Simplex 4100-5102 XPS Expansion Power Supply Card

• Global Brand Alignment: Simplex Portfolio by Johnson Controls
• Manufacturing Origin Profile: Mexico
• International Input Filtering: Engineered exclusively for 220/230/240 VAC, 50/60 Hz power infrastructures
• Substantial Output Capacity: Supplies up to 9 Amps of total DC output power across expansion bay card loops
• High-Current Circuit Delivery: Provisions 3 built-in Notification Appliance Circuits rated at 3 Amps each
• Dual-Configuration Wiring: Supports secure hardwired Class A loop returns or T-tapped Class B field paths
• System Coverage Scaling: Expands from 3 to 6 active circuits via the 4100-5115 option card module
• Proactive Terminal Supervision: Integrated short-circuit logic de-energizes loops automatically upon fault detection

Best Price Guaranteed

Description

The Simplex 4100-5102 XPS Card is an essential, high-performance expansion power supply module engineered to deliver secondary current routing, signal stabilization, and expanded circuit capacity to Simplex 4100U and 4100ES fire alarm control panels. Operating on an international high-voltage main input line, this flat-design internal module delivers supplemental current directly to high-draw notification runs and option card slots across your network. By packing advanced line monitoring filters and automated fault-detection parameters onto a single block chassis, the Simplex 4100-5102 XPS Card delivers an outstanding booster power foundation for demanding commercial, institutional, and industrial real estate complexes.

Technical Specifications Table

Model Assignment 4100-5102 (XPS Expansion Power Supply Module)
Manufacturer Family Intelligent Panel Base Hardware by Simplex (Johnson Controls)
Country of Origin Mexico
Mains Input Power 220 / 230 / 240 VAC (+10% / -15% tolerance limits), 50/60 Hz frequency range
Maximum AC Line Current 2.0 Amps maximum current draw under full master panel load variables
DC Output Voltage Boundaries Minimum: 19.5 VDC | Maximum: 32 VDC nominal output threshold window
Total Power Current Capacity 9.0 Amps total continuous duty capacity across all internal card operations
Notification Loop Outputs 3 Supervised Notification Appliance Circuits (NACs) built natively on the board
Circuit Load Capacity 3.0 Amps maximum per individual circuit | Supervised reverse-polarity logic
Regulated 24V Current Rating 4.0 Amps maximum current available concurrently across the 3 circuit lines
Auxiliary Output Configuration Each circuit is independently software programmable as a 2.0 Amp auxiliary tap
Visual Diagnostic Indicators 1 Green AC status LED | 3 Yellow active circuit LEDs | 2 Trouble LEDs
Module Space Allocation Occupies exactly 2 vertical block mounting spaces on the expansion backplane PDI
Operating Temperature 32°F to 120°F (0°C to 49°C) certified strictly for indoor panel bay installations
Relative Humidity Limit Up to 93% RH non-condensing moisture boundaries at 90°F (32°C)
Agency List Compliance UL 864 Listed, ULC Listed, FM Approved, CSFM Certified, NYC MEA Accepted

⚙️ Engineering & Architecture Resources

Verify system voltage drop margins, Class A circuit constraints, and expansion bay power distribution variables in accordance with national NFPA 72 Fire Alarm Code Standards before executing loop terminals configuration for the Simplex 4100-5102 XPS Card infrastructure.

📥 Download Official Technical Manual (574-772)

Flexible SmartSync Signaling & Proactive Circuit Supervisory Safeguards

The defining engineering benefit of integrating the comprehensive Simplex 4100-5102 XPS Card into an expansion bay chassis is its advanced signaling line flexibility. Every on-board notification circuit can be configured to operate under two distinct structural power profiles: Regulated 24 VDC mode or Special Application mode. When programmed for Special Application signaling, the loops unlock full capacity to drive and synchronize large rows of non-addressable sirens, visual strobes, and combination horn-strobes across adjacent panel modules. This non-pulsing, linear output design maintains strict light and tone synchronization across widespread facility zones, ensuring clear emergency notification while maintaining code compliance.

Furthermore, because the card interfaces directly via a standard Power Distribution Interface (PDI) connection, it provides exceptional system stability and real-time wire monitoring. The internal circuit logic actively supervises terminal blocks for open circuits, short circuits, and dangerous ground fault anomalies down to a 10k Ohms minimum threshold window. If a short-circuit fault manifests down the line, the card instantly isolates and de-energizes that single affected terminal path to protect the panel’s internal components while keeping the other output lines completely functional. Deploying the Simplex 4100-5102 XPS Card booster link inside an enclosure gives engineering teams the upper hand during demanding property retrofits.

Beyond traditional distribution, the structural layout of the Simplex 4100-5102 XPS Card is fully protected against electromagnetic line noise and voltage surges. This localized protection keeps communication commands stable and clean even when routed through shared high-voltage risers or complex mechanical utility spaces. The system constantly monitors internal power distribution balances across the expansion bay infrastructure, dynamically adjusting current routing variables to ensure maximum performance from every single option card and signaling loop connected to the sub-panel.

  • Dual-Configuration Branch Routing: Natively handles secure loop-return Class A configurations to protect lines against single open faults, as well as T-tapped Class B paths to save field material costs.
  • Daughter-Card Option Scalability: Card frame is pre-built with dedicated connection header plugs to mount a 4100-5115 module, seamlessly increasing total circuit output from 3 to 6 channels.
  • Programmable Auxiliary Voltage: Allows any open circuit line to be converted into a continuous 2.0 Amp auxiliary power tap to drive relays, door holders, or four-wire smoke heads.
  • Base-Mounted Address DIP Switches: Uses an 8-position binary DIP switch configuration block to map the card address inside the panel programming software before final hardware installation.

Frequently Asked Questions (FAQ)

Q1: What is the primary functional difference between the 4100-5102 card and a standard panel power supply?
A: The 4100-5102 acts strictly as a supplemental booster supply for option slots and signaling circuits inside expansion bays, and it does not contain battery charging circuitry on the board.

Q2: Can this specific booster module be wired to standard American 120 VAC main lines?
A: No. The 4100-5102 model variant is manufactured with transformers engineered exclusively to handle high-voltage international 220/230/240 VAC input grids.

Q3: How many total circuit channels can this expansion card support if fully expanded?
A: The card contains 3 notification circuits natively, which can be expanded to 6 independent circuits by plugging a 4100-5115 expansion daughter card module directly onto the board header.

Q4: What happens to the module outputs if a field circuit undergoes a direct short circuit?
A: The board detects the overcurrent threshold immediately and de-energizes that single shorted circuit branch to protect the panel’s internal components while keeping the other output lines completely functional.

Q5: What is the maximum load rating allowed across the entire module terminals assembly?
A: The overall capacity is 9.0 Amps maximum, which must include the combined current drawn by the notification loops, auxiliary power taps, card power, and any modules sharing the same bay.

Q6: Does this expansion card require an external end-of-line resistor if a circuit branch is left unused?
A: Yes. Any unused circuit line on the terminal block must be fitted with a standard 10k Ohm, 1/2 Watt brown/black/orange factory-installed end-of-line resistor harness to prevent an open fault code at the panel.

Q7: What is the verified country of manufacturing origin for this life-safety component?
A: This genuine fire panel replacement board is built to strict international safety and quality control parameters in Mexico.

Reviews

There are no reviews yet.

Be the first to review “Simplex 4100-5102 XPS Expansion Power Supply Card”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581