Simplex 4100-5313 EPS Card Master Controller Bay Assembly

• Global Brand Alignment: Simplex Portfolio by Johnson Controls
• Manufacturing Origin: Mexico
• Complete Bay Architecture: Integrates a 32-bit master processor panel, liquid crystal display, and core power network
• Input Grid Rating: Purpose-built for 240 VAC international voltage infrastructures
• Regulated Intelligent Power: Supplies a constant, switching 29 VDC line output even during battery standby backup
• Integrated Loop Module: Pre-fitted with a 250-point addressable IDNet 2 circuit supporting standard TrueAlarm sensors
• Extended Wiring Margins: Maintains three 3 Amp IDNAC signaling loops allowing runs up to 3 times farther than conventional circuits
• Automated System Sweeps: Natively handles TrueAlert ES diagnostic walkthrough routines and silent self-testing cycles

Best Price Guaranteed

Description

The Simplex 4100-5313 EPS Card is an essential, high-performance master controller bay assembly chassis engineered to handle central data evaluation, primary power regulation, and intelligent addressable device loops for Simplex 4100ES safety networks. Operating on an international high-voltage main input, this comprehensive hardware package houses a 32-bit processing core, a text-based operator interface display panel, and an Enhanced Power Supply (EPS) module. By combining addressable sensor communications and intelligent signal power draw into a pre-configured bay chassis, the Simplex 4100-5313 EPS Card provides a highly reliable foundation for enterprise-level commercial, healthcare, and industrial property layouts.

Technical Specifications Table

Model Assignment 4100-5313 (TrueAlarm ES Master Controller Bay & EPS+ Assembly)
Manufacturer Family 4100ES Addressable Fire Detection Series by Simplex (Johnson Controls)
Country of Origin Mexico
Input Supply Power 220 VAC to 240 VAC (+10% / -15% tolerance limits), 50/60 Hz single phase
Nominal Output Voltage Regulated 29 VDC output during active alarm periods (even on battery standby)
Total Power Delivery 9.0 Amps total continuous output current for Special Application appliances
On-Board IDNet 2 Capacity 250 Addressable monitor and control points intermixed over a single wire pair
IDNet 2 Loop Setup 1 Electrically isolated output channel equipped with dual short-circuit isolation loops
IDNAC SLC Channels 3 Independent 3.0 Amp addressable notification line loops
Programmable Auxiliary Output 1 Selectable 2 Amp reverse-polarity channel (Configurable for AUX or SNAC)
Operator Interface Display Monochrome 2-line x 40-character backlit LCD panel with custom status keys
Battery Charger Capacity Temperature-compensated dual-rate charger; handles up to 110 Ah battery banks
Field Wire Constraints Heavy-duty terminal blocks supporting wire lines from 18 AWG to 12 AWG
Operating Temperature 32°F to 120°F (0°C to 49°C) certified strictly for indoor vertical mounting
Relative Humidity Limit Up to 93% RH non-condensing moisture boundaries at 90°F (32°C)
Agency List Compliance UL 864 Listed, ULC Listed, FM Approved, CSFM Certified, NYC Fire Dept Approved

⚙️ Engineering & Architecture Resources

Verify system loop voltage drops, line-to-line capacitance limits, and remote transponder communication routing mandates in accordance with national NFPA 72 Fire Alarm Code Standards before executing loop wiring parameters for the Simplex 4100-5313 EPS Card infrastructure.

📥 Download Official Technical Submittal Sheet (S4100-0100)

Regulated 29 VDC Switching Efficiency & Flexible Class B T-Tapped Wiring Savings

The core electrical benefit of integrating the comprehensive Simplex 4100-5313 EPS Card chassis is its advanced regulated DC-DC converter output. While conventional power supplies lose line current and experience severe voltage drops when switching over to backup battery cells, this enhanced supply platform uses an ultra-efficient switching layout that maintains a minimum 29 VDC source voltage across your loops. This steady source voltage means your addressable signaling lines can support wire runs up to two to three times farther than traditional loops, utilize smaller cable gauges, and support more appliances per SLC, resulting in massive material cost savings during facility construction.

Additionally, because the main board acts as a centralized addressable gateway, the advanced engineering features of the master panel layout allow the hardware path to integrate with external sub-cards. The onboard pre-installed IDNet 2 communication card evaluates device responses through a software filtering process, tracking individual sensor parameters every four seconds to eliminate false alarms from floating dust or aging components. When Class B branch routing is chosen for the loops, installers can completely T-tap the wiring grid inside the cabinet frame. This removes the rigid pigtail and series limits of conventional lines, allowing engineers to deploy the Simplex 4100-5313 EPS Card network and add Virtual NAC zones via simple panel programming scripts without pulling new structural conduits.

Beyond standard data management, the overall terminal layout of the Simplex 4100-5313 EPS Card is fully shielded against electrical transients and electromagnetic fields. This defensive shielding ensures that the communication loops remain totally stable even when routed through high-voltage industrial utility rooms or conduits sharing tight spaces with auxiliary facility systems. The processing core automatically balances loop impedances in real-time, matching variations in field wiring properties to maintain high-integrity digital communications across all interconnected terminal devices.

  • Dual short circuit loop isolation: Built with two independent short-circuit separating loops, ensuring a field wire fault on one loop branch doesn’t take down other devices.
  • Temperature-Compensated Battery Charger: Built with an intelligent charger that automatically changes its dual-rate charging curves based on temperature, keeping large external batteries up to 110 Ah healthy.
  • Module Level Ground Fault Searches: Features smart software commands that help field technicians isolate and trace tricky ground faults directly to a specific circuit module card.
  • Front-Accessible Ethernet Diagnostics: Built with an easily accessible service port on the board to speed up uploads, downloads, and custom firmware changes via a laptop connection.

Frequently Asked Questions (FAQ)

Q1: What exactly does the complete Simplex 4100-5313 product include out of the box?
A: The 4100-5313 is a complete master controller bay assembly. It includes the 32-bit master CPU processor card, a monochrome 2×40 text display interface with status switches, a 240V Enhanced Power Supply (EPS) module, and a built-in 250-point IDNet 2 card slot.

Q2: Why is this module designated as an EPS power supply rather than an older power supply?
A: The newer EPS architecture integrates advanced switching regulation to maintain a steady 29 VDC output on battery power, and it replaces legacy single-loop links with high-speed isolated IDNet 2 module cards.

Q3: Can this 240V master bay package be wired to standard American 120 VAC main lines?
A: No. The 4100-5313 model variant is specifically engineered with transformers designed to connect to international 220-240 VAC input voltages.

Q4: What is the maximum individual device address capacity pre-supported by this core assembly?
A: The on-board IDNet 2 module provides a single isolated loop output that supports up to 250 addressable monitor or control points intermixed over the same pair of wires.

Q5: Does this master controller support T-tapped loop wiring on branch circuits?
A: Yes, absolutely. When deploying standard Class B circuit loops, you can freely T-tap the field lines, which simplifies routing layout profiles and dramatically drops your copper wire installation costs.

Q6: What happens to active notification test routines if a real fire alarm condition triggers during testing?
A: The panel’s internal program is designed with an automated priority override. If a real alarm is verified, any active WALKTEST or diagnostic script is instantly killed to activate emergency evacuation protocols.

Q7: What is the exact physical origin and structural profile of this primary chassis component?
A: This genuine Simplex fire alarm spare part is manufactured to strict life-safety compliance parameters in Mexico and features a standard multi-block panel frame layout.

Reviews

There are no reviews yet.

Be the first to review “Simplex 4100-5313 EPS Card Master Controller Bay Assembly”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581