Simplex 49AV-WRF Addressable Sounder with Strobe

• Manufacturer Portfolio: Simplex Fire Products by Johnson Controls
• Advanced Loop Interfacing: Individually addressed TrueAlert ES wall-mount multi-candela horn/strobe appliance
• IDNAC SLC Optimization: Line-powered directly via a two-wire circuit maintaining a regulated 29 VDC loop
• Multi-Candela Versatility: Six selectable strobe intensity outputs (15, 30, 75, 110, 135, or 185 candela)
• Smart Programming Matrix: Strobe settings can be changed remotely from the FACU panel or manually jumper selected
• Dual-Element Logic: Horn alerts are controlled completely separate from strobes on the same single two-wire pair
• Revolutionary Testing Protocol: Self-Test Mode runs onboard diagnostic sensors to check horn and flash output automatically
• Diagnostic Magnet Test: Magnet activation sequentially pulses the device LED to display its exact loop address node
• Flexible Circuit Topology: Wiring supervision allows T-tapped branch connections for Class B layouts to save copper
• High-Impact Shell Design: Flame-retardant red thermoplastic housing featuring high-contrast white “FIRE” lettering
• Regulatory Safety Compliance: Certified to UL 1971 (Hearing Impaired Signaling), UL 464, and ULC-S525 Standards

Best Price Guaranteed

Description

The Simplex 49AV-WRF Addressable Sounder with Strobe is a next-generation TrueAlert ES audible/visible (A/V) notification appliance engineered to provide high-integrity emergency signaling within modern commercial, industrial, and institutional safety infrastructures. Controlled and supervised directly over an intelligent IDNAC Signaling Line Circuit (SLC), this advanced wall-mount unit combines a clear xenon flash strobe and an efficient electronic horn chamber into a sleek, low-profile thermoplastic assembly.

Technical Specifications Table

Model Assignment 49AV-WRF (TrueAlert ES Addressable Wall Multi-Candela Horn/Strobe)
Manufacturer Family TrueAlert ES Addressable Appliances by Simplex (Johnson Controls)
Country of Origin Mexico
Loop Communication Protocol IDNAC Signaling Line Circuit (SLC) Allocation (1 Device Address Node)
Channel Wiring Capacity Maximum of 127 addresses per SLC loop | 139 maximum unit loads
Operating Loop Voltage 23 VDC to 31 VDC Special Application (Regulated 29 VDC from host controller)
Supervisory Loop Current 1 Unit Load (Equivalent to 0.8 mA maximum control panel current draw)
Strobe Candela Settings Field or Panel Selectable: 15 cd, 30 cd, 75 cd, 110 cd, 135 cd, or 185 candela
Strobe Lens Architecture High-output 24 VDC xenon flash tube with a clear, impact-resistant optical lens
Strobe Flash Synchronization Locked at a steady 1 Hz flash rate across all devices sharing a common circuit run
Maximum RMS Current Draw 59 mA (15cd) | 67 mA (30cd) | 107 mA (75cd) | 139 mA (110cd) with horn on high continuous
Horn Audio Output (High) 94.1 dBA (Anechoic Chamber) | 90.1 dBA (UL 464 Reverberant Room) at 10 ft
Horn Audio Output (Low) 88.1 dBA (Anechoic Chamber) | 83.6 dBA (UL 464 Reverberant Room) at 10 ft
Acoustic Range Frequency 2400 to 3700 Hz frequency sweep modulated at a clear 120 Hz response rate
Wiring Terminal Block Plate-mounted screw blocks supporting solid or stranded lines from 18 to 12 AWG
Operating Temperatures 32°F to 122°F (0°C to 50°C) intended exclusively for indoor terminal applications
Humidity Resilience Window 10% to 93% RH at 104°F (40°C) non-condensing moisture boundaries
Chassis Scale Dimensions 5-1/8″ H x 5″ W x 2-5/8″ D (130 mm x 127 mm x 67 mm) | Weight: 0.75 lbs
Agency List Compliance UL 1971 Listed, UL 464 Listed, ULC Listed, FM Approved, CSFM Certified

⚙️ Engineering & Architecture Resources

Verify polar light distribution plots, Class A circuit constraints, and legacy addressable panel compatibility matrices in the official technical submittal sheet: S49AV-0001.pdf.

📥 Download Official Technical Datasheet

TrueAlert ES Operation Edge & Automated Self-Test Diagnostic Advantages

The defining operational benefit of the Simplex 49AV-WRF Addressable Sounder with Strobe is its integration with TrueAlert ES technology running on modern IDNAC loops. Unlike traditional notification circuits where an entire wire branch must be tested manually by field crews, the 49AV-WRF features an advanced, automated Self-Test mode. Armed with internal optical and acoustic sensors, the device triggers its own strobe flash and horn mechanics briefly and reports the operational results back to the central fire alarm control panel automatically.

  • Six-Tier Candela Adjustability: Offers full flexibility across changing room layouts by allowing the strobe intensity to be set to 15, 30, 75, 110, 135, or 185 cd via backend jumper pins or central panel commands.
  • Latching Cadence Control: The horn operates completely independently from visible strobes on the same loop, responding instantly to panel commands for Temporal Code 3, March Time (selectable at 20, 60, or 120 BPM), or continuous tones.
  • Front-Accessible Wiring Terminal Plate: Features a design where the backplate wiring can be terminated completely before mounting the main electronic housing, protecting sensitive components during rough-in construction.
  • Polarized Supervision Network: Built with a diode-polarized configuration to enforce strict loop wiring supervision extending all the way into the device’s electronic circuit, ensuring any open faults are reported instantly.

Frequently Asked Questions (FAQ)

Q1: How can an inspector verify the selected strobe candela rating without detaching the module?
A: The module features an integrated strobe intensity viewing slot on the side of the housing cover, allowing inspectors to easily check the active candela output at a glance.

Q2: Does this combination appliance require separate wiring loops for the horn and the strobe elements?
A: No. Operating on an IDNAC two-wire loop, both appliances share a single pair of wires, allowing the panel to silence the horn independently (“on-until-silenced”) while the strobe remains flashing (“on-until-reset”).

Q3: What unique workflow advantage does the TrueAlert ES Self-Test feature offer?
A: It utilizes built-in internal sensors to physically check the sounder and flash mechanisms and report results back to the panel, allowing for automated diagnostic sweeps without manual room-by-room walkthroughs.

Q4: Is an independent auxiliary 24V power line circuit run required to power this module?
A: No. Operating current, system commands, and diagnostic telemetry are drawn entirely over the two-wire IDNAC circuit, which supplies a constant, regulated 29 VDC output loop even during battery backup.

Q5: Can the acoustic sound level be lowered for small office spaces or echoing stairwells?
A: Yes. You can toggle the output volume level from High down to Low via internal configuration switches (providing an absolute 5 dBA reduction), or install an optional mechanical sound damper.

Q6: Which central fire alarm control panels provide native support for this addressable appliance?
A: It integrates natively with modern addressable Simplex control units equipped with IDNAC channels, including the 4007ES, 4010ES, and 4100ES platform series.

Q7: What type of box mounting does this red wall combination unit support?
A: The flexible mounting template attaches securely to standard single-gang, double-gang, or 4-inch square electrical backboxes for easy surface or semi-flush wall installation.

Reviews

There are no reviews yet.

Be the first to review “Simplex 49AV-WRF Addressable Sounder with Strobe”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581