Maple Armor FW2731 Addressable Manual Agent Release Station (Yellow / Form C Output)

• Dedicated Suppression Trigger: Purpose-built manual releasing station engineered for FM-200, Novec 1230, CO₂, and deluge clean agent systems
• High-Visibility Hazard Body: High-impact yellow thermoplastic enclosure with contrasting black text for instant identification
• Single-Action Initiation: Direct pull-down mechanical lever that immediately transmits an emergency agent discharge signal
• Auxiliary Form C Relay: Onboard 2A @ 24VDC dry contact configurable as Normally Open (NO) or Normally Closed (NC) via jumper
• Allen Key Reset Lock: Secure mechanical latching design easily restored using the included standard Allen service key
• SLC Loop Addressing: Consumes a single digital address supporting up to 252 devices on Maple Armor loop circuits
• Certified Life-Safety Protection: Fully listed under UL 38 and ULC-S528 standards and compliant with ADA mounting requirements

Best Price Guaranteed

Description

The Maple Armor FW2731 Manual Release Station is an intelligent, addressable manual initiating device designed specifically for gaseous and chemical fire suppression releasing applications.

Operating seamlessly on the Signaling Line Circuit (SLC) of the Maple Armor FW2107 releasing panel, this station consumes a single digital address to provide immediate manual agent discharge control for server rooms, critical data hubs, archives, and electrical switchgear vaults.

Compliant with UL 38 and ULC-S528 standards, the Maple Armor FW2731 Manual Release Station features a high-visibility yellow enclosure, an integrated Form C dry contact relay, and an Allen key-operated reset mechanism for authorized system restoration.

Technical Specifications Table

Product Model Maple Armor FW2731 (Series 2 Addressable Manual Agent Release Station)
Manufacturer & Brand Maple Armor Technologies Inc.
Country of Origin China
Operating Mechanism Single-Action Pull Down Lever (White lever with black lettering)
Enclosure Finish High-Impact Flame-Retardant Polymer (Yellow with black lettering)
SLC Operating Voltage 24 VDC Nominal (Operating Range: 13 to 28 VDC)
Standby Current Consumption 0.14 mA @ 24 VDC
Alarm Current Consumption 0.27 mA @ 24 VDC
Auxiliary Dry Contact 1 Form C Output rated 2.0 A @ 24 VDC (Jumper-selectable NO/NC)
Reset & Testing Method Allen Key mechanical reset lock (Allen service tool included)
Status Diagnostic Indicator Front-facing LED (Flashes every 4 seconds in standby / Steady red on alarm)
SLC Address Loading Occupies 1 digital address; supports up to 252 devices per loop
Programming Method Electronic addressing via Maple Armor FW2411 Handheld Programmer
Compatible Control Panels Maple Armor Series 2 FW2107 Dual Hazard Agent Releasing Panel
Field Wiring Terminals 18 AWG to 12 AWG (0.82 mm² to 3.31 mm²) captive screw terminals
Dimensions & Weight 95 mm (L) × 130 mm (W) × 63.5 mm (H) | Weight: 320 g (with base)
Operating Environment 14°F to 131°F (-10°C to 55°C), 0% to 95% RH non-condensing (Indoor dry)
Regulatory Listings UL 38 Listed, ULC-S528 Certified, NFPA 12/13/72/2001, ADA Compliant

⚙️ Engineering & Architectural Resources

Verify manual discharge abort circuits, pre-discharge warning delays, and emergency exit door proximity in accordance with national NFPA 72 Fire Alarm Code Standards and NFPA 2001 Clean Agent Standards before installing releasing pull stations.

Pair this station with our complete lineup of Maple Armor Fire Alarm Systems to complete your clean agent suppression layout.

📥 Download Official Technical Submittal Sheet (FW2731-DS)

High-Visibility Suppression Control & Configurable Auxiliary Output

The primary design advantage of the Maple Armor FW2731 Manual Release Station is its distinct high-visibility yellow housing.

In facilities equipped with both general fire alarm pull stations and dedicated clean agent suppression systems, standard red pull boxes can lead to confusion. The bright yellow finish immediately signifies chemical suppression release, ensuring operators do not trigger gaseous extinguishing agents accidentally during general evacuation situations.

When the lever is pulled down, the station latches mechanically in the alarm position and sends an instant priority signal across the SLC. Simultaneously, the onboard Form C dry contact can be used to locally trip auxiliary warning bells, close ventilation dampers, or drop magnetic door holders before the extinguishing agent is discharged into the protected space.

  • Distinct Yellow Enclosure: Visually differentiates clean agent release controls from standard building fire alarm pull stations.
  • Direct Single-Action Lever: Pull-down lever provides rapid manual actuation during critical high-heat industrial emergencies.
  • Configurable Dry Contact: Jumper-selectable NO/NC auxiliary relay switches external equipment up to 2A @ 24VDC.
  • Allen Key Latch Reset: Mechanical latch remains locked in the active position until authorized staff reset it with the included Allen tool.

Frequently Asked Questions (FAQ)

Q1: What suppression systems can be controlled with the Maple Armor FW2731 Manual Release Station?
A: The Maple Armor FW2731 is designed to trigger all standard extinguishing systems, including FM-200, Novec 1230, CO₂, Inergen, Argonite, and pre-action deluge systems.

Q2: Why is this manual station yellow instead of standard red?
A: In accordance with NFPA life-safety standards, yellow enclosures are designated for gaseous and clean agent suppression releasing systems to distinguish them from general red building fire alarm pull stations.

Q3: How is the pull station reset after being activated?
A: The station features an Allen key reset lock. Authorized personnel insert the included Allen key into the front reset port to unlock the mechanism and return the pull handle to its normal upright position.

Q4: How does the onboard auxiliary dry contact function?
A: The station includes an isolated Form C relay rated at 2A @ 24VDC. A small jumper switch on the backplate allows installers to configure the contact as Normally Open (NO) or Normally Closed (NC) to control local dampers or auxiliary warning devices.

Q5: What electrical backboxes are compatible with the FW2731?
A: It mounts semi-flush onto standard North American single-gang electrical junction boxes or surface mounts using a compatible deep yellow surface backbox.

Q6: Which fire alarm control panels support the Maple Armor FW2731 manual release station?
A: It is engineered specifically for Maple Armor Series 2 control panels with agent releasing capability, particularly the FW2107 dual-hazard releasing panel.

Reviews

There are no reviews yet.

Be the first to review “Maple Armor FW2731 Addressable Manual Agent Release Station (Yellow / Form C Output)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581