Simplex 4099-9005 Addressable Manual Call Point (Dual-Action Break-Glass Type)

The Simplex 4099-9005 Addressable Manual Call Point is a commercial-grade, dual-action pull station utilizing premium break-glass technology to prevent malicious false alarms. Made in Mexico and fully UL listed, it features an integrated Individual Addressable Module (IAM) that communicates real-time diagnostic parameters over a single-pair IDNet or MAPNET II loop protocol.

  • Core Engineering Data: Brand: Simplex | Model Number: 4099-9005 | Origin: Mexico | Certification: UL Listed
  • Activation Interface: Push-Glass Hammer Actuation with Latching Downward Pull Handle
  • Loop Interfacing: Single-Address Allocation compatible with IDNet and MAPNET II SLC Lines
  • Compliance Layer: Fully ADA-Compliant Pull Height Setup meeting NFPA 72 Standards
Best Price Guaranteed

Description

The Simplex 4099-9005 Addressable Manual Call Point is an enterprise-grade life safety component engineered to provide reliable human-initiated emergency signaling within demanding commercial and industrial environments. Constructed from high-impact red Lexan polycarbonate, this heavy-duty pull station combines a classic aesthetic with an integrated Individual Addressable Module (IAM)[cite: 21]. Operating over a two-wire addressable configuration, the 4099-9005 transmits digitized device status and precise location pinpointing directly to the host command console every four seconds, offering a highly secure life safety milestone for master system layouts[cite: 21].

Technical Specifications

Model Number 4099-9005 (Double Action, Break-Glass Operation, English Language)[cite: 21]
Product Line IDNet Communicating Peripherals by Simplex (Johnson Controls)[cite: 21]
Country of Origin Mexico[cite: 21]
SLC Communication Loop IDNet Addressable Network Loop (Also backward compatible with MAPNET II)[cite: 21]
Operating Loop Voltage 24 VDC Nominal (Power-limited, drawn directly from signaling circuit lines)[cite: 21]
Standby Current Draw < 250 µA internal consumption limit[cite: 21]
Active Alarm Current 6.0 mA to 8.0 mA operational threshold[cite: 21]
Internal Addressing Method 8-Position manual DIP switch protected beneath a resealable security label[cite: 21]
Wiring Terminal Block Heavy-duty screw terminals accepting 18 AWG to 14 AWG (0.82 mm² to 2.08 mm²) lines[cite: 21]
Operating Temperatures 32°F to 120°F (0°C to 49°C) intended exclusively for indoor terminal applications[cite: 21]
Relative Humidity Tolerance Up to 93% RH at 100°F (38°C) non-condensing boundaries[cite: 21]
Chassis Dimensions 5.0″ H x 3.75″ W x 1.0″ D (127 mm x 95 mm x 25 mm)[cite: 21]
Agency Certifications UL Listed to Standard 38, ULC Listed, FM Approved, CSFM Certified, NYC MEA Accepted[cite: 21]

⚙️ Engineering & Architecture Resources

Verify terminal layouts, loop capacitance limitations, and structural backbox options in the official technical reference guide: S14099-0001.pdf.

📥 Download Official Technical Datasheet

Tamper-Resistant Break-Glass Operation & System Integrity Monitoring

The operational framework of the Simplex 4099-9005 macro-architecture requires two independent physical actions to initiate a system-wide emergency alarm condition[cite: 21]. To actuate the loop, an occupant must first use the attached hammer assembly to fracture the front security glass plate, which uncovers the internal recessed manual handle[cite: 21]. Pulling the clean white lever down immediately trips the internal alarm mechanism, sending a latching confirmation flag back to the fire panel while physically protruding outward from the housing to serve as a bright, visible indicator for inspecting safety response teams[cite: 21].

This dual-criteria process effectively cuts down on malicious building vandalism, casual impacts, and costly commercial nuisance alarms[cite: 21]. The unit contains a low-profile terminal setup containing embedded supervision logic that constantly tracks the electrical status of the wiring loop, instantly alerting the central workstation if a branch cable breaks or a device is disconnected from the wall[cite: 21]. Following an active event, resetting the call point is simple: maintenance crews open the front cover using a traditional, tamper-resistant Simplex “B” key, clear out the fractured debris, slide a fresh replacement glass pane into the tracking guides, and re-latch the internal handle assembly into place[cite: 21].

  • Dual-Phenomena Break-Glass Activation: Offers high security against vandalism, making it perfect for layout placements across hospitals, public schools, and transport terminals[cite: 21].
  • Integrated Single-Pair Loop Wiring: Draws data and operating power concurrently from a single wire pair over the addressable circuit, minimizing material costs[cite: 21].
  • Tamper-Proof Reset Architecture: Utilizes a standard key lock cylinder matched to central fire alarm enclosure keys to restrict reset functions to certified personnel[cite: 21].
  • Flexible Mounting Options: Adapts easily to surface-mounted setups via matching red steel or cast boxes, semi-flush terminal plates, or custom retrofit adapter frames[cite: 21].

Frequently Asked Questions (FAQ)

Q1: How does a dual-action break-glass design eliminate nuisance commercial trips?
A: Unlike standard single-action configurations that trip from an accidental bump, the 4099-9005 requires users to physically break the front glass barrier before the alarm pull lever can be accessed[cite: 21].

Q2: Does this manual call point require a separate 24V auxiliary power connection?
A: No. Operating currents, digital processing power, and polling commands are drawn entirely over the two-wire IDNet addressable circuit, significantly reducing installation labor[cite: 21].

Q3: Which specialized central command control panels support this peripheral model?
A: It is fully compatible with modern intelligent Simplex platforms, including the 4007ES, 4010ES, and 4100ES network panel portfolios[cite: 21].

Q4: How do safety teams perform routine testing without breaking physical glass panes?
A: Field testing is easily completed by opening the outer face housing with a standard Simplex “B” reset key, which activates the internal micro-switch electronically without breaking the glass window[cite: 21].

Q5: What are the primary backbox mounting options for a new building construction layout?
A: For surface installations, it mounts smoothly to a 2975-9178 steel box or a 2975-9022 cast aluminum box[cite: 21]. It also accommodates standard single-gang or double-gang recess box variants with matching adapter trims[cite: 21].

Q6: Is a plastic break-rod mandatory for this call point to operate properly?
A: No. The internal break-rod functions purely as an optional visual deterrent; the call point remains completely operational and code-compliant with or without it installed[cite: 21].

Q7: What material makes up the outer housing framework and what is its color code?
A: The chassis is manufactured from high-impact, flame-retardant white Lexan polycarbonate finished in a brilliant signal red tone with stark, high-contrast raised white lettering[cite: 21].

Reviews

There are no reviews yet.

Be the first to review “Simplex 4099-9005 Addressable Manual Call Point (Dual-Action Break-Glass Type)”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581