Description
The Generator Automatic Voltage Regulator AVR master series delivers high-precision closed-loop excitation control, rapid transient voltage recovery, and fail-safe alternator protection for industrial diesel generator sets and prime power plants. Covering industry-standard configurations—including Stamford models (AS440, AS480, AS540, SX460, SX440, MX321, MX341), Leroy Somer units (R150, R220, R230, R250, R438, R448, R449, R450, R450M), Mecc Alte regulators (SR7, UVR6), Marelli Motori (M16FA655A, M40FA640A), and universal brushless modules (GAVR-12A, GAVR-15A/C, GB160/170, SE350)—this comprehensive suite maintains clean, ripple-free AC output within ±0.5% to ±1.0% RMS regulation accuracy across commercial facilities in Bangladesh.
Technical Specifications Table
| Product Category | Generator Automatic Voltage Regulator AVR Master Range |
| Supported AVR Models | Stamford AS440 / AS480 / AS540 / SX460 / MX321 / MX341 | Leroy Somer R450 / R448 / R449 / R438 / R250 / R230 / R150 | Mecc Alte SR7 / UVR6 | Marelli M40FA640A / M16FA655A | GAVR 12A / 15A / 15C | SE350 |
| Excitation System Support | Self-Excited SHUNT | Auxiliary Winding (AREP) | Permanent Magnet Generator (PMG) | Harmonic Excitation |
| Sensing Input Voltages | Single-Phase or 3-Phase: 95V–132V AC / 190V–264V AC / 340V–520V AC (50/60 Hz Jumper Selectable) |
| Power Supply Inputs | 170V to 277V AC (1-Phase or 3-Phase PMG / Auxiliary Winding System) |
| Continuous DC Output Current | 3.0A to 10.0A DC Continuous (Forcing Capability: Up to 15.0A–16.0A DC for 10 Seconds) |
| Max DC Excitation Output Voltage | Max 30V DC (Marelli M16), 63V–90V DC (Stamford/Leroy Somer), 120V DC (MX321 High Output) |
| Voltage Regulation Accuracy | ±0.5% to ±1.0% RMS with 4% Engine Governing |
| Under-Frequency Protection | Integrated UFRO Knee-Point (Preset at 47 Hz for 50 Hz Systems / 57 Hz for 60 Hz Systems) |
| Load Acceptance & Paralleling | Load Acceptance Module (LAM) & Quadrature Droop CT Input for Alternator Paralleling |
| Enclosure & Operating Temp | Resin-Potted Flame-Retardant Polyurethane Enclosure (-40°C to +70°C Engine Bay Class) |
| Warranty Coverage | 12-Month Standard Manufacturer Replacement Warranty |
&gear; Engineering & Technical Compatibility Verification
Verify field coil resistance, excitation source (SHUNT vs. PMG), and sensing transformer ratios prior to installing your Generator Automatic Voltage Regulator AVR. Learn more about Automatic Voltage Regulator Control Architecture for technical standards validation.
Excitation Topologies & Generator Load Stabilization
In power generation systems, load switching from heavy electric motors, HVAC chillers, and industrial drives causes sudden voltage dips. The Generator Automatic Voltage Regulator AVR functions by constantly monitoring the alternator’s AC terminal voltage and instantly adjusting DC current supplied to the stationary exciter field. This controls the rotating magnetic field on the main rotor, maintaining terminal voltage stability during sudden step-load applications.
For standard installations, self-excited SHUNT regulators (such as Stamford AS440, SX460, and Leroy Somer R250) provide cost-effective voltage regulation. For heavy industrial installations with non-linear loads and harmonic distortion, PMG-powered models (such as Stamford MX321, MX341, and Leroy Somer R450) isolate the AVR power circuits from the main output windings, guaranteeing sustained short-circuit clearance current and stable motor starting. Installing a genuine Generator Automatic Voltage Regulator AVR eliminates voltage flickering, prevents alternator overheating, and protects sensitive facility equipment across Bangladesh.
- Precise Output Regulation: The Generator Automatic Voltage Regulator AVR maintains steady voltage within ±0.5% RMS across complete no-load to full-load cycles.
- Universal Compatibility: Direct fit for alternators across Stamford, Leroy Somer, Mecc Alte, Marelli Motori, Marathon, and brushless ST platforms.
- Under-Frequency Roll-Off: Built-in UFRO circuit reduces excitation output if engine RPM drops, protecting the alternator from low-speed over-excitation.
- Parallel Operation Ready: Quadrature droop inputs allow balanced reactive kVAR load sharing between multiple paralleled generators.
- Reduced Operating Costs: Prevents electrical equipment damage from transient overvoltage surges and ensures reliable excitation field life.
Frequently Asked Questions (FAQ)
Q1: What is the price of a Generator Automatic Voltage Regulator AVR in Bangladesh?
A: Pricing depends on the specific AVR model, excitation topology (SHUNT, AREP, or PMG), and brand (Stamford AS440, Leroy Somer R450, Mecc Alte UVR6, or GAVR-15A). Contact our technical sales engineering team at Merlin Tech Ltd directly for an official quotation on each Generator Automatic Voltage Regulator AVR.
Q2: What is the difference between a SHUNT AVR and a PMG AVR?
A: A SHUNT AVR draws its operating power directly from the alternator output terminals, which can collapse during heavy short-circuit or motor starting surges. A PMG AVR draws independent power from a permanent magnet generator mounted on the alternator shaft, ensuring isolated power supply and sustained 300% short-circuit current.
Q3: How does the Generator Automatic Voltage Regulator AVR protect the alternator during engine slowdown?
A: The AVR features Under-Frequency Roll-Off (UFRO). When engine speed drops below its preset knee-point (47 Hz for 50 Hz systems), the AVR reduces output voltage proportionally with frequency to prevent exciter stator overheating.
Q4: Can a single-phase AVR be used on a three-phase generator?
A: Yes, many standard regulators (such as Stamford AS440 or Leroy Somer R250) use single-phase sensing across two phase lines (line-to-line 220V–240V or 380V–415V) to regulate three-phase output on balanced loads.
Q5: What causes an alternator to lose its residual magnetism (fail to build voltage)?
A: If a generator has been idle for a long period or has undergone stator maintenance, residual magnetism in the exciter core may drop below 4V–5V AC. Flashing the field briefly with a 12V DC battery restores residual magnetism so the Generator Automatic Voltage Regulator AVR can build voltage automatically.
Q6: Where can I buy genuine Stamford, Leroy Somer, and Mecc Alte AVRs in Bangladesh?
A: You can purchase 100% authentic Stamford, Leroy Somer, Mecc Alte, Marelli, and industrial OEM Generator Automatic Voltage Regulator AVR modules directly from Merlin Tech Ltd with full warranty backing.






Reviews
There are no reviews yet.