Perkins Engine Stop Solenoid | Fuel Shut-Off Series (22 kVA to 900 kVA)

• Genuine Perkins OEM Engine Shutdown Defense: Heavy-duty 12V DC fuel shut-off and stop solenoids for industrial diesel generators
• Multi-Range Generator Power Support: Engineered for compact 22 kVA, standard 30 kVA, up to heavy-duty 900 kVA power plants
• Consolidated Part Coverage: Unifies models U85206452 (400 Series 2-pin), 26420472 (1100 Series screw-in), and 589/91 / 923-026 (4000 Series bracket pull)
• Instant Emergency Fuel Cut-Off: Shuts off fuel injection flow within milliseconds upon overspeed, low oil pressure, or high temperature trips
• Rugged Coil & Return Spring: High-grade environmental plating and heavy-duty spring resist thermal fatigue and diesel fuel corrosion
• Direct Cross-Reference Support: Compatible with FG Wilson 923-026 / 589-91, Woodward 2370 series, CAT 233-6648, and Delphi injection pumps

Best Price Guaranteed

Description

The Perkins Engine Stop Solenoid series delivers rapid, dependable fuel cut-off and emergency shutdown protection for Perkins diesel generator engines and heavy equipment. Consolidating essential direct-fit models (including U85206452, 26420472, and 589/91 / 923-026), this product group covers generator applications from compact 22 kVA units up to high-capacity 900 kVA industrial power installations. By integrating high-pull electromagnetic coils, precision-machined plungers, and robust internal return springs, each solenoid ensures instantaneous fuel regulation and failsafe engine shutdown across commercial and industrial facilities in Bangladesh.

Technical Specifications Table

Product Series Perkins Engine Stop Solenoid Series
Consolidated Part Numbers U85206452, 26420472, 589/91, 923-026 (923026)
Brand Compatibility Perkins Engines / FG Wilson / Caterpillar / Delphi
Operating Voltage 12 Volt DC Standard (with 24V options for 4000 series systems)
Engine Series Compatibility Perkins 400, 1100 & 4000 Series Engines
Supported Engine Models 403C-15, 404C-22, 404C-22T, 1103A-33, 1104A-44, 4006, 4008, 4012, 4016
Generator Power Range 22 kVA, 30 kVA, 60 kVA, up to 900 kVA Heavy Power Plants
Cross-Reference Part Numbers Woodward 2370-24E6U1B5S2AD, CAT 233-6648, 185206452, Delphi 7185-900G
Electrical Connection Formats 2-Pin Weatherproof Pigtail (400 Series), Screw Terminals & Blade Connectors
Internal Construction High-Conductivity Copper Windings, Corrosion-Resistant Plating & Viton Seals
Warranty Coverage 12-Month Standard Manufacturer Replacement Warranty

⚙️ Engineering & Technical Compatibility Verification

Verify coil operating voltage, injection pump mounting thread dimensions, and linkage stroke lengths prior to installing the Perkins Engine Stop Solenoid. Review official guidelines at Perkins Engines Official Portal for technical verification.

📩 Request Part Verification & Pricing Quote

Instantaneous Fuel Isolation & Failsafe Generator Safety

Modern diesel generators rely on automated engine control modules to monitor vital operating parameters like coolant temperature, oil pressure, and alternator output frequency. In the event of a sudden thermal surge or loss of oil pressure, the Perkins Engine Stop Solenoid instantly de-energizes or actuates the mechanical fuel rack, starving the combustion chambers of fuel and stopping the engine within a fraction of a second to prevent catastrophic structural seizure.

Operating generators with sluggish or degraded solenoids can lead to dangerous engine runaway conditions or persistent cranking without ignition. Genuine Perkins fuel shut-off solenoids feature thermal-resistant insulated wire windings and precision ground plungers that resist fuel varnish buildup. Whether installed directly into a Delphi rotary fuel pump or mounted as a linkage actuator on a large 4000 Series governor lever, these solenoids provide absolute operational reliability across power plant installations in Bangladesh.

  • Rapid Emergency Fuel Cut-Off: Shuts down diesel fuel supply instantly upon receiving fault signals from the generator control panel.
  • Heavy-Duty Pull & Hold Coils: Engineered for continuous duty without overheating or thermal coil burnout during extended runtimes.
  • Corrosion-Proof Plating: Environmental plating and Viton elastomeric seals resist degradation from diesel fuel and moisture.
  • Direct OEM Alignment: Exact mounting threads and electrical pin terminals ensure fast, seamless field replacement.
  • Guaranteed Engine Protection: Prevents catastrophic engine failures by ensuring positive fuel shut-off under all emergency conditions.

Frequently Asked Questions (FAQ)

Q1: What is the official price of the Perkins Engine Stop Solenoid in Bangladesh?
A: Solenoid pricing varies depending on generator rating (22 kVA compact units vs 900 kVA heavy industrial pull-type models). Please contact our sales desk for an official quote on your required part number.

Q2: Which Perkins stop solenoid fits a 22 kVA generator?
A: The 22 kVA Perkins 400 Series engines (403C-15, 404C-22) utilize part number U85206452 (or 185206452), which features a 2-pin wiring lead and screw-in stem.

Q3: Which solenoid is designed for 30 kVA Perkins engines?
A: The 30 kVA Perkins 1100 Series engines commonly use part number 26420472, a direct screw-in rotary pump solenoid with spade electrical terminals.

Q4: When is the 589/91 or 923-026 stop solenoid required?
A: The 589/91 (923-026) external linkage pull solenoid is engineered for large Perkins 4000 Series engines (4006, 4008, 4012, 4016) used in heavy-duty generator sets up to 900+ kVA.

Q5: What are the common symptoms of a failing fuel stop solenoid?
A: Symptoms include an engine that cranks but will not start (solenoid failed to pull open), an engine that fails to shut down after turning off the key/controller, or random unexpected engine stalling.

Q6: Where can I source authentic Perkins generator stop solenoids in Bangladesh?
A: You can purchase 100% authentic Perkins stop solenoids, fuel pumps, sensors, and electrical components directly from our inventory with comprehensive warranty backing.

Reviews

There are no reviews yet.

Be the first to review “Perkins Engine Stop Solenoid | Fuel Shut-Off Series (22 kVA to 900 kVA)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581