Simplex 4098-9754 Addressable Multi-Sensor

The Simplex 4098-9754 Addressable Multi-Sensor with 4098-9789 Base integrates high-performance photoelectric smoke sensing and thermal thermistor technology in one low-profile housing. Made in Mexico and fully UL listed, it utilizes TrueSense correlation logic to identify hot, fast-flaming fires rapidly while reporting comprehensive data using only a single address on your intelligent IDNet loop.

  • Core Engineering Data: Brand: Simplex | Model Bundle: 4098-9754 + 4098-9789 | Origin: Mexico
  • Sensor Architecture: Combined Photoelectric Light-Scattering & Fast-Response Thermistor
  • Single-Address Footprint: Reports dual sub-points through one intelligent IDNet loop node
  • Safety Standards: UL 268 Listed, ULC Listed, FM Approved, MEA NYC Accepted
Best Price Guaranteed

Description

The Simplex 4098-9754 Addressable Multi-Sensor combined with the 4098-9789 Addressable Base forms an advanced, dual-technology fire detection kit engineered to deliver maximum life-safety security across high-value real estate layouts. By integrating a high-performance photoelectric smoke chamber alongside an ultra-precise thermal thermistor element into a single structural housing, this intelligent peripheral achieves exceptional early warning tracking capabilities. It represents an elite engineering asset designed to safeguard commercial spaces, healthcare facilities, and complex infrastructure installations with absolute monitoring accuracy.

Technical Specifications

Sensor Model 4098-9754 (TrueAlarm Analog Photoelectric & Thermal Multi-Sensor Head)
Base Model Compatibility 4098-9789 (Addressable Mounting Base with External Wired Leads)
Technology Portfolio Simplex TrueAlarm & TrueSense Fire Detection by Johnson Controls
Country of Origin Mexico
Signaling Loop Protocol IDNet Two-Wire Addressable Communications (Single-Address Allocation)
Operating Loop Voltage 24 to 40 VDC (Power-limited, drawn directly from addressable signaling loop)
Smoke Sensitivity Range Programmable from 0.2% to 3.7% obscuration per foot via central console panel
Thermal Fixed Thresholds Selectable at 135°F (57.2°C) or 155°F (68°C)
Rate-of-Rise (ROR) Detection Panel-selectable at either 15°F/min or 20°F/min (8.3°C/min or 11.1°C/min)
Maximum Air Velocity Up to 4,000 ft/min (0 to 1,220 m/min) operational baseline limits
Durable Certifications UL 268 Standard Listed, ULC Listed, FM Approved, MEA NYC Accepted, CSFM Certified

⚙️ Engineering & Architecture Resources

Verify system sub-point reporting parameters, loop calculations, and electrical base maps in the official manufacturer technical document: S4098-0024-7.pdf.

📥 Download Official Technical Datasheet

TrueSense Correlation Logic & Intelligent Dual-Phenomena Detection

The standout advantage of the Simplex 4098-9754 Addressable Multi-Sensor lies in its patented TrueSense algorithmic correlation technology. Rather than processing smoke scattering metrics and environmental temperature rises as independent isolated variables, the host fire alarm control panel continuously evaluates their combined covariance trends. This mathematical relationship lets the system identify fast-acting, hot-flaming chemical or electrical fires significantly faster than either a standalone photoelectric head or heat sensor could manage on its own, providing a massive safety advantage during critical early-stage building emergencies.

Despite its dual-detection capability, the 4098-9754 utilizes specialized point programming that allows it to communicate both thermal and smoke data tracks across the loop while occupying only a single address on your central IDNet card layout. This single-address footprint preserves communication loop bandwidth, optimizing your project parameters and lowering total software expansion card costs. Additionally, built-in environmental drift compensation actively filters out slow, drifting ambient interferences like atmospheric dust or component aging, maintaining an accurate reference point to minimize false alerts.

  • TrueSense Covariance Analysis: Intelligently bridges smoke and heat trends, maximizing fire containment speeds while delivering elite immunity against costly commercial nuisance trips.
  • Permanently Anchored Loop Addresses: The 4098-9789 base houses the addressable DIP switch micro-electronics internally, meaning sensor heads can be detached for localized maintenance without breaking software loop addresses.
  • Multi-Stage Early Warning Warning: Allows system managers to program multi-tier responses—such as initiating a low-level localized supervisory alert at 0.2% smoke obscuration and a full building evacuation at 2.5%.

Frequently Asked Questions (FAQ)

Q1: What are the main benefits of using a combo Simplex 4098-9754 multi-sensor?
A: It houses independent photoelectric and thermal tracking modules inside a single ceiling enclosure, running TrueSense correlation processing to discover high-heat flaming fires substantially faster than standard single-element sensors.

Q2: Does this device require two separate loop addresses on my central fire control panel?
A: No. Through specialized multi-point reporting architecture on Simplex IDNet loops, the 4098-9754 communicates both comprehensive smoke and heat analytics using only one address on the circuit.

Q3: Are both the multi-sensor head and the addressable base included together?
A: Yes. This SKU functions as a pre-packaged field solution combining the 4098-9754 multi-sensor head alongside the 4098-9789 addressable wiring base for a clean, out-of-the-box installation.

Q4: Can I configure customized thermal alarm parameters on this device?
A: Yes, absolutely. The host panel allows individual customization per device, enabling you to select fixed-temperature sensing at 135°F or 155°F, or combine fixed thresholds with selectable rate-of-rise tracking.

Q5: How does the integrated base LED indicator verify loop operational status?
A: During routine conditions, the integral red LED pulses softly to confirm clean polling data streams from the control panel. If a serious fire condition or localized hardware trouble is detected, the LED latches steady on.

Q6: Can this multi-sensor head be utilized as an independent temperature monitor?
A: Yes. It can be custom-programmed as a local utility device to track baseline extremes from 32°F to 122°F, delivering freeze warnings or tracking major HVAC plant failures before building damage occurs.

Q7: Which specific central fire panels natively support this addressable peripheral?
A: It interfaces smoothly with all core addressable IDNet platforms, including the modern Simplex 4007ES, 4010ES, and 4100ES fire control units.

Reviews

There are no reviews yet.

Be the first to review “Simplex 4098-9754 Addressable Multi-Sensor”

Your email address will not be published. Required fields are marked *

We Don't Just Sell Products, We Deliver Complete Solutions.

From planning to handover – Loop Shop is your single point MEP partner.

Expert Consultant

Get advised from our MEP Specialist

Supply & Installation

Professional installation by certified engineers

Testing & Commissioning

Ensuring system works perfectly

After Sales Support

AMC & 24/7 technical support

Have Project in Mind?

Get free and consultations and quotation for your project. 

Need Help Deciding?

Leave your number and we'll contact you with the best offer.


Notice: ob_end_flush(): Failed to send buffer of zlib output compression (0) in /home/loopshop/public_html/wp-includes/functions.php on line 5581