaling Line Circuit (SLC) of the Maple Armor FW2107 releasing panel, this switch occupies a single digital address. When turned to the disconnect position, it physically breaks the release path to preventing accidental solenoid tripping and gas discharge across protected data centers, server rooms, and battery storage halls.

Compliant with UL 864, CAN/ULC-S527, and NFPA 2001 standards, the Maple Armor FW2733 Addressable Disconnect Switch features a trapped-key mechanism where the service key can only be extracted when the system is in its normal armed state, ensuring facilities are never inadvertently left unprotected.

Technical Specifications Table

Product Model FW2733 (Series 2 Addressable Suppression Disconnect Switch)
Manufacturer & Brand Maple Armor Technologies Inc.
Country of Origin China
Switching Mechanism Key-operated physical rotary switch (Trapped key in Armed/Normal position)
Faceplate Construction Heavy-Duty Brushed Stainless Steel (Single-Gang profile)
SLC Operating Voltage 24 VDC Nominal (Operating Range: 13 to 28 VDC from SLC Loop)
Standby Current Consumption 0.15 mA @ 24 VDC
Active / Supervisory Current 0.27 mA @ 24 VDC
Diagnostic Status LED Front-facing Yellow LED (Indicates circuit disconnected / supervisory trouble)
SLC Address Consumption Occupies 1 digital address; supports up to 252 devices per loop
Programming Interface Electronic digital addressing via Maple Armor FW2411 Handheld Programmer
Compatible Control Panels Maple Armor Series 2 FW2107 Dual Hazard Agent Releasing Panel
Mounting Compatibility Standard North American single-gang electrical junction box or surface box
Field Wiring Terminals 18 AWG to 12 AWG (0.82 mm² to 3.31 mm²) captive screw terminal block
Dimensions & Weight 133.5 mm (L) × 98.5 mm (W) × 32 mm (H) | Approximate Weight: 220 g
Operating Environment 14°F to 131°F (-10°C to 55°C), 0% to 95% RH non-condensing (Indoor dry)
Regulatory Approvals UL 864 Listed, CAN/ULC-S527 Certified, NFPA 12/13/72/2001 Compliant

⚙️ Engineering & Architectural Resources

Verify maintenance isolation protocols, system supervisory reporting thresholds, and physical key management procedures in compliance with national NFPA 72 Fire Alarm Code Standards and NFPA 2001 Clean Agent Standards before commissioning.

Pair this disconnect switch with our compatible Maple Armor Fire Alarm Systems to build an integrated suppression network.

📥 Download Official Technical Submittal Sheet (FW2733-DS)

NFPA 2001 Trapped-Key Security & Safe Maintenance Isolation

The primary safety advantage of the Maple Armor FW2733 Addressable Disconnect Switch is its strict compliance with NFPA 2001 physical key safety mandates.

During routine fire alarm testing, air duct maintenance, or detector sensitivity calibration, accidental agent discharges can cause massive financial losses and life-safety hazards. Turning the key on the Maple Armor FW2733 Addressable Disconnect Switch safely disables the releasing circuit output while reporting a distinct supervisory trouble condition to the central FW2107 panel.

To eliminate human error, the physical key is physically trapped inside the switch cylinder while in the bypassed position. Technicians cannot extract the key until the switch is rotated back into the normal armed mode, ensuring building protection is immediately reinstated upon conclusion of maintenance tasks.

  • Fail-Safe Key Retention: Key cannot be removed while the suppression system is bypassed, preventing forgotten disconnections.
  • Brushed Stainless Steel Plate: Rugged, scratch-resistant metal faceplate provides clean aesthetics and long-term durability.
  • Distinct Yellow Supervisory LED: Provides instant visual indication when the system is isolated from the central panel.
  • Digital SLC Communication: Transmits supervisory trouble signals directly across the loop without needing auxiliary monitor modules.

Frequently Asked Questions (FAQ)

Q1: What is the primary function of the Maple Armor FW2733 Addressable Disconnect Switch?
A: The FW2733 is a key-operated safety switch used to temporarily disable and isolate clean agent suppression releasing circuits during testing, maintenance, or room servicing without putting the entire fire alarm panel out of commission.

Q2: Why can the key only be removed in the normal position?
A: In compliance with NFPA 2001 clean agent safety requirements, the key is trapped in the switch while in the “Disconnect” position to guarantee technicians physically re-enable and arm the suppression system before taking the key away.

Q3: How does the fire alarm panel respond when the switch is set to Disconnect?
A: The Maple Armor FW2107 control panel immediately registers a dedicated “Supervisory Trouble” event, alerting monitoring personnel that the suppression zone is manually bypassed, and illuminates the front yellow LED on the switch.

Q4: How many addresses does this disconnect switch consume on the SLC loop?
A: It occupies only one logical address on the Maple Armor Signaling Line Circuit (SLC) loop, supporting up to 252 total points per circuit.

Q5: What electrical backboxes are compatible with the FW2733 switch?
A: It mounts semi-flush onto standard North American single-gang electrical junction boxes or surface mounts using a standard single-gang metallic surface box.

Q6: Which fire alarm control panels are compatible with this disconnect switch?
A: The FW2733 is specifically designed for Maple Armor Series 2 control panels with agent releasing functionality, particularly the FW2107 dual-hazard releasing panel.

Reviews

There are no reviews yet.

Be the first to review “Maple Armor FW2733 Addressable Fire Suppression Maintenance Disconnect Switch (Stainless Steel)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support